Automatic transportation of biological cells with a robot-tweezer manipulation system
The DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.
Abstract
The positioning of biological cells has become increasingly important in biomedical research such as drug discovery, cell-to-cell interaction, and tissue engineering. Significant demand for both accuracy and productivity in cell manipulation highlights the need for automated cell transportation with integrated robotics and micro/nano-manipulation technologies. Optical tweezers, which use highly focused low-power laser beams to trap and manipulate particles at the micro/nanoscale, can be treated as special robot ‘end-effectors’ to manipulate biological objects in a noninvasive way. In this paper, we propose to use a robot-tweezer manipulation system for automatic transportation of biological cells. A dynamics equation of the cell in an optical trap is analyzed. Closed-loop controllers are designed for positioning single cells as well as multiple cells. A synchronization control technology is utilized for multicell transportation with maintained cell pattern. Experiments are performed on transporting live cells to demonstrate the effectiveness of the proposed approach.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Observation of a single-beam gradient force optical trap for dielectric particles
Ashkin, A., Dziedzic, J. M., Bjorkholm, J. E., & Chu, S. (1986) · Optics Letters · doi:10.1364/ol.11.000288 · Cited by 7,030 · cited 2×
“, 2004) and dielectrophoresis (Hughes, 2002), hydrodynamic flows (Kessler, 1985), and optical tweezers (Ashkin et al., 1986; Maruo et al., 2003), to name a few.”
BackgroundNeuman, K. C., & Block, S. M. (2004) · Review of Scientific Instruments · doi:10.1063/1.1785844 · Cited by 2,165
El-Ali, J., Sorger, P. K., & Jensen, K. F. (2006) · Nature · doi:10.1038/nature05063 · Cited by 2,102
Nanotubular Highways for Intercellular Organelle Transport
Rustom, A., Saffrich, R., Markovic, I., Walther, P., & Gerdes, H.-H. (2004) · Science · doi:10.1126/science.1093133 · Cited by 2,038 · cited 1×
“Contemporary prokaryotes and eukaryotes have an inherent property of being together via temporary or stable cell–cell channels, such as tunneling nanotubes (TNTs), cytoplasmic bridges, and tight junctions (Rustom et al., 2004; Baluska et al., 2006; Gerdes and Carvalho, 2008).”
BackgroundBiological Applications of Optical Forces
Svoboda, K., & Block, S. M. (1994) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.bb.23.060194.001335 · Cited by 1,792 · cited 8×
“The trapping force applied by a laser beam to the cell is customarily defined as follows (Svoboda and Block, 1994):”
BackgroundMethodInfluentialDynamic holographic optical tweezers
Curtis, J. E., Koss, B. A., & Grier, D. G. (2002) · Optics Communications · doi:10.1016/s0030-4018(02)01524-9 · Cited by 1,531 · cited 2×
“With relay optics, the phasemodified laser beam is transferred to be the input pupil of an inverted objective (Nikon, Plan Apo 60X/1.20 WI), and then focused into holographic optical tweezers (Curtis et al., 2002).”
BackgroundMethodInfluentialMassively parallel manipulation of single cells and microparticles using optical images
Chiou, P. Y., Ohta, A. T., & Wu, M. C. (2005) · Nature · doi:10.1038/nature03831 · Cited by 1,444 · cited 1×
“Other tools such as magnetic tweezers, hydrodynamic flows and electrokinetics have exhibited the advantages of high throughput for the manipulation of cells, but lack the flexibility or spatial resolution necessary for controlling individual cells (Chiou et al., 2005).”
BackgroundMicropipette aspiration of living cells
Hochmuth, R. M. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(99)00175-x · Cited by 1,423 · cited 2×
“To achieve this goal, many efforts have been made towards the development of various micromanipulation tools, such as micropipette aspiration (Hochmuth, 2000), atomic force microscopy (AFM) (Li et al.”
BackgroundSowinski, S., Jolly, C., Berninghausen, O., Purbhoo, M. A., Chauveau, A., Köhler, K., Oddos, S., Eissmann, P., Brodsky, F. M., Hopkins, C., et al. (2008) · Nature Cell Biology · doi:10.1038/ncb1682 · Cited by 754 · cited 2×
“Trapping and manipulation of single/multiple T cells are very useful and have been widely studied (Creely et al., 2005; Harris and McConnell, 2008; Sowinski et al., 2008; McNerney et al., 2010).”
Background2011 IEEE International Conference on Robotics and Automation
(2009) · IEEE Transactions on Haptics · doi:10.1109/toh.2009.52 · Cited by 536
Cited by
Fan, T., Long, P., Liu, W., & Pan, J. (2020) · The International Journal of Robotics Research · doi:10.1177/0278364920916531 · Cited by 332
3D-printed microrobots from design to translation
Dabbagh, S. R., Sarabi, M. R., Birtek, M. T., Seyfi, S., Sitti, M., & Tasoglu, S. (2022) · Nature Communications · doi:10.1038/s41467-022-33409-3 · Cited by 188
Metadata
- Authors
- Hu, S., & Sun, D.
- Venue
- The International Journal of Robotics Research
- Publisher
- SAGE Publications
- Published
- 2011-08-15
- Volume
- 30
- Issue
- 14
- Pages
- 1681-1694
- ISSN
- 0278-3649 (ISSN-L)
- 1741-3176
- OpenAlex
- W2071356645
- Cited by
- 188
- References
- 48
- FWCI
- 12.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.