Identifying Variables Associated With Inaccurate Self-Monitoring of Blood Glucose: Proposed Guidelines to Improve Accuracy
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
PURPOSE this study was conducted to evaluate patients' proficiency in self-monitoring of blood glucose (SMBG). METHODS Diabetes nurse educators in 4 suburban Minneapolis clinic sites surveyed the SMBG training/cure practices of 280 patients with type 1 and type 2 diabetes. Participant SMBG technique was measured by direct observation. Participants performed a finger puncture and used their own meters to measure the first blood sample. A second sample was measured on the HemoCue B Glucose analyzer, and a third sample was used to measure hemoglobin. The series of tests were then repeated. If either of the 2 glucose tests was more than 15% from the HemoCue value, participants were reeducated about the manufacturer's suggested procedure. RESULTS Of the 280 participants, 19% had blood glucose test results greater than the 15% limit for meter accuracy. After reeducation, 69% of those who had initially failed achieved acceptable results. The most significant problems were lack of periodic meter technique evaluation, difficulty using wipe meters, incorrect use of control solutions, lack of hand washing even when observed, and unclean meters. CONCLUSIONS As a result of the study, guidelines were subsequently developed to evaluate meter accuracy in an outpatient setting. Further effort is needed to establish standards for evaluating SMBG.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Self-monitoring of blood glucose by adults with diabetes in the United States population
Harris, M. I., Cowie, C. C., & Howie, L. J. (1993) · Diabetes Care · doi:10.2337/diacare.16.8.1116 · Cited by 158
Cited by
DiMeglio, L. A., Acerini, C. L., Codner, E., Craig, M. E., Hofer, S. E., Pillay, K., & Maahs, D. M. (2018) · Pediatric Diabetes · doi:10.1111/pedi.12737 · Cited by 604
Assessing Glycemia in Diabetes Using Self-monitoring Blood Glucose and Hemoglobin A 1c
Saudek, C. D., Derr, R. L., & Kalyani, R. R. (2006) · JAMA · doi:10.1001/jama.295.14.1688 · Cited by 373
Assessment and monitoring of glycemic control in children and adolescents with diabetes
Rewers, M., Pihoker, C., Donaghue, K., Hanas, R., Swift, P., & Klingensmith, G. J. (2009) · Pediatric Diabetes · doi:10.1111/j.1399-5448.2009.00582.x · Cited by 342
Assessment and monitoring of glycemic control in children and adolescents with diabetes
Rewers, M. J., Pillay, K., de Beaufort, C., Craig, M. E., Hanas, R., Acerini, C. L., & Maahs, D. M. (2014) · Pediatric Diabetes · doi:10.1111/pedi.12190 · Cited by 316
Glucose Measurement: Confounding Issues in Setting Targets for Inpatient Management
Dungan, K., Chapman, J., Braithwaite, S. S., & Buse, J. (2007) · Diabetes Care · doi:10.2337/dc06-1679 · Cited by 292
Metadata
- Authors
- Bergenstal, R., Pearson, J., Cembrowski, G. S., Bina, D., Davidson, J., & List, S.
- Venue
- The Diabetes Educator
- Publisher
- SAGE Publications
- Published
- 2000-11
- Volume
- 26
- Issue
- 6
- Pages
- 981-989
- ISSN
- 0145-7217 (ISSN-L)
- 1554-6063
- OpenAlex
- W2113308910
- Cited by
- 108
- References
- 1
- FWCI
- 1.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Identifying Variables Associated With Inaccurate Self-Monitoring of Blood Glucose: Proposed Guidelines to Improve Accuracy. https://app.cochat.ai/papers/10.1177/014572170002600610
- The paper
- Bergenstal, R., Pearson, J., Cembrowski, G. S., Bina, D., Davidson, J., & List, S. (2000). Identifying Variables Associated With Inaccurate Self-Monitoring of Blood Glucose: Proposed Guidelines to Improve Accuracy. The Diabetes Educator. https://doi.org/10.1177/014572170002600610
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.