The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Modeling and Control of Untethered Biomicrorobots in a Fluidic Environment Using Electromagnetic Fields
Abstract
This paper investigates fundamental design, modeling, and control issues related to untethered biomedical microrobots guided inside the human body through external magnetic fields. Proposed areas of application for these microrobots include sensing, diagnosis, and surgical procedures in intraocular, cardiovascular, and inner-ear environments. A prototype microrobot and steering system are introduced. Fluid drag experiments performed on the prototype robot show that the 950 × 400 μ m elliptical shape has a spherical equivalent diameter of 477 μ m. Drag forces combined with saturation magnetization (5 × 10 5 A/m) of the prototype indicate that the required magnetic field gradients for application inside the vitreous humor and blood vessels are on the order of 0.7T/m.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Handbook of Biomaterial Properties
Black, J. T. (1998) · Springer eBooks · doi:10.1007/978-1-4615-5801-9 · Cited by 734
Electromagnetic Analysis and Design in Magnetic Resonance Imaging
Jin, J. (2018) · Routledge eBooks · doi:10.1201/9780203758731 · Cited by 502
Silbernagl, S., Despopoulos, A., et al. (2008) · Thieme eBooks · doi:10.1055/b-005-148941 · Cited by 281
Amblard, F., Yurke, B., Pargellis, A., & Leibler, S. (1996) · Review of Scientific Instruments · doi:10.1063/1.1146816 · Cited by 191
Rheology of the vitreous body. Part I: Viscoelasticity of human vitreous
Lee, B., Litt, M., & Buchsbaum, G. (1992) · Biorheology · doi:10.3233/bir-1992-295-612 · Cited by 179
Weiss, J. N. (1998) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(98)00086-5 · Cited by 100
Adapting MRI systems to propel and guide microdevices in the human blood circulatory system
Martel, S. M., Mathieu, J., Felfoul, O., Macicior, H., Beaudoin, G., Soulez, G., & Yahia, L. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2004.1403342 · Cited by 47
Chirilă, T. V., & Hong, Y. (1998) · Springer eBooks · doi:10.1007/978-1-4615-5801-9_12 · Cited by 20
Cited by
Microrobots for Minimally Invasive Medicine
Nelson, B. J., Kaliakatsos, I. K., & Abbott, J. J. (2010) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-010510-103409 · Cited by 1,968
Self-citationArtificial bacterial flagella: Fabrication and magnetic control
Zhang, L., Abbott, J. J., Dong, L., Kratochvil, B. E., Bell, D., & Nelson, B. J. (2009) · Applied Physics Letters · doi:10.1063/1.3079655 · Cited by 1,199
Self-citationOctoMag: An Electromagnetic System for 5-DOF Wireless Micromanipulation
Kummer, M. P., Abbott, J. J., Kratochvil, B. E., Borer, R., Sengul, A., & Nelson, B. J. (2010) · IEEE Transactions on Robotics · doi:10.1109/tro.2010.2073030 · Cited by 1,161
Self-citationBiomedical Applications of Untethered Mobile Milli/Microrobots
Sitti, M., Ceylan, H., Hu, W., Giltinan, J., Turan, M., Yim, S., & Diller, E. (2015) · Proceedings of the IEEE · doi:10.1109/jproc.2014.2385105 · Cited by 893
Abbott, J. J., Peyer, K. E., Lagomarsino, M. C., Zhang, L., Dong, L., Kaliakatsos, I. K., & Nelson, B. J. (2009) · The International Journal of Robotics Research · doi:10.1177/0278364909341658 · Cited by 680
Self-citation
Metadata
- Authors
- Yesin, K. B., Vollmers, K., & Nelson, B. J.
- Venue
- The International Journal of Robotics Research
- Publisher
- SAGE Publications
- Published
- 2006-05
- Volume
- 25
- Issue
- 5-6
- Pages
- 527-536
- ISSN
- 0278-3649 (ISSN-L)
- 1741-3176
- OpenAlex
- W2116813238
- Cited by
- 465
- References
- 8
- FWCI
- 20.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.