The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Artificial Muscles: Actuators for Biorobotic Systems
Abstract
Biorobotic research seeks to develop new robotic technologies modeled after the performance of human and animal neuromuscular systems. The development of one component of a biorobotic system, an artificial muscle and tendon, is reported here. The device is based on known static and dynamic properties of biological muscle and tendon that were extracted from the literature and used to mathematically describe their force, length, and velocity relationships. A flexible pneumatic actuator is proposed as the contractile element of the artificial muscle and experimental results are presented that show the force-length properties of the actuator are muscle-like, but the force-velocity properties are not. The addition of a hydraulic damper is put forward to improve the actuator's velocity-dependent properties. Further, an artificial tendon is set forth whose function is to serve as connective tissue between the artificial muscle and a skeletal structure. A complete model of the artificial muscle-tendon system is then presented which predicts the expected force-length-velocity performance of the artificial system. Experimental results of the constructed device indicate muscle-like performance in general: higher activation pressures yielded higher output forces, faster concentric contractions resulted in lower force outputs, faster eccentric contractions produced higher force outputs, and output forces were higher at longer muscle lengths than shorter lengths.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The variation in isometric tension with sarcomere length in vertebrate muscle fibres
Gordon, A. M., Huxley, A. F., & Julian, F. J. (1966) · The Journal of Physiology · doi:10.1113/jphysiol.1966.sp007909 · Cited by 3,152
Measurement and modeling of McKibben pneumatic artificial muscles
Chou, C.-P., & Hannaford, B. (1996) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.481753 · Cited by 1,589 · cited 2×
“…the actuator; these models fall into several categories: (a) empirical models (Gavrilovic and Maric 1969; Medrano-Cerda, Bowler and Caldwell 1995; Chou and Hannaford 1996), (b) models based on geometry (Schulte 1961; Inoue 1987; Tondu, Boitier and Lopez 1994; Cai and Yamaura 1996; Chou and…”
BackgroundMethodSelf-citationThe relation between force and velocity in human muscle
Wilkie, D. R. (1949) · The Journal of Physiology · doi:10.1113/jphysiol.1949.sp004437 · Cited by 632
Winters, J. M., & Stark, L. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325498 · Cited by 526 · cited 1×
“Asymptotic values for these models are typically assumed to be 1.3 FL,o (e.g., Hatze 1981; Winters and Stark 1985); however, values ranging from as low as 1.2 FL,o (Hof and Van den Berg 1981) to as high as 1.8 FL,o (Lehman 1990) have been used.”
BackgroundInfluential
Cited by
Modelling of the McKibben artificial muscle: A review
Tondu, B. (2012) · Journal of Intelligent Material Systems and Structures · doi:10.1177/1045389x11435435 · Cited by 490
An Ankle-Foot Orthosis Powered by Artificial Pneumatic Muscles
Ferris, D. P., Czerniecki, J. M., & Hannaford, B. (2005) · Journal of Applied Biomechanics · doi:10.1123/jab.21.2.189 · Cited by 376
Self-citationAn improved powered ankle–foot orthosis using proportional myoelectric control
Ferris, D. P., Gordon, K. E., Sawicki, G. S., & Peethambaran, A. (2006) · Gait & Posture · doi:10.1016/j.gaitpost.2005.05.004 · Cited by 342
A Seven-degrees-of-freedom Robot-arm Driven by Pneumatic Artificial Muscles for Humanoid Robots
Tondu, B., Ippolito, S., Guiochet, J., & Daidie, A. (2005) · The International Journal of Robotics Research · doi:10.1177/0278364905052437 · Cited by 304
Au, S., & Herr, H. (2008) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2008.927697 · Cited by 280
Metadata
- Authors
- Klute, G. K., Czerniecki, J. M., & Hannaford, B.
- Venue
- The International Journal of Robotics Research
- Publisher
- SAGE Publications
- Published
- 2002-04
- Volume
- 21
- Issue
- 4
- Pages
- 295-309
- ISSN
- 0278-3649 (ISSN-L)
- 1741-3176
- OpenAlex
- W2064657462
- Cited by
- 208
- References
- 4
- FWCI
- 3.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.