CoChat

Intravenous Safety and Pharmacokinetics of a Novel Dimerizer Drug, AP1903, in Healthy Volunteers

Iuliucci, John D., Oliver, Stuart D., Morley, Steve, Ward, Chris, Ward, Janet, Dalgarno, David, Clackson, Tim, Berger, Harvey J. · 2001 · The Journal of Clinical Pharmacology
Cited by 125

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

AP1903 is a novel gene‐targeted drug that is being developed for use in drug‐regulated cell therapies. An intravenous, single‐blind, placebo‐ and saline‐controlled, ascending‐dose study was performed to evaluate the safety, tolerability and pharmacokinetics of AP1903. Twenty‐eight normal healthy male volunteers were randomized into five dosage groups of AP1903 (0.01, 0.05, 0.1, 0.5, and 1 mg/kg). Within each group, 4 volunteers received a single dose of AP1903, 1 volunteer received an equal volume of placebo, and 1 received an equal volume of normal saline. The only exception was in the 0.5 mg/kg group, in which 4 volunteers were dosed: 3 received AP1903 and 1 received normal saline. All dosages were administered as intravenous infusions over 2 hours. Clinical safety parameters were monitored, and serial blood and urine samples were collected for analysis of AP1903. No drug‐related adverse events were observed at any of the dose levels with the possible exception of facial flushing in 1 volunteer at the 1.0 mg/kg dose level. AP1903 plasma levels were directly proportional to the administered dose, with mean C max values ranging from approximately 10 to 1275 ng/mL over the 0.01 to 1.0 mg/kg dose range. Following the infusion period, blood concentrations revealed a rapid distribution phase, with plasma levels being reduced to approximately 18%, 7%, and 1% of the maximal concentration at 0.5, 2, and 10 hours postdose, respectively. AP1903 was shown to be safe and well tolerated at all dose levels and demonstrated a favorable pharmacokinetic profile at doses well above the anticipated therapeutic dose.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/00912700122010771

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

  • Redesigning an FKBP–ligand interface to generate chemical dimerizers with novel specificity

    Clackson, T., Yang, W., Rozamus, L. W., Hatada, M., Amara, J. F., Rollins, C. T., Stevenson, L. F., Magari, S. R., Wood, S. A., Courage, N. L., et al. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.18.10437 · Cited by 558 · cited 3×

    “This high potency is consistent with the in vitro affinity and selectivity of AP1903, which was engineered to bind tightly to the target FKBP fusion protein while binding minimally to the abundant natural FKBP.14 In the clinical setting, cancer patients will receive T cell–depleted BMT. Donor lymphocytes will be colle…”
    BackgroundResultSelf-citation

Show all 1 references

Cited by

Metadata

Authors
Iuliucci, J. D., Oliver, S. D., Morley, S., Ward, C., Ward, J., Dalgarno, D., Clackson, T., & Berger, H. J.
Venue
The Journal of Clinical Pharmacology
Publisher
Wiley
Published
2001-08
Volume
41
Issue
8
Pages
870-879
ISSN
  • 0021-9754 (ISSN-L)
  • 0091-2700
  • 1552-4604
OpenAlex
W2085424263
Cited by
125
References
1
FWCI
2.59
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.