CoChat

Standardization of hippocampus volumetry using automated brain structure volumetry tool for an initial Alzheimer’s disease imaging biomarker

Abrigo, Jill, Shi, Lin, Luo, Yishan, Chen, Qianyun, Chu, Winnie Chiu Wing, Mok, Vincent Chung Tong, for the Alzheimer’s Disease Neuroimaging Initiative · 2019 · Acta Radiologica
Cited by 61

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Background: One significant barrier to incorporate Alzheimer’s disease (AD) imaging biomarkers into diagnostic criteria is the lack of standardized methods for biomarker quantification. The European Alzheimer’s Disease Consortium-Alzheimer’s Disease Neuroimaging Initiative (EADC-ADNI) Harmonization Protocol project provides the most authoritative guideline for hippocampal definition and has produced a manually segmented reference dataset for validation of automated methods. Purpose: To validate automated hippocampal volumetry using AccuBrain™, against the EADC-ADNI dataset, and assess its diagnostic performance for differentiating AD and normal aging in an independent cohort. Material and Methods: The EADC-ADNI reference dataset comprise of manually segmented hippocampal labels from 135 volumetric T1-weighted scans from various scanners. Dice similarity coefficient (DSC), intraclass correlation coefficient (ICC), and Pearson’s r were obtained for AccuBrain™ and FreeSurfer. The magnetic resonance imaging (MRI) of a separate cohort of 299 individuals (150 normal controls, 149 with AD) were obtained from the ADNI database and processed with AccuBrain™ to assess its diagnostic accuracy. Area under the curve (AUC) for total hippocampal volumes (HV) and hippocampal fraction (HF) were determined. Results: Compared with EADC-ADNI dataset ground truths, AccuBrain™ had a mean DSC of 0.89/0.89/0.89, ICC of 0.94/0.96/0.95, and r of 0.95/0.96/0.95 for right/left/total HV. AccuBrain™ HV and HF had AUC of 0.76 and 0.80, respectively. Thresholds of ≤ 5.71 mL and ≤ 0.38% afforded 80% sensitivity for AD detection. Conclusion: AccuBrain™ provides accurate automated hippocampus segmentation in accordance with the EADC-ADNI standard, with great potential value in assisting clinical diagnosis of AD.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/0284185118795327

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 61

Metadata

Authors
Abrigo, J., Shi, L., Luo, Y., Chen, Q., Chu, W. C. W., Mok, V. C. T., & Initiative, F. T. A. D. N.
Venue
Acta Radiologica
Published
2018-09-05
Volume
60
Issue
6
Pages
769-776
ISSN
  • 0284-1851 (ISSN-L)
  • 1600-0455
OpenAlex
W2890852374
Cited by
61
References
4
FWCI
5.03
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Standardization of hippocampus volumetry using automated brain structure volumetry tool for an initial Alzheimer’s disease imaging biomarker. https://app.cochat.ai/papers/10.1177/0284185118795327
The paper
Abrigo, J., Shi, L., Luo, Y., Chen, Q., Chu, W. C. W., Mok, V. C. T., & Initiative, F. T. A. D. N. (2019). Standardization of hippocampus volumetry using automated brain structure volumetry tool for an initial Alzheimer’s disease imaging biomarker. Acta Radiologica. https://doi.org/10.1177/0284185118795327

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.