CoChat

Evaluation and Comparison of Artificial Intelligence Vision Aids: Orcam MyEye 1 and Seeing AI

Granquist, Christina, Sun, Susan Y., Montezuma, Sandra R., Tran, Tu M., Gage, Rachel, Legge, Gordon E. · 2021 · Journal of Visual Impairment & Blindness
Cited by 64

The DOI matches its Crossref record.

Abstract

Introduction: We compared the print-to-speech properties and human performance characteristics of two artificial intelligence vision aids, Orcam MyEye 1 (a portable device) and Seeing AI (an iPhone and iPad application). Methods: There were seven participants with visual impairments who had no experience with the two reading aids. Four participants had no light perception. Two individuals with measurable acuity and one with light perception were tested while blindfolded. We also tested performance with text of varying appearance in varying viewing conditions. To evaluate human performance, we asked the participants to use the devices to attempt 12 reading tasks similar to activities of daily living. We assessed the ranges of text attributes for which reading was possible, such as print size, contrast, and light level. We also assessed if individuals could complete tasks with the devices and measured accuracy and completion time. Participants also completed a survey concerning the two aids. Results: Both aids achieved greater than 95% accuracy in text recognition for flat, plain word documents and ranged from 13 to 57% accuracy for formatted text on curved surfaces. Both aids could read print sizes as small as 0.8M (20/40 Snellen equivalent, 40 cm viewing distance). Individuals successfully completed 71% and 55% ( p = .114) of tasks while using Orcam MyEye 1 and Seeing AI, respectively. There was no significant difference in time to completion of tasks ( p = .775). Individuals believed both aids would be helpful for daily activities. Discussion: Orcam MyEye 1 and Seeing AI had similar text-reading capability and usability. Both aids were useful to users with severe visual impairments in performing reading tasks. Implications for Practitioners: Selection of a reading device or aid should be based on individual preferences and prior familiarity with the platform, since we found no clear superiority of one solution over the other.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/0145482x211027492

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 64

Metadata

Authors
Granquist, C., Sun, S. Y., Montezuma, S. R., Tran, T. M., Gage, R., & Legge, G. E.
Venue
Journal of Visual Impairment & Blindness
Published
2021-07
Volume
115
Issue
4
Pages
277-285
ISSN
  • 0145-482X (ISSN-L)
  • 1559-1476
OpenAlex
W3185101217
Cited by
64
References
0
FWCI
10.66
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evaluation and Comparison of Artificial Intelligence Vision Aids: Orcam MyEye 1 and Seeing AI. https://app.cochat.ai/papers/10.1177/0145482x211027492
The paper
Granquist, C., Sun, S. Y., Montezuma, S. R., Tran, T. M., Gage, R., & Legge, G. E. (2021). Evaluation and Comparison of Artificial Intelligence Vision Aids: Orcam MyEye 1 and Seeing AI. Journal of Visual Impairment & Blindness. https://doi.org/10.1177/0145482x211027492

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.