The DOI matches its OpenAlex record; 1 of the 1 references it cites were found in a registry or an index.
Quantitative Safety Guarantees for Physical Human-Robot Interaction
Abstract
If robots are to be introduced into the human world as assistants to aid a person in the completion of a manual task two key problems of today's robots must be solved. The human-robot interface must be intuitive to use and the safety of the user with respect to injuries inflicted by collisions with the robot must be guaranteed. In this paper we describe the formulation and implementation of a control strategy for robot manipulators which provides quantitative safety guarantees for the user of assistant-type robots. We propose a control scheme for robot manipulators that restricts the torque commands of a position control algorithm to values that comply to preset safety restrictions. These safety restrictions limit the potential impact force of the robot in the case of a collision with a person. Such accidental collisions may occur with any part of the robot and therefore the impact force not only of the robot's hand but of all surfaces is controlled by the scheme. The integration of a visual control interface and the safely con trolled robot allows the safe and intuitive interaction between a per son and the robot. As an example application, the system is pro grammed to retrieve eye-gaze-selected objects from a table and to hand them over to the user on demand.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Impedance Control: An Approach to Manipulation: Part I—Theory
Hogan, N. (1985) · Journal of Dynamic Systems, Measurement, and Control · doi:10.1115/1.3140702 · Cited by 3,673
Cited by
Bartneck, C., Kulić, D., Croft, E., & Zoghbi, S. (2009) · International Journal of Social Robotics · doi:10.1007/s12369-008-0001-3 · Cited by 3,193
An atlas of physical human–robot interaction
De Santis, A., Siciliano, B., De Luca, A., & Bicchi, A. (2008) · Mechanism and Machine Theory · doi:10.1016/j.mechmachtheory.2007.03.003 · Cited by 826
Collision Detection and Safe Reaction with the DLR-III Lightweight Manipulator Arm
De Luca, A., Albu-Schaffer, A., Haddadin, S., & Hirzinger, G. (2006) · 2006 IEEE/RSJ International Conference on Intelligent Robots and Systems · doi:10.1109/iros.2006.282053 · Cited by 779
Symbiotic human-robot collaborative assembly
Wang, L., Gao, R., Váncza, J., Krüger, J., Wang, X. V., Makris, S., & Chryssolouris, G. (2019) · CIRP Annals · doi:10.1016/j.cirp.2019.05.002 · Cited by 565
Collision Detection and Reaction: A Contribution to Safe Physical Human-Robot Interaction
Haddadin, S., Albu-Schaffer, A., De Luca, A., & Hirzinger, G. (2008) · 2008 IEEE/RSJ International Conference on Intelligent Robots and Systems · doi:10.1109/iros.2008.4650764 · Cited by 562
Metadata
- Authors
- Heinzmann, J., & Zelinsky, A.
- Venue
- The International Journal of Robotics Research
- Publisher
- SAGE Publishing
- Published
- 2003-07-01
- Volume
- 22
- Issue
- 7
- Pages
- 479-504
- ISSN
- 0278-3649 (ISSN-L)
- OpenAlex
- W2015016121
- Cited by
- 234
- References
- 1
- FWCI
- 4.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quantitative Safety Guarantees for Physical Human-Robot Interaction. https://app.cochat.ai/papers/10.1177/027836403128965231
- The paper
- Heinzmann, J., & Zelinsky, A. (2003). Quantitative Safety Guarantees for Physical Human-Robot Interaction. The International Journal of Robotics Research. https://doi.org/10.1177/027836403128965231
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.