Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 170

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Diagnostic role of Gallium-68 DOTATOC and Gallium-68 DOTATATE PET in patients with neuroendocrine tumors: a meta-analysis

Yang, Jigang, Kan, Ying, Ge, Benjamin H, Yuan, Leilei, Li, Chunlin, Zhao, Wenrui · 2014 · Acta Radiologica

Abstract

Background: Gallium-68 somatostatin receptor positron emission tomography (PET) has been used in the diagnosis of neuroendocrine tumors (NETs). The compounds often used in molecular imaging of NETs with PET are 68Ga-DOTATOC, 68Ga-DOTATATE, and 68Ga-DOTANOC. There is varying affinity to different somatostatin receptors. Purpose: To systematically review and perform a meta-analysis of published data regarding the diagnostic role of 68Ga-DOTATOC and 68Ga-DOTATATE PET in the diagnosis of NETs. Material and Methods: A comprehensive literature search of studies published through 30 April 2013 regarding 68Ga-DOTATOC and 68Ga-DOTATATE PET in the diagnosis of NETs was performed using the PubMed/MEDLINE, Embase, and Scopus databases. Pooled sensitivity and specificity of 68Ga-DOTATOC and 68Ga-DOTATATE PET in the diagnosis of NETs were calculated. The area under the receiver-operating characteristic (ROC) curve was calculated to measure the accuracy of 68Ga-DOTATOC and 68Ga-DOTATATE PET in the diagnosis of NETs. Results: Ten studies comprising 416 patients with NETs were included in this meta-analysis. The pooled sensitivity of 68Ga-DOTATOC and 68Ga-DOTATATE PET in the diagnosis of NETs calculated on a per-patient-based analysis was 93% (95% confidence interval [CI] 89–96%) and 96% (95% CI 91–99%). The pooled specificity of 68Ga-DOTATOC and 68Ga-DOTATATE PET in diagnosing NETs was 85% (95% CI 74–93%) and 100% (95% CI 82–100%). The area under the ROC curve of 68Ga-DOTATOC and 68Ga-DOTATATE PET was 0.96 and 0.98, respectively, on a per-patient-based analysis. Conclusion: The molecular imaging agents 68Ga-DOTATOC and 68Ga-DOTATATE demonstrated high sensitivity and specificity in the diagnosis of NETs on PET scan. Although both are accurate tools in the diagnosis of NETs, 68Ga-DOTATATE PET may be more sensitive and specific than 68Ga-DOTATOC PET scan.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/0284185113496679

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 170

Metadata

Authors
Yang, J., Kan, Y., Ge, B. H., Yuan, L., Li, C., & Zhao, W.
Venue
Acta Radiologica
Published
2014-05
Volume
55
Issue
4
Pages
389-398
ISSN
  • 0284-1851 (ISSN-L)
  • 1600-0455
OpenAlex
W2324995181
Cited by
170
References
1
FWCI
2.08
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Diagnostic role of Gallium-68 DOTATOC and Gallium-68 DOTATATE PET in patients with neuroendocrine tumors: a meta-analysis. https://app.cochat.ai/papers/10.1177/0284185113496679
The paper
Yang, J., Kan, Y., Ge, B. H., Yuan, L., Li, C., & Zhao, W. (2014). Diagnostic role of Gallium-68 DOTATOC and Gallium-68 DOTATATE PET in patients with neuroendocrine tumors: a meta-analysis. Acta Radiologica. https://doi.org/10.1177/0284185113496679

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.