Current methods of preventing aseptic loosening and improving osseointegration of titanium implants in cementless total hip arthroplasty: a review
Open accessThe DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.
Abstract
Hip osteoarthritis is the most common joint disorder, and is represented by a degenerative process, resulting in pain and functional impairment. If conservative treatment for hip osteoarthritis fails, the only remaining option is hip arthroplasty. Despite good survival of implants, loosening of components is the most common complication. This leads to revision surgeries, which are technically demanding, expensive, and result in a low satisfaction rate. Uncemented hip replacements require proper osseointegration for increased survival. Physical characteristics of implants include biocompatibility, Young’s modulus of elasticity, strength, and corrosion resistance, and each influence fixation of implants. Moreover, implant surface treatments, pore size, pore density, and femoral stem design should be appropriately selected. Patients’ optimization of obesity, osteoporosis, cardiovascular disease, psychotic disorders, and smoking cessation are associated with a higher survival of implants. Surgical factors, such as approach, drilling and rasping, acetabular bone coverage, acetabular cup positioning, and implant size, also affect survival of implants. Avoiding drugs, which may impair osseointegration of implants, and having an appropriate rehabilitation protocol are important. Future directions include anabolic and anti-catabolic bone-acting drugs to enhance osseointegration of implants. Comprehensive knowledge of the factors mentioned above is important for preventing aseptic loosening, with important socioeconomic consequences.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intermolecular and Surface Forces
(2011) · Intermolecular and Surface Forces · doi:10.1016/b978-0-12-391927-4.10024-6 · Cited by 16,923
The Glossary of Prosthodontic Terms
(2005) · The Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2005.03.013 · Cited by 1,323
Møller, A. M., Villebro, N., Pedersen, T., & Tønnesen, H. (2002) · The Lancet · doi:10.1016/s0140-6736(02)07369-5 · Cited by 1,126
Biomedical applications of titanium and its alloys
Elias, C. N., Lima, J. H. C., Valiev, R., & Meyers, M. A. (2008) · JOM · doi:10.1007/s11837-008-0031-1 · Cited by 983 · cited 2×
“Toxic-free element alloys, such as Ti-13Nb-13Zr, Ti-12Mo6Zr, and Ti-12Mo-6Zr-2Fe, could be preferred in future medical use.(17,26) The alloys mentioned above are still under development for orthopaedic use.”
Taniguchi, N., Fujibayashi, S., Takemoto, M., Sasaki, K., Otsuki, B., Nakamura, T., Matsushita, T., Kokubo, T., & Matsuda, S. (2016) · Materials Science and Engineering: C · doi:10.1016/j.msec.2015.10.069 · Cited by 960
Biocompatibility of Advanced Manufactured Titanium Implants—A Review
Sidambe, A. (2014) · Materials · doi:10.3390/ma7128168 · Cited by 741 · cited 1×
“The most important property of titanium regarding osseointegration is due to a low electrical conductivity, which leads to formation of an oxide layer.(19) This facilitates adhesion of osteoblasts to the surface of titanium and produces better implant fixation compared with other metals.”
Biology of implant osseointegration.
Mavrogenis, A., Dimitriou, R. I., Parvizi, J., & Babis, G. C. (2009) · PubMed · Cited by 639
Surface Modifications and Their Effects on Titanium Dental Implants
Jemat, A., Ghazali, M. J., Razali, M., & Otsuka, Y. (2015) · BioMed Research International · doi:10.1155/2015/791725 · Cited by 611 · cited 7×
“A review by Mavrogenis et al.31 showed that enoxaparin, warfarin, dalteparin, and unfractionated heparin are factors that may inhibit titanium osseointegration, by supressing osteoblast activity in cell cultures.6 However, fondaparinux does not show a negative effect on implant fixation.31 Moreover, previous studies h…”
InfluentialHailer, N. P., Garellick, G., & Kärrholm, J. (2010) · Acta Orthopaedica · doi:10.3109/17453671003685400 · Cited by 458 · cited 1×
“Although survival rates of cementless titanium implants at 10 years are satisfactory (85%), this rate decreases to 70% at 15 years.(9) The most common cause for failure of implants is impaired implant fixation (76%), called aseptic loosening.”
Vanhegan, I. S., Malik, A. K., Jayakumar, P., Islam, S. U., & Haddad, F. S. (2012) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.94b5.27073 · Cited by 362
The effects on bone cells of metal ions released from orthopaedic implants. A review
Sansone, V (2013) · CLINICAL CASES IN MINERAL AND BONE METABOLISM · doi:10.11138/ccmbm/2013.10.1.034 · Cited by 289 · cited 2×
“, amyotrophic lateral sclerosis or Parkinson’s disease), while vanadium can produce cellular mutations.(27) The ideal metal that is used in hip replacement implants should have the Figure 3.”
Wassmann, T., Kreis, S., Behr, M., & Buergers, R. (2017) · International Journal of Implant Dentistry · doi:10.1186/s40729-017-0093-3 · Cited by 252 · cited 1×
“Studies have reported an increase in Staphylococcus epidermidis with increased implant wettability and in Streptococcus sanguinis when a more porous surface is used.(44) As soon as bacteria colonize the titanium implant, they form a complex of microbial cells contained in an extracellular matrix, called biofilm.”
Titanium as a Biomaterial for Implants
Oldani, C. R., & Domínguez, A. (2012) · InTech eBooks · doi:10.5772/27413 · Cited by 240 · cited 4×
“The titanium alloy Ti6AL-4V has a Young modulus of 110 GPa,(21) whereas stainless steel is approximately 180 GPa.(18) Besides alloy composition, implant structure can also affect Young’s modulus.”
InfluentialWhat Host Factors Affect Aseptic Loosening After THA and TKA?
Cherian, J. J., Jauregui, J. J., Banerjee, S., Pierce, T., & Mont, M. A. (2015) · Clinical Orthopaedics & Related Research · doi:10.1007/s11999-015-4220-2 · Cited by 205 · cited 1×
“Avoiding high impact activities is associated with a decrease in aseptic loosening.(74)”
Lewallen, E. A., Riester, S. M., Bonin, C. A., Kremers, H. M., Dudakovic, A., Kakar, S., Cohen, R. C., Westendorf, J. J., Lewallen, D. G., & van Wijnen, A. J. (2015) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2014.0333 · Cited by 186 · cited 1×
“Titanium offers the best strength-to-weight ratio of all metals, and this ratio is over 50% higher than that of steel.(24,25) Addition of elements make titanium alloys more resistant to ultimate tensile strength (ability to withstand a pulling force), yield strength (force required to induce permanent deformation), an…”
Risk Factors for Total Knee Arthroplasty Aseptic Revision
Namba, R. S., Cafri, G., Khatod, M. X., Inacio, M. C. S., Brox, T. W., & Paxton, E. W. (2013) · The Journal of Arthroplasty · doi:10.1016/j.arth.2013.04.050 · Cited by 151
Patient expectation and satisfaction in revision total hip arthroplasty
Eisler, T., Svensson, O., Tengström, A., & Elmstedt, E. (2002) · The Journal of Arthroplasty · doi:10.1054/arth.2002.31245 · Cited by 142 · cited 1×
“Total hip replacement failure is treated with revision surgeries, which are technically demanding, have a high complication rate,(3) are expensive,(13) and usually result in a low satisfaction rate for patients.(14) Methods of improving implant fixation include choice of implant, preoperative Apostu et al.”
Wu, X., Al‐Abedalla, K., Rastikerdar, E., Nader, S. A., Daniel, N. G., Nicolau, B. F., & Tamimi, F. (2014) · Journal of Dental Research · doi:10.1177/0022034514549378 · Cited by 136 · cited 1×
“SSRIs are associated with an increased risk of implant failure,(76) by acting on a serotonin transporter (5-HTT) on bone cells with a negative effect on bone formation.(77) Such a treatment is recommended to be replaced in patients with a hip replacement.”
Cemented, cementless, and hybrid prostheses for total hip replacement: cost effectiveness analysis
Pennington, M., Grieve, R., Sekhon, J. S., GREGG, P. J., Black, N. A., & van der Meulen, J. (2013) · BMJ · doi:10.1136/bmj.f1026 · Cited by 134 · cited 1×
“Titanium implants have two methods of fixation of either using cement (cemented total hip replacements) or by bone ingrowth (cementless total hip replacements).(4) Cementless total hip replacements involve bone apposition on titanium implants, a process called osseointegration.”
Systemic drugs that influence titanium implant osseointegration
Apostu, D., LUCACIU, O. P., Lucaciu, G. D. O., Crisan, B. V., Crişan, L., Băciuț, M. F., Onisor, F. G., Băciuț, G., Câmpian, R. S., & Bran, S. (2017) · Drug Metabolism Reviews · doi:10.1080/03602532.2016.1277737 · Cited by 118 · cited 5×
“Systemic drugs are classified by their effect on bone into the following: anabolic (parathyroid hormone peptides, prostaglandin EP4 receptor antagonists, vitamin D, DKK1 antibody, and anti-sclerostin antibody), anti-catabolic (calcitonin, bisphosphonates, the RANK/RANKL/ OPG system, and selective oestrogen receptor mo…”
InfluentialSelf-citationWu, X., Al‐Abedalla, K., Eimar, H. A., Madathil, S. A., Abi‐Nader, S., Daniel, N. G., Nicolau, B. F., & Tamimi, F. (2016) · Clinical Implant Dentistry and Related Research · doi:10.1111/cid.12414 · Cited by 103 · cited 1×
“Antihypertensive drugs have not been associated with an increase in aseptic loosening, and thus are considered safe to use.(80)”
Jämsen, E., Peltola, M., Eskelinen, A. P., & Lehto, M. U. K. (2012) · Annals of the Rheumatic Diseases · doi:10.1136/annrheumdis-2012-202064 · Cited by 102 · cited 2×
“performed on 96,754 patients with primary hip and knee osteoarthritis.(53) However, we”
Teng, S., Yi, C., Krettek, C., & Jagodzinski, M. (2015) · PLoS ONE · doi:10.1371/journal.pone.0125294 · Cited by 101
Friedl, G., Radl, R., Stihsen, C., Rehak, P., Aigner, R., & Windhager, R. H. (2009) · Journal of Bone and Joint Surgery · doi:10.2106/jbjs.g.01193 · Cited by 93 · cited 2×
“Zoledronic acid was also proven to be beneficial in preventing aseptic loosening in hip replacements by a clinical trial performed by Friedl et al.68 However, pamidronate does not affect cup migration.69 With regard to newer treatments, human anti-RANKL antibodies represented by denosumab are undergoing a clinical tri…”
Wegrzyn, J., Kaufman, K. R., Hanssen, A. D., & Lewallen, D. G. (2015) · The Journal of Arthroplasty · doi:10.1016/j.arth.2015.01.013 · Cited by 93 · cited 1×
“monoblock cups.(39) Because of the high cost, porous tantalum is currently most frequently used in revision hip replacements.”
Sköldenberg, O. G., Salemyr, M., Bodén, H. S. G., Ahl, T., & Adolphson, P. (2011) · Journal of Bone and Joint Surgery · doi:10.2106/jbjs.j.01646 · Cited by 90 · cited 2×
“One trial was performed by Skӧldenberg et al.(66) regarding risedronate, which is a bisphosphonate.”
Jing, D., Zhai, M., Tong, S., Xu, F., Cai, J., Shen, G., Wu, Y., Li, X., Xie, K., Liu, J., et al. (2016) · Scientific Reports · doi:10.1038/srep32045 · Cited by 81 · cited 1×
“Pulsed electromagnetic fields are another approach, which increases osseointegration in an animal model by promoting bone anabolic metabolism.(83) There have been no clinical trials regarding this method.”
Kapadia, B. H., Issa, K., Pivec, R., Bonutti, P. M., & Mont, M. A. (2013) · The Journal of Arthroplasty · doi:10.1016/j.arth.2013.08.023 · Cited by 79 · cited 1×
“With regard to smoking cessation, former smokers (nonsmokers within 30 days before surgery) have no difference in complications compared with current smokers, at a mean follow-up of four years.(56) Therefore, smoking cessation before surgery is not related to short- and medium-term titanium implant loosening.”
The type of surgical approach influences the risk of revision in total hip arthroplasty
Lindgren, V., Garellick, G., Kärrholm, J., & Wretenberg, P. F. (2012) · Acta Orthopaedica · doi:10.3109/17453674.2012.742394 · Cited by 78
Aseptic Loosening Rates in Distal Femoral Endoprostheses: Does Stem Size Matter?
Bergin, P. F., Noveau, J., Jelinek, J. S., & Henshaw, R. M. (2011) · Clinical Orthopaedics and Related Research · doi:10.1007/s11999-011-2081-x · Cited by 76 · cited 3×
“Apart from inclination, good containment of the cup in the acetabular cavity is essential to ensure good bone ingrowth.63 Stem size can predict implant survival, as suggested by Bergin et al.64.”
InfluentialWilkinson, J. M., Eagleton, A. C., Stockley, I., Peel, N. F. A., Hamer, A. J., & Eastell, R. (2004) · Journal of Orthopaedic Research® · doi:10.1016/j.orthres.2004.06.004 · Cited by 73 · cited 1×
“However, pamidronate does not affect cup migration.(69) With regard to newer treatments, human anti-RANKL antibodies represented by denosumab are undergoing a clinical trial for treating periprosthetic osteolysis.”
Biologic fixation of total hip implants. Insights gained from a series of canine studies.
Bragdon, C. R., Jasty, M., Greene, M. E., Rubash, H. E., & Harris, W. H. (2004) · PubMed · Cited by 71
Dental follicle stem cells in bone regeneration on titanium implants
LUCACIU, O. P., Şoriţău, O., Gheban, D., Rus-Ciuca, D., Virtic, O., Vulpoi, A., Dîrzu, N., Câmpian, R. S., Băciuț, G., Popa, C. O., et al. (2015) · BMC Biotechnology · doi:10.1186/s12896-015-0229-6 · Cited by 71 · cited 1×
“Other techniques, such as bone tissue engineering using stem cells and scaffolds, are still under development.(15,16) This review discusses the current methods and their effect on osseointegration of titanium implants.”
Self-citationChen, Y.-L., Lin, T., Liu, A., Shi, M., Hu, B., Shi, Z., & Yan, S.-G. (2015) · Journal of Orthopaedic Surgery and Research · doi:10.1186/s13018-015-0161-4 · Cited by 67 · cited 2×
“A meta-analysis comparing these two types of coatings showed a lower incidence of aseptic loosening in the hydroxyapatite coating group than in the porous coating group.(32) Kim et al.”
Biofilm Disrupting Technology for Orthopedic Implants: What’s on the Horizon?
Connaughton, A., Childs, A., Dylewski, S., & Sabesan, V. J. (2014) · Frontiers in Medicine · doi:10.3389/fmed.2014.00022 · Cited by 67 · cited 3×
“As soon as bacteria colonize the titanium implant, they form a complex of microbial cells contained in an extracellular matrix, called biofilm.(45) Biofilm is more likely to form on rough and hydrophobic surfaces, but some bacteria can be more adherent to hydrophobic surfaces.”
John, A., Jaganathan, S. K., Supriyanto, E., & Manikandan, A. (2016) · Current Science · doi:10.18520/cs/v111/i6/1003-1015 · Cited by 65 · cited 3×
“The most common technique is surface coating and acid etching, with proven enhancement in osseointegration.(30) Hydroxyapatite and porous coatings are currently the most commonly used treatments.”
Rahyussalim, A. J., Marsetio, A. F., Saleh, I., Kurniawati, T., & Whulanza, Y. (2016) · Journal of Nanomaterials · doi:10.1155/2016/5386924 · Cited by 63 · cited 1×
“9Sn (TNZS) and Ti6Al7Nb alloys have better fixation and bone-toimplant contact.(28,29) Ti-35Nb-4Sn and TNZS have a Young modulus of approximately 40 GPa, which closely matches the bone’s elasticity properties, and thus prevents stress shielding.”
Risk Factors for Total Hip Arthroplasty Aseptic Revision
Khatod, M., Cafri, G., Namba, R. S., Inacio, M. C. S., & Paxton, E. W. (2014) · The Journal of Arthroplasty · doi:10.1016/j.arth.2014.01.023 · Cited by 61 · cited 1×
“have no effect on hip titanium implant survival.(53,54) Smoking increases the risk of aseptic loosening by three times as shown by a meta-analysis by Teng et al.”
Osseointegration: a review of the fundamentals for assuring cementless skeletal fixation
Isaacson, B. M., & Jeyapalina, S. (2014) · Orthopedic Research and Reviews · doi:10.2147/orr.s59274 · Cited by 57
Titanium Alloys in Orthopaedics
Wang, W., & Khoon, C. (2013) · InTech eBooks · doi:10.5772/55353 · Cited by 51
Wolf, O., Mattsson, P., Milbrink, J., Larsson, S., & Mallmin, H. (2010) · Acta Orthopaedica · doi:10.3109/17453674.2010.487238 · Cited by 48 · cited 2×
“Wolf et al.71 showed no difference in bone mineral density around implants when they compared immediate full weight bearing and partial weight bearing in cementless titanium total hip replacements at 5 years.”
Brie, I. C., Şoriţău, O., Dîrzu, N., Berce, C., Vulpoi, A., Popa, C. O., Todea, M., Şimon, S., Perde‐Schrepler, M., Virág, P., et al. (2014) · Journal of Biological Engineering · doi:10.1186/1754-1611-8-14 · Cited by 40
Self-citationOnce-weekly oral medication with alendronate does not prevent migration of knee prostheses
Hansson, U., Toksvig‐Larsen, S., Ryd, L., & Aspenberg, P. (2009) · Acta Orthopaedica · doi:10.1080/17453670902804968 · Cited by 34 · cited 2×
“In a clinical trial, Hansson et al.67 showed that the alendronate-treated group had no enhancement of fixation in uncemented knee arthroplasties compared with the control group.”
Kremers, H. M., Lewallen, E. A., van Wijnen, A. J., & Lewallen, D. G. (2016) · Current Molecular Biology Reports · doi:10.1007/s40610-016-0042-6 · Cited by 28 · cited 2×
“Moreover, patients with a body mass index greater than 35 kg/m(2) have double the incidence of titanium implant aseptic loosening following a total hip replacement.(50) This is one of the main reasons, along with an increased risk of prosthetic joint infection, for doctors to include weight loss in their preoperative…”
Porous c.p. Titanium Using Dextrin as Space Holder for Endosseous Implants
Gligor, I., Şoriţău, O., Todea, M., Berce, C., Vulpoi, A., Marcu, T., Cernea, V., Şimon, S., & Popa, C. O. (2012) · Particulate Science And Technology · doi:10.1080/02726351.2012.749556 · Cited by 27 · cited 1×
“Particularly, a porous structure can be adjusted to resemble that of bone.(22) The elasticity modulus can also affect survival of implants.”
Self-citationSköldenberg, O. G., Rysinska, A. D., Eisler, T., Salemyr, M., Bodén, H. S. G., & Muren, O. (2016) · BMC Musculoskeletal Disorders · doi:10.1186/s12891-016-1036-5 · Cited by 25 · cited 1×
“With regard to newer treatments, human anti-RANKL antibodies represented by denosumab are undergoing a clinical trial for treating periprosthetic osteolysis.(70)”
Effects of Low‐Intensity Pulsed Ultrasound on Implant Osseointegration in Ovariectomized Rats
Zhou, H., Hou, Y., Zhu, Z., et al. (2016) · Journal of Ultrasound in Medicine · doi:10.7863/ultra.15.01083 · Cited by 23
LUCACIU, O. P., Crisan, B. V., Crişan, L., Băciuț, M. F., Şoriţău, O., Bran, S., Biris, A. R., Hurubeanu, L., Hedesiu, M. C., Văcăraș, S., et al. (2015) · Drug Metabolism Reviews · doi:10.3109/03602532.2015.1124889 · Cited by 8 · cited 1×
“Other techniques, such as bone tissue engineering using stem cells and scaffolds, are still under development.(15,16) This review discusses the current methods and their effect on osseointegration of titanium implants.”
Self-citation
Metadata
- Authors
- Apostu, D., Lucaciu, O., Berce, C., Lucaciu, D., & Cosma, D.
- Venue
- Journal of International Medical Research
- Publisher
- SAGE Publications
- Published
- 2017-11-03
- Volume
- 46
- Issue
- 6
- Pages
- 2104-2119
- ISSN
- 0300-0605 (ISSN-L)
- 1473-2300
- OpenAlex
- W2765492391
- Cited by
- 236
- References
- 48
- FWCI
- 11.88
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.