CoChat

Upper Airway Stimulation for Obstructive Sleep Apnea: Results from the ADHERE Registry

Boon, Maurits, Huntley, Colin, Steffen, Armin, Maurer, Joachim T., Sommer, J. Ulrich, Schwab, Richard, Thaler, Erica, Soose, Ryan, Chou, Courtney, Strollo, Patrick, Kezirian, Eric J., Chia, Stanley, Withrow, Kirk, Weidenbecher, Mark, Strohl, Kingman, Doghramji, Karl, Hofauer, Benedikt, Heiser, Clemens, ADHERE Registry Investigators · 2018 · Otolaryngology–Head and Neck Surgery
Cited by 94

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

Objective: Upper airway stimulation (UAS) is an alternative treatment option for patients unable to tolerate continuous positive airway pressure (CPAP) for the treatment of obstructive sleep apnea (OSA). Studies support the safety and efficacy of this therapy. The aim of this registry is to collect retrospective and prospective objective and subjective outcome measures across multiple institutions in the United States and Germany. To date, it represents the largest cohort of patients studied with this therapy. Study Design: Retrospective and prospective registry study. Setting: Ten tertiary care hospitals in the United States and Germany. Subjects and Methods: Patients were included who had moderate to severe OSA, were intolerant to CPAP, and were undergoing UAS implantation. Baseline demographic and sleep study data were collected. Objective and subjective treatment outcomes, adverse events, and patient and physician satisfaction were reviewed. Results: The registry enrolled 301 patients between October 2016 and September 2017. Mean ± SD AHI decreased from 35.6 ± 15.3 to 10.2 ± 12.9 events per hour (P <. 0001), and Epworth Sleepiness Scale scores decreased from 11.9 ± 5.5 to 7.5 ± 4.7 (P <. 0001) from baseline to the posttitration visit. Patients utilized therapy for 6.5 hours per night. There were low rates of procedure‐ and device‐related complications. Clinical global impression scores demonstrated that the majority of physicians (94%) saw improvement in their patients’ symptoms with therapy. The majority of patients (90%) were more satisfied with UAS than CPAP. Conclusions: Across a multi‐institutional registry, UAS therapy demonstrates significant improvement in subjective and objective OSA outcomes, good therapy adherence, and high patient satisfaction.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/0194599818764896

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

See all 94

Metadata

Authors
Boon, M., Huntley, C., Steffen, A., Maurer, J. T., Sommer, J. U., Schwab, R., Thaler, E., Soose, R., Chou, C., Strollo, P., Kezirian, E. J., Chia, S., Withrow, K., Weidenbecher, M., Strohl, K., Doghramji, K., Hofauer, B., Heiser, C., & ADHERE Registry Investigators
Venue
Otolaryngology–Head and Neck Surgery
Publisher
Wiley
Published
2018-03-20
Volume
159
Issue
2
Pages
379-385
ISSN
  • 0161-6439 (ISSN-L)
  • 0194-5998
  • 1097-6817
OpenAlex
W2793283088
Cited by
94
References
10
FWCI
8.02
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Upper Airway Stimulation for Obstructive Sleep Apnea: Results from the ADHERE Registry. https://app.cochat.ai/papers/10.1177/0194599818764896
The paper
Boon, M., Huntley, C., Steffen, A., Maurer, J. T., Sommer, J. U., Schwab, R., Thaler, E., Soose, R., Chou, C., Strollo, P., Kezirian, E. J., Chia, S., Withrow, K., Weidenbecher, M., Strohl, K., Doghramji, K., Hofauer, B., Heiser, C., & ADHERE Registry Investigators. (2018). Upper Airway Stimulation for Obstructive Sleep Apnea: Results from the ADHERE Registry. Otolaryngology–Head and Neck Surgery. https://doi.org/10.1177/0194599818764896

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.