The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
A Seven-degrees-of-freedom Robot-arm Driven by Pneumatic Artificial Muscles for Humanoid Robots
Open accessAbstract
Braided pneumatic artificial muscles, and in particular the better known type with a double helical braid usually called the McKibben muscle, seem to be at present the best means for motorizing robot-arms with artificial muscles. Their ability to develop high maximum force associated with lightness and a compact cylindrical shape, as well as their analogical behavior with natural skeletal muscle were very well emphasized in the 1980s by the development of the Bridgestone “soft robot” actuated by “rubbertuators”. Recent publications have presented ways for modeling McKibben artificial muscle as well as controlling its highly non-linear dynamic behavior. However, fewer studies have concentrated on analyzing the integration of artificial muscles with robot-arm architectures since the first Bridgestone prototypes were designed. In this paper we present the design of a 7R anthropomorphic robot-arm entirely actuated by antagonistic McKibben artificial muscle pairs. The validation of the robot-arm architecture was performed in a teleoperation mode.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measurement and modeling of McKibben pneumatic artificial muscles
Chou, C.-P., & Hannaford, B. (1996) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.481753 · Cited by 1,589
Development and Control of a ‘Soft-Actuated’ Exoskeleton for Use in Physiotherapy and Training
Tsagarakis, N. G., & Caldwell, D. G. (2003) · Autonomous Robots · doi:10.1023/a:1024484615192 · Cited by 335
Cited by
Modelling of the McKibben artificial muscle: A review
Tondu, B. (2012) · Journal of Intelligent Material Systems and Structures · doi:10.1177/1045389x11435435 · Cited by 490
Self-citationA Review of Algorithms for Compliant Control of Stiff and Fixed-Compliance Robots
Calanca, A., Muradore, R., & Fiorini, P. (2016) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2015.2465849 · Cited by 320
Cheng, N. G., Lobovsky, M. B., Keating, S. J., Setapen, A. M., Gero, K. I., Hosoi, A. E., & Iagnemma, K. D. (2012) · 2012 IEEE International Conference on Robotics and Automation · doi:10.1109/icra.2012.6225373 · Cited by 314
Park, J. H., Kim, K., Gong, Y. J., Yang, S. Y., Hwang, S. T., Jung, H. S., Moon, H., Koo, J. C., Rodrigue, H., & Choi, H. R. (2024) · Mechatronics · doi:10.1016/j.mechatronics.2023.103099 · Cited by 15
Metadata
- Authors
- Tondu, B., Ippolito, S., Guiochet, J., & Daidie, A.
- Venue
- The International Journal of Robotics Research
- Publisher
- SAGE Publications
- Published
- 2005-04
- Volume
- 24
- Issue
- 4
- Pages
- 257-274
- ISSN
- 0278-3649 (ISSN-L)
- 1741-3176
- OpenAlex
- W2053036469
- Cited by
- 304
- References
- 2
- FWCI
- 4.82
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Seven-degrees-of-freedom Robot-arm Driven by Pneumatic Artificial Muscles for Humanoid Robots. https://app.cochat.ai/papers/10.1177/0278364905052437
- The paper
- Tondu, B., Ippolito, S., Guiochet, J., & Daidie, A. (2005). A Seven-degrees-of-freedom Robot-arm Driven by Pneumatic Artificial Muscles for Humanoid Robots. The International Journal of Robotics Research. https://doi.org/10.1177/0278364905052437
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.