Estimating Diagnostic Test Accuracy Using a "Fuzzy Gold Standard"
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
This study uses Monte Carlo methods to analyze the consequences of having a criterion standard ("gold standard") that contains some error when analyzing the accuracy of a diagnostic test using ROC curves. Two phenomena emerge: 1) When diagnostic test errors are statistically independent from inaccurate ("fuzzy") gold standard (FGS) errors, estimated test accuracy declines. 2) When the test and the FGS have statistically dependent errors, test accuracy can become overstated. Two methods are proposed to eliminate the first of these errors, exploring the risk of exacerbating the second. Both require a probabilistic (rather than binary) gold-standard statement (e.g., probability that each case is abnormal). The more promising of these, the "two-truth" method, selectively eliminates those cases where the gold standard is most ambiguous (probability near 0.5). When diagnostic test and FGS errors are independent, this approach can eliminate much of the downward bias caused by FGS error, without meaningful risk of overstating test accuracy. When the test and FGS have dependent errors, the resultant upward bias can cause test accuracy to be overstated, in the most extreme cases, even before the offsetting "two-truth" approach is employed. Key words: ROC curves; diagnostic test accuracy; technology assessment. (Med Decis Making 1995;15:44-57)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Estimating the Error Rates of Diagnostic Tests
Hui, S. L., & Walter, S. D. (1980) · Biometrics · doi:10.2307/2530508 · Cited by 780
Cited by
Receiver-operating characteristic analysis for evaluating diagnostic tests and predictive models
Zou, K. H., O’Malley, A. J., & Mauri, L. (2007) · Circulation · doi:10.1161/circulationaha.105.594929 · Cited by 1,473
Nanda, K., McCrory, D. C., Myers, E. R., Bastian, L. A., Hasselblad, V., Hickey, J. D., & Matchar, D. B. (2000) · Annals of Internal Medicine · doi:10.7326/0003-4819-132-10-200005160-00009 · Cited by 1,089
Sources of Variation and Bias in Studies of Diagnostic Accuracy: A Systematic Review
Whiting, P., Rutjes, A. W. S., Reitsma, J. B., Glas, A. S., Bossuyt, P. M. M., & Kleijnen, J. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-140-3-200402030-00010 · Cited by 798
Statistical Evaluation of Prognostic versus Diagnostic Models: Beyond the ROC Curve
Cook, N. R. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.096529 · Cited by 691
Assessing the quality of research.
Glasziou, P., Vandenbroucke, J., & Chalmers, I. (2004) · BMJ · doi:10.1136/bmj.328.7430.39 · Cited by 391
The interpretation of diagnostic tests
Shapiro, D. E. (1999) · Statistical Methods in Medical Research · doi:10.1177/096228029900800203 · Cited by 383
Development and validation of methods for assessing the quality of diagnostic accuracy studies
Whiting, P., Rutjes, A., Dinnes, J., Reitsma, J., Bossuyt, P., & Kleijnen, J. (2004) · Health Technology Assessment · doi:10.3310/hta8250 · Cited by 372
Zangwill, L. M. (2001) · Archives of Ophthalmology · doi:10.1001/archopht.119.7.985 · Cited by 344
A systematic review classifies sources of bias and variation in diagnostic test accuracy studies
Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., & Mallett, S. (2013) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2013.05.014 · Cited by 283
Imperfect Gold Standards for Kidney Injury Biomarker Evaluation
Waikar, S. S., Betensky, R. A., Emerson, S. C., & Bonventre, J. V. (2012) · Journal of the American Society of Nephrology · doi:10.1681/asn.2010111124 · Cited by 279
Exceeding the limits of liver histology markers
Mehta, S. H., Lau, B., Afdhal, N. H., & Thomas, D. L. (2009) · Journal of Hepatology · doi:10.1016/j.jhep.2008.07.039 · Cited by 273
Reliability and validity of two self-report measures of impairment and disability for MS
Schwartz, C. E., Vollmer, T., Lee, H., & the North American Research Consortium on Multiple Sclerosis Outcomes Study Group (1999) · Neurology · doi:10.1212/wnl.52.1.63 · Cited by 236
Metadata
- Authors
- Phelps, C. E., & Hutson, A.
- Venue
- Medical Decision Making
- Publisher
- SAGE Publications
- Published
- 1995-02
- Volume
- 15
- Issue
- 1
- Pages
- 44-57
- ISSN
- 0272-989X (ISSN-L)
- 1552-681X
- OpenAlex
- W1984017375
- Cited by
- 73
- References
- 1
- FWCI
- 4.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.