Percutaneous Endoscopic Gastrostomies: A Prospective Evaluation and Review of the Literature
The DOI matches its Crossref record.
Abstract
The results of the first 55 consecutive percutaneous endoscopic gastrostomies (PEGs) that were performed over an 18‐month period in a tertiary care center are presented. We followed these cases prospectively to assess the morbidity, mortality, staff acceptance, short‐ and long‐term complications, and cost effectiveness of the technique. Fifty‐one (93%) were successful with no mortality. Long‐term morbidity included 6/ 55 (11%) tube extrusions; 5/55 (9%) cellulitis around the catheter site; 5/55 (9%) aspiration pneumonias; and 2/55 (3.6%) clogged tubes requiring replacement. Morbidity was considered minor and easily dealt with in all but five instances (9%) where more prolonged treatment was required. A review of the literature including other techniques used for percutaneous gastrostomy is also presented. It is concluded that percutaneous gastrostomies are relatively safe, cost‐effective, and should be given first consideration for long‐term enteral therapy in appropriate patients. (Journal of Parenteral and Enteral Nutrition 10:155–159, 1986)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Park, R. H., Allison, M. C., Lang, J., Spence, E., Morris, A. J., Danesh, B. J., Russell, R. I., & Mills, P. R. (1992) · BMJ · doi:10.1136/bmj.304.6839.1406 · Cited by 427
Endoscopic versus operative gastrostomy: final results of a prospective randomized trial
Stiegmann, G. V., Goff, J. S., Silas, D., Pearlman, N., Sun, J., & Norton, L. (1990) · Gastrointestinal Endoscopy · doi:10.1016/s0016-5107(90)70911-x · Cited by 226
Outcomes of Percutaneous Endoscopic Gastrostomy Among Older Adults in a Community Setting
Callahan, C. M., Haag, K. M., Weinberger, M., Tierney, W. M., Buchanan, N. N., Stump, T. E., & Nisi, R. (2000) · Journal of the American Geriatrics Society · doi:10.1111/j.1532-5415.2000.tb04779.x · Cited by 225
Kaw, M., & Sekas, G. (1994) · Digestive Diseases and Sciences · doi:10.1007/bf02087416 · Cited by 194
Grant, J. P. (1993) · Annals of Surgery · doi:10.1097/00000658-199302000-00011 · Cited by 193
Metadata
- Authors
- Kirby, D. F., Craig, R. M., Tsang, T., & Plotnick, B. H.
- Venue
- Journal of Parenteral and Enteral Nutrition
- Publisher
- Wiley
- Published
- 1986-03
- Volume
- 10
- Issue
- 2
- Pages
- 155-159
- ISSN
- 0148-6071 (ISSN-L)
- 1941-2444
- OpenAlex
- W2034461639
- Cited by
- 104
- References
- 0
- FWCI
- 7.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Percutaneous Endoscopic Gastrostomies: A Prospective Evaluation and Review of the Literature. https://app.cochat.ai/papers/10.1177/0148607186010002155
- The paper
- Kirby, D. F., Craig, R. M., Tsang, T., & Plotnick, B. H. (1986). Percutaneous Endoscopic Gastrostomies: A Prospective Evaluation and Review of the Literature. Journal of Parenteral and Enteral Nutrition. https://doi.org/10.1177/0148607186010002155
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.