Muscle strength testing with one repetition maximum in the arm/shoulder for people aged 75 + - test-retest reliability
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Objective: To investigate the reliability of a muscle strength test of the arm/shoulder in elderly people, aged 75 and older, and to compare subjects with and without previous muscle strength training experience. Design: Reliability study - test-retest. Setting: Research centre for the elderly. Main measures: One repetition maximum (1 RM) was measured using an arm/shoulder strength-training device (Pull Down, Norway). Two measurements were conducted, approximately one week apart. Results: Forty people were included in the study and 34 completed both sessions. Eleven participants had previous muscle strength training experience on the indicated device. There was a high correlation between the test sessions, r = 0.97 for both groups. The analysis of 95% limits of agreement for the mean difference was -4.3/+6.9 kg for the group without and -3.0/+6.4 kg for the group with previous experience, respectively. Conclusion: One repetition maximum evaluated by the Pull Down device seems to be a reliable and safe method for dosing and evaluating a muscle strength training programme for elderly people. The observed variation of approximately -4/+7 kg cannot be interpreted as an effect of muscle training, but is more likely an effect of learning, fluctuations in daily condition and/or motivation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Six-item screener to identify cognitive impairment among potential subjects for clinical research
Callahan, C. M., Unverzagt, F. W., Hui, S. L., Perkins, A. J., & Hendrie, H. C. (2002) · Medical Care · doi:10.1097/00005650-200209000-00007 · Cited by 1,499
Assessing intrarater, interrater, and test-retest reliability of continuous measurements
Rousson, V., Gasser, T., & Seifert, B. (2002) · Statistics in Medicine · doi:10.1002/sim.1253 · Cited by 415
Cited by
Mijnarends, D. M., Meijers, J. M. M., Halfens, R. J. G., ter Borg, S., Luiking, Y. C., Verlaan, S., Schoberer, D., Cruz Jentoft, A. J., van Loon, L. J. C., & Schols, J. M. G. A. (2013) · Journal of the American Medical Directors Association · doi:10.1016/j.jamda.2012.10.009 · Cited by 475
Test–Retest Reliability of the One-Repetition Maximum (1RM) Strength Assessment: a Systematic Review
Grgic, J., Lazinica, B., Schoenfeld, B. J., & Pedisic, Z. (2020) · Sports Medicine - Open · doi:10.1186/s40798-020-00260-z · Cited by 394
Vanhees, L., Geladas, N., Hansen, D., Kouidi, E., Niebauer, J., Reiner, Ž., Cornelissen, V, Adamopoulos, S., Prescott, E., & Börjesson, M. (2012) · European Journal of Preventive Cardiology · doi:10.1177/1741826711430926 · Cited by 304
Rydwik, E., Lammes, E., Frändin, K., & Akner, G. (2008) · Aging Clinical and Experimental Research · doi:10.1007/bf03324763 · Cited by 96
“A recent reliability study has shown that there is a variability of -4/+7 kg in the pull-down device, which cannot be explained as an effect of strength training, but rather by fluctuating daily condition and/or motivation (16).”
BackgroundMethodSelf-citationZibellini, J., Seimon, R. V., Lee, C. M. Y., Gibson, A. A., Hsu, M. S. H., & Sainsbury, A. (2016) · Obesity Reviews · doi:10.1111/obr.12422 · Cited by 54
Metadata
- Authors
- Rydwik, E., Karlsson, C., Frändin, K., & Akner, G.
- Venue
- Clinical Rehabilitation
- Publisher
- SAGE Publications
- Published
- 2007-03
- Volume
- 21
- Issue
- 3
- Pages
- 258-265
- ISSN
- 0269-2155 (ISSN-L)
- 1477-0873
- OpenAlex
- W2171508020
- Cited by
- 53
- References
- 3
- FWCI
- 2.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.