Randomized Controlled Withdrawal Study of Upper Airway Stimulation on OSA: Short‐ and Long‐term Effect
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Objective: To assess the efficacy and durability of upper airway stimulation via the hypoglossal nerve on obstructive sleep apnea (OSA) severity including objective and subjective clinical outcome measures. Study Design: A randomized controlled therapy withdrawal study. Setting: Industry‐supported multicenter academic and clinical setting. Subjects: A consecutive cohort of 46 responders at 12 months from a prospective phase III trial of 126 implanted participants. Methods: Participants were randomized to either therapy maintenance (“ON”) group or therapy withdrawal (“OFF”) group for a minimum of 1 week. Short‐term withdrawal effect as well as durability at 18 months of primary (apnea hypopnea index and oxygen desaturation index) and secondary outcomes (arousal index, oxygen desaturation metrics, Epworth Sleepiness Scale, Functional Outcomes of Sleep Questionnaire, snoring, and blood pressure) were assessed. Results: Both therapy withdrawal group and maintenance group demonstrated significant improvements in outcomes at 12 months compared to study baseline. In the randomized assessment, therapy withdrawal group returned to baseline, and therapy maintenance group demonstrated no change. At 18 months with therapy on in both groups, all objective respiratory and subjective outcome measures showed sustained improvement similar to those observed at 12 months. Conclusion: Withdrawal of therapeutic upper airway stimulation results in worsening of both objective and subjective measures of sleep and breathing, which when resumed results in sustained effect at 18 months. Reduction of obstructive sleep apnea severity and improvement of quality of life were attributed directly to the effects of the electrical stimulation of the hypoglossal nerve.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Upper-Airway Stimulation for Obstructive Sleep Apnea
Strollo, P. J., Soose, R. J., Maurer, J. T., de Vries, N., Cornelius, J., Froymovich, O., Hanson, R. D., Padhya, T. A., Steward, D. L., Gillespie, M. B., et al. (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1308659 · Cited by 1,299 · cited 1×
“The current study uses a randomized treatment withdrawal study methodology to assess effectiveness and longer term durability of an Upper Airway Stimulation (UAS) device.(11) The first 46 patients successfully treated with UAS therapy 1 year after device implantation from a phase III trial cohort were randomized to ha…”
MethodSelf-citationCaples, S. M., Rowley, J. A., Prinsell, J. R., Pallanch, J. F., Elamin, M. B., Katz, S. G., & Harwick, J. D. (2010) · Sleep · doi:10.1093/sleep/33.10.1396 · Cited by 541 · cited 1×
“Acceptance is variable due to side effects and lack of high-quality data on effectiveness for many procedures.(3) An alternative surgical approach to treat OSA is therefore desired.”
BackgroundElectrical stimulation of the lingual musculature in obstructive sleep apnea
Schwartz, A. R., Eisele, D. W., Hari, A., Testerman, R., Erickson, D., & Smith, P. L. (1996) · Journal of Applied Physiology · doi:10.1152/jappl.1996.81.2.643 · Cited by 198 · cited 1×
“Early feasibility studies in humans showed that stimulation could increase maximal inspiratory airflow during sleep by 100% without inducing an arousal.(6) An initial phase I trial of a first-generation device in 8 patients showed a significant decrease in apnea hypopnea index (AHI); however, the device was prone to m…”
Background
Cited by
International Consensus Statement on Obstructive Sleep Apnea
Chang, J. L., Goldberg, A. N., Alt, J. A., Mohammed, A., Ashbrook, L., Auckley, D., Ayappa, I., Bakhtiar, H., Barrera, J. E., Bartley, B. L., et al. (2023) · International Forum of Allergy & Rhinology · doi:10.1002/alr.23079 · Cited by 350
Self-citationUpper Airway Stimulation for Obstructive Sleep Apnea: 5‐Year Outcomes
Woodson, B. T., Strohl, K. P., Soose, R. J., Gillespie, M. B., Maurer, J. T., de Vries, N., Padhya, T. A., Badr, M. S., Lin, H., Vanderveken, O. M., et al. (2018) · Otolaryngology–Head and Neck Surgery · doi:10.1177/0194599818762383 · Cited by 348
“In the same cohort, a randomized withdrawal of therapy demonstrated a devicerelated therapeutic effect and durability, which returned to successful treatment values upon resumption of therapy.(2) Follow-up at 24, 36, and 48 months postimplantation continued to show successful clinical outcomes, low morbidity, and a fa…”
BackgroundSelf-citationThree‐Year Outcomes of Cranial Nerve Stimulation for Obstructive Sleep Apnea: The STAR Trial
Woodson, B. T., Soose, R. J., Gillespie, M. B., Strohl, K. P., Maurer, J. T., de Vries, N., Steward, D. L., Baskin, J. Z., Badr, M. S., Lin, H., et al. (2016) · Otolaryngology–Head and Neck Surgery · doi:10.1177/0194599815616618 · Cited by 268
Self-citationPost-approval upper airway stimulation predictors of treatment effectiveness in the ADHERE registry
Heiser, C., Steffen, A., Boon, M., Hofauer, B., Doghramji, K., Maurer, J. T., Sommer, J. U., Soose, R., Strollo, P. J., Schwab, R., et al. (2019) · European Respiratory Journal · doi:10.1183/13993003.01405-2018 · Cited by 158
Self-citationStimulation Therapy for Apnea Reduction (STAR) Trial Group, Strollo, P. J., Gillespie, M. B., Soose, R. J., Maurer, J. T., de Vries, N., Cornelius, J., Hanson, R. D., Padhya, T. A., Steward, D. L., et al. (2015) · Sleep · doi:10.5665/sleep.5054 · Cited by 149
Self-citationSelective upper airway stimulation for obstructive sleep apnea: a single center clinical experience
Heiser, C., Knopf, A., Bas, M., Gahleitner, C., & Hofauer, B. (2017) · European Archives of Oto-Rhino-Laryngology · doi:10.1007/s00405-016-4297-6 · Cited by 93
“were able to demonstrate the beneficial effect of UAS using a randomized controlled withdrawal study which included the first 46 patients who were successfully treated with UAS during the STAR trial [26].”
MethodHeiser, C., Maurer, J. T., Hofauer, B., Sommer, J. U., Seitz, A., & Steffen, A. (2017) · Otolaryngology–Head and Neck Surgery · doi:10.1177/0194599816683378 · Cited by 91
“Randomized withdrawal of therapy for 1 week at 13 months resulted in return of AHI, ODI, ESS, and FOSQ to baseline levels, and reactivation reestablished therapeutic efficacy as measured at 18 months.(4) More recently, long-term follow-up of the study cohort reported sustained treatment effects and therapy adherence a…”
MethodSelf-citationUpper Airway Stimulation for OSA: Early Adherence and Outcome Results of One Center
Kent, D. T., Lee, J. J., Strollo, P. J., & Soose, R. J. (2016) · Otolaryngology–Head and Neck Surgery · doi:10.1177/0194599816636619 · Cited by 66
Self-citationLiu, S. Y., Huon, L., Lo, M., Chang, Y., Capasso, R., Chen, Y., Shih, T. T., & Wang, P. (2016) · Clinical Otolaryngology · doi:10.1111/coa.12598 · Cited by 46
Upper Airway Stimulation vs Positive Airway Pressure Impact on BP and Sleepiness Symptoms in OSA
Walia, H. K., Thompson, N. R., Strohl, K. P., Faulx, M. D., Waters, T., Kominsky, A., Foldvary-Schaefer, N., & Mehra, R. (2020) · Chest · doi:10.1016/j.chest.2019.06.020 · Cited by 34
Self-citation
Metadata
- Authors
- Woodson, B. T., Gillespie, M. B., Soose, R. J., Maurer, J. T., de Vries, N., Steward, D. L., Baskin, J. Z., Padhya, T. A., Lin, H., Mickelson, S., Badr, S. M., Strohl, K. P., Strollo, P. J., & STAR Trial Investigators
- Venue
- Otolaryngology–Head and Neck Surgery
- Publisher
- Wiley
- Published
- 2014-09-09
- Volume
- 151
- Issue
- 5
- Pages
- 880-887
- ISSN
- 0161-6439 (ISSN-L)
- 0194-5998
- 1097-6817
- OpenAlex
- W2111651939
- Cited by
- 134
- References
- 3
- FWCI
- 8.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.