Cited by 598Robot Manipulation and LearningSoft Robotics and ApplicationsRobotic Mechanisms and Dynamics

A compliant, underactuated hand for robust manipulation

Odhner, Lael U., Jentoft, Leif P., Claffee, Mark R., Corson, Nicholas, Tenzer, Yaroslav, Ma, Raymond R., Buehler, Martin, Kohout, Robert +2 more·2014·The International Journal of Robotics Research

Abstract

This paper introduces the iRobot-Harvard-Yale (iHY) Hand, an underactuated hand driven by five actuators that is capable of performing a wide range of grasping and in-hand repositioning tasks. This hand was designed to address the need for a durable, inexpensive, moderately dexterous hand suitable for use on mobile robots. The primary focus of this paper will be on the novel simplified design of the iHY Hand, which was developed by choosing a set of target tasks around which the hand was optimized. Particular emphasis is placed on the development of underactuated fingers that are capable of both firm power grasps and low-stiffness fingertip grasps using only the compliant mechanics of the fingers. Experimental results demonstrate successful grasping of a wide range of target objects, the stability of fingertip grasping, and the ability to adjust the force exerted on grasped objects using high-impedance actuators and underactuated fingers.

Integrity signals

Registry

Crossref · 10.1177/0278364913514466

Cites

57 of 57 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Robot hands have been designed with just one actuated degree of freedom (one motor) but multiple joints; when the robot contacts an object to be grasped, it conforms to the object's shape.

    “For example, robot hands have been designed with just one actuated degree of freedom (one motor), but multiple joints (Odhner et al., 2014; Deimel and Brock, 2016). When the robot contacts an object to be grasped, it conforms to the object’s shape.”

    From Lessons for Robotics From the Control Architecture of the Octopus (2022) · cites this paper as Odhner et al., 2014

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Odhner, L. U., Jentoft, L. P., Claffee, M. R., Corson, N., Tenzer, Y., Ma, R. R., Buehler, M., Kohout, R., Howe, R. D., & Dollar, A. M.
Affiliations
  • Yale University (US)
  • Harvard University (US)
  • iRobot (United States) (US)
Venue
The International Journal of Robotics Research
Published
2014-02-17
Volume
33
Issue
5
Pages
736-752
ISSN
  • 0278-3649 (ISSN-L)
  • 1741-3176
OpenAlex
W2048058874
Cited by
598
References
57
Citations by year
2026: 28 · 2025: 38 · 2024: 43 · 2023: 44 · 2022: 52 · 2021: 59 · 2020: 49 · 2019: 45 · 2018: 70 · 2017: 60 · 2016: 52 · 2015: 36 · 2014: 20 · 2013: 2
FWCI
62.35
Type
journal article
Language
en
Open access
closed
Locations
The International Journal of Robotics Research (publishedVersion)
Funders
  • Yale University
  • Harvard University
  • Defense Advanced Research Projects Agency
Topics
  • Physical Sciences › Engineering › Control and Systems Engineering › Robot Manipulation and Learning
  • Physical Sciences › Engineering › Biomedical Engineering › Soft Robotics and Applications
  • Physical Sciences › Engineering › Control and Systems Engineering › Robotic Mechanisms and Dynamics
Keywords
underactuated hand, compliant fingers, grasping, power grip, dexterous manipulation

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review