Diagnostic role of Gallium-68 DOTATOC and Gallium-68 DOTATATE PET in patients with neuroendocrine tumors: a meta-analysis
The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
Background: Gallium-68 somatostatin receptor positron emission tomography (PET) has been used in the diagnosis of neuroendocrine tumors (NETs). The compounds often used in molecular imaging of NETs with PET are 68Ga-DOTATOC, 68Ga-DOTATATE, and 68Ga-DOTANOC. There is varying affinity to different somatostatin receptors. Purpose: To systematically review and perform a meta-analysis of published data regarding the diagnostic role of 68Ga-DOTATOC and 68Ga-DOTATATE PET in the diagnosis of NETs. Material and Methods: A comprehensive literature search of studies published through 30 April 2013 regarding 68Ga-DOTATOC and 68Ga-DOTATATE PET in the diagnosis of NETs was performed using the PubMed/MEDLINE, Embase, and Scopus databases. Pooled sensitivity and specificity of 68Ga-DOTATOC and 68Ga-DOTATATE PET in the diagnosis of NETs were calculated. The area under the receiver-operating characteristic (ROC) curve was calculated to measure the accuracy of 68Ga-DOTATOC and 68Ga-DOTATATE PET in the diagnosis of NETs. Results: Ten studies comprising 416 patients with NETs were included in this meta-analysis. The pooled sensitivity of 68Ga-DOTATOC and 68Ga-DOTATATE PET in the diagnosis of NETs calculated on a per-patient-based analysis was 93% (95% confidence interval [CI] 89–96%) and 96% (95% CI 91–99%). The pooled specificity of 68Ga-DOTATOC and 68Ga-DOTATATE PET in diagnosing NETs was 85% (95% CI 74–93%) and 100% (95% CI 82–100%). The area under the ROC curve of 68Ga-DOTATOC and 68Ga-DOTATATE PET was 0.96 and 0.98, respectively, on a per-patient-based analysis. Conclusion: The molecular imaging agents 68Ga-DOTATOC and 68Ga-DOTATATE demonstrated high sensitivity and specificity in the diagnosis of NETs on PET scan. Although both are accurate tools in the diagnosis of NETs, 68Ga-DOTATATE PET may be more sensitive and specific than 68Ga-DOTATOC PET scan.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measuring inconsistency in meta-analyses
Higgins, J. P. T., Thompson, S. G., Deeks, J. J., & Altman, D. G. (2003) · BMJ · doi:10.1136/bmj.327.7414.557 · Cited by 63,139 · cited 1×
“An I-square statistic was also performed to test for heterogeneity between studies (15).”
MethodMeta-DiSc: a software for meta-analysis of test accuracy data
Zamora, J., Abraira, V., Muriel, A., Khan, K., & Coomarasamy, A. (2006) · BMC Medical Research Methodology · doi:10.1186/1471-2288-6-31 · Cited by 1,883
Krenning, E. P., Kwekkeboom, D. J., Bakker, W. H., Breeman, W. A. P., Kooij, P. P. M., Oei, H. Y., van Hagen, M., Postema, P. T. E., de Jong, M., Reubi, J. C., et al. (1993) · European Journal of Nuclear Medicine · doi:10.1007/bf00181765 · Cited by 1,564 · cited 1×
“Somatostatin receptor scans (SRS), with 111In, 123I, 99mTc label, are utilized in the diagnosis and staging of NETs (5).”
MethodReubi, J. C., Schär, J.-C., Waser, B., Wenger, S., Heppeler, A., Schmitt, J. S., & Mäcke, H. R. (2000) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s002590050034 · Cited by 1,127 · cited 1×
“reported that the affinity of 68GaDOTATATE in binding SST2 to be approximately 10-fold higher than that of 68Ga-DOTATOC (36).”
BackgroundGabriel, M., Decristoforo, C., Kendler, D., Dobrozemsky, G., Heute, D., Uprimny, C., Kovacs, P., Von Guggenberg, E., Bale, R., & Virgolini, I. J. (2007) · Journal of Nuclear Medicine · doi:10.2967/jnumed.106.035667 · Cited by 1,010
Reubi, J., Waser, B., Schaer, J.-C., & Laissue, J. A. (2001) · European Journal of Nuclear Medicine · doi:10.1007/s002590100541 · Cited by 657 · cited 1×
“The expression of the various SST subtypes and their density on the tumor cell surface differs among the various tumors with a predominance of SST2 in NETs (29).”
BackgroundLOCALISATION OF ENDOCRINE-RELATED TUMOURS WITH RADIOIODINATED ANALOGUE OF SOMATOSTATIN
Krenning, E. P., Breeman, W. A. P., Kooij, P. P. M., Lameris, J. S., Bakker, W. H., Koper, J. W., Ausema, L., Reubi, J. C., & Lamberts, S. W. J. (1989) · The Lancet · doi:10.1016/s0140-6736(89)91258-0 · Cited by 625 · cited 1×
“reported the scintigraphy of NETs expressing somatostatin receptors using 123I-Tyr-octreotide (30).”
MethodReubi, J. C., & Waser, B. (2003) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-003-1184-3 · Cited by 592 · cited 3×
“Sensitivity and specificity of 68Ga-DOTATOC and 68Ga-DOTATATE PET in patients with NETs were obtained from individual studies on a per-patient-based 390 Acta Radiologica 55(4)”
BackgroundMethodClassification and nomenclature of somatostatin receptors
Hoyer, D., Bell, G. I., Berelowitz, M., Epelbaum, J., Feniuk, W., Humphrey, P. P. A., O'Carroll, A.-M., Patel, Y. C., Schonbrunn, A., Taylor, J. E., et al. (1995) · Trends in Pharmacological Sciences · doi:10.1016/s0165-6147(00)88988-9 · Cited by 570 · cited 1×
“To date, five receptor subtypes have been recognized (3).”
BackgroundBuchmann, I., Henze, M., Engelbrecht, S., Eisenhut, M., Runz, A., Schäfer, M., Schilling, T., Haufe, S., Herrmann, T., & Haberkorn, U. (2007) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-007-0450-1 · Cited by 506 · cited 2×
“Therefore, 68Ga-DOTATOC can guide clinical management (6).”
Background
Cited by
Sundin, A., Arnold, R., Baudin, E., Cwikla, J. B., Eriksson, B., Fanti, S., Fazio, N., Giammarile, F., Hicks, R. J., Kjaer, A., et al. (2017) · Neuroendocrinology · doi:10.1159/000471879 · Cited by 501
Appropriate Use Criteria for Somatostatin Receptor PET Imaging in Neuroendocrine Tumors
Hope, T. A., Bergsland, E. K., Bozkurt, M. F., Graham, M., Heaney, A. P., Herrmann, K., Howe, J. R., Kulke, M. H., Kunz, P. L., Mailman, J., et al. (2018) · Journal of Nuclear Medicine · doi:10.2967/jnumed.117.202275 · Cited by 363
Sadowski, S. M., Neychev, V., Millo, C., Shih, J., Nilubol, N., Herscovitch, P., Pacak, K., Marx, S. J., & Kebebew, E. (2016) · Journal of Clinical Oncology · doi:10.1200/jco.2015.64.0987 · Cited by 353
Deppen, S. A., Blume, J., Bobbey, A. J., Shah, C., Graham, M. M., Lee, P., Delbeke, D., & Walker, R. C. (2016) · Journal of Nuclear Medicine · doi:10.2967/jnumed.115.165803 · Cited by 264
Consensus on molecular imaging and theranostics in neuroendocrine neoplasms
Ambrosini, V., Kunikowska, J., Baudin, E., Bodei, L., Bouvier, C., Capdevila, J., Cremonesi, M., de Herder, W. W., Dromain, C., Falconi, M., et al. (2021) · European Journal of Cancer · doi:10.1016/j.ejca.2021.01.008 · Cited by 244
Johnbeck, C. B., Knigge, U., Loft, A., Berthelsen, A. K., Mortensen, J., Oturai, P., Langer, S. W., Elema, D. R., & Kjaer, A. (2017) · Journal of Nuclear Medicine · doi:10.2967/jnumed.116.180430 · Cited by 243
“In contrast, a metaanalysis from 2014 found a higher patient-based sensitivity and specificity for 68Ga-DOTATATE than for 68Ga-DOTATOC (28).”
ResultBarrio, M., Czernin, J., Fanti, S., Ambrosini, V., Binse, I., Du, L., Eiber, M., Herrmann, K., & Fendler, W. P. (2017) · Journal of Nuclear Medicine · doi:10.2967/jnumed.116.185587 · Cited by 205
Deroose, C. M., Hindié, E., Kebebew, E., Goichot, B., Pacak, K., Taïeb, D., & Imperiale, A. (2016) · Journal of Nuclear Medicine · doi:10.2967/jnumed.116.179234 · Cited by 158
“A recent metaanalysis (24) concluded that both 68Ga-DOTATOC and 68Ga-DOTATATE have high diagnostic accuracy (sensitivity of 93% and 96%, respectively, and specificity of 85% and 100%, respectively).”
Background
Metadata
- Authors
- Yang, J., Kan, Y., Ge, B. H., Yuan, L., Li, C., & Zhao, W.
- Venue
- Acta Radiologica
- Publisher
- SAGE Publications
- Published
- 2014-05
- Volume
- 55
- Issue
- 4
- Pages
- 389-398
- ISSN
- 0284-1851 (ISSN-L)
- 1600-0455
- OpenAlex
- W2324995181
- Cited by
- 170
- References
- 35
- FWCI
- 2.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.