A Cost-effectiveness Analysis of Alternative At-Home or In-Laboratory Technologies for the Diagnosis of Obstructive Sleep Apnea Syndrome
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Obstructive sleep apnea syndrome (OSAS) is a common disorder that affects 2% to 9% of the population. Health care policy makers have noted increased referrals for sleep studies. OBJECTIVE: In this article, the authors conduct a cost-effectiveness analysis to determine the optimal technology for the diagnosis of OSAS using polysomnography (PSG) or partial sleep monitoring (PSM). DESIGN: The target population was a hypothetical cohort of patients suspected of having OSAS. A 2-level decision tree wasformulated that reflects all possible steps of OSAS diagnosis and therapy. The method represents a comprehensive strategy to determine which of the 2 systems-PSG or PSM-has cost advantages. The financial and operational aspects of OSAS diagnosis and therapy were analyzed. A sensitivity analysis was performed over all uncertain parameters (i.e., diagnostic agreement, data loss, and referral to therapy). RESULTS: Unattended at-home sleep monitoring was the most expensive method. The combination of 1:2 PSG and attended PSM strategy was the optimal strategy with respect tofinancing and operations. Compared to the PSG-only strategy, this combination may lead to a 10% reduction of the annual expenditure. CONCLUSION: This study provides proof of concept (under a wide range of sensitivity assumptions) that the cost of sleep study techniques can be modeled. It rejects the assumption that athome portable sleep monitoring is cost advantageous. The combination of PSG and attended PSM OSAS is the most cost-effective approach to sleep evaluation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chervin, R. D., Murman, D. L., Malow, B. A., & Totten, V. (1999) · Annals of Internal Medicine · doi:10.7326/0003-4819-130-6-199903160-00006 · Cited by 138 · cited 3×
“A recent study by Chervin et al.29 demonstrated an association between OSAS and quality-adjusted life years using the decision tree strategy.”
BackgroundMethod
Cited by
Malhotra, A., & White, D. P. (2002) · The Lancet · doi:10.1016/s0140-6736(02)09464-3 · Cited by 1,190
Impact of sleep apnea on economics
Leger, D., Bayon, V., Laaban, J. P., & Philip, P. (2012) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2011.10.001 · Cited by 201
Masa, J. F., Corral, J., Pereira, R., Duran-Cantolla, J., Cabello, M., Hernandez-Blasco, L., Monasterio, C., Alonso, A., Chiner, E., Rubio, M., et al. (2011) · Thorax · doi:10.1136/thx.2010.152272 · Cited by 161
“favourable to HRP, although other cost studies based on simulated models of hypothetical patient cohorts showed unfavourable cost effectiveness.”
BackgroundGurubhagavatula, I., Nkwuo, J. E., Maislin, G., & Pack, A. I. (2008) · Accident Analysis & Prevention · doi:10.1016/j.aap.2007.04.011 · Cited by 51
Effectiveness of sequential automatic-manual home respiratory polygraphy scoring
Masa, J. F., Corral, J., Pereira, R., Duran-Cantolla, J., Cabello, M., Hernández-Blasco, L., Monasterio, C., Alonso-Fernandez, A., Chiner, E., Vázquez-Polo, F.-J., et al. (2013) · European Respiratory Journal · doi:10.1183/09031936.00186811 · Cited by 44
Metadata
- Authors
- Reuveni, H., Schweitzer, E., & Tarasiuk, A.
- Venue
- Medical Decision Making
- Publisher
- SAGE Publications
- Published
- 2001-12-01
- Volume
- 21
- Issue
- 6
- Pages
- 451-458
- ISSN
- 0272-989X (ISSN-L)
- 0000-0000
- OpenAlex
- W2101679843
- Cited by
- 53
- References
- 1
- FWCI
- 1.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Cost-effectiveness Analysis of Alternative At-Home or In-Laboratory Technologies for the Diagnosis of Obstructive Sleep Apnea Syndrome. https://app.cochat.ai/papers/10.1177/02729890122062802
- The paper
- Reuveni, H., Schweitzer, E., & Tarasiuk, A. (2001). A Cost-effectiveness Analysis of Alternative At-Home or In-Laboratory Technologies for the Diagnosis of Obstructive Sleep Apnea Syndrome. Medical Decision Making. https://doi.org/10.1177/02729890122062802
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.