CoChat

Heparin-coated cardiopulmonary bypass circuits: current status

Hsu, Li-Chien · 2001 · Perfusion
Cited by 77

The DOI matches its Crossref record.

Abstract

Heparin-coated circuits have been subjected to vigorous testing, both experimentally and clinically, for the past decade. When the functions of heparin are preserved on the surface, the heparinized surface plays multiple roles in attenuating the systemic inflammatory response. These include the ability to attenuate contact activation, coagulation activation, complement activation and, directly or indirectly, platelet and leukocyte activation. The heparinized surface also renders the cardiopulmonary bypass (CPB) circuits hydrophilic and protein resistant and augments lipoprotein binding. The multifunctional nature of the heparinized surface contributes to the overall biocompatibility of the surface. Clinically, heparin-coated circuits become most effective in reducing systemic inflammatory response and in improving morbidity, mortality, and other patient outcome related parameters when material-independent blood activation is controlled or minimized through a global biocompatibility strategy. Techniques involved in the global biocompatibility strategy are readily available and are being effectively and safely practiced at several centers. With the global biocompatibility strategy, outstanding and reproducible results have been routinely achieved with conventional CPB techniques. Alternative revascularization procedures should equal or surpass conventional CPB, using best clinically proven strategies with respect to patient outcome and long-term graft patency.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/026765910101600512

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 77

Metadata

Authors
Hsu, L.-C.
Venue
Perfusion
Published
2001-09
Volume
16
Issue
5
Pages
417-428
ISSN
  • 0267-6591 (ISSN-L)
  • 1477-111X
OpenAlex
W2087101432
Cited by
77
References
0
FWCI
4.35
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Heparin-coated cardiopulmonary bypass circuits: current status. https://app.cochat.ai/papers/10.1177/026765910101600512
The paper
Hsu, L.-C. (2001). Heparin-coated cardiopulmonary bypass circuits: current status. Perfusion. https://doi.org/10.1177/026765910101600512

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.