The DOI matches its Crossref record.
Biocompatibility of Advanced Manufactured Titanium Implants—A Review
Open accessAbstract
Titanium (Ti) and its alloys may be processed via advanced powder manufacturing routes such as additive layer manufacturing (or 3D printing) or metal injection moulding. This field is receiving increased attention from various manufacturing sectors including the medical devices sector. It is possible that advanced manufacturing techniques could replace the machining or casting of metal alloys in the manufacture of devices because of associated advantages that include design flexibility, reduced processing costs, reduced waste, and the opportunity to more easily manufacture complex or custom-shaped implants. The emerging advanced manufacturing approaches of metal injection moulding and additive layer manufacturing are receiving particular attention from the implant fabrication industry because they could overcome some of the difficulties associated with traditional implant fabrication techniques such as titanium casting. Using advanced manufacturing, it is also possible to produce more complex porous structures with improved mechanical performance, potentially matching the modulus of elasticity of local bone. While the economic and engineering potential of advanced manufacturing for the manufacture of musculo-skeletal implants is therefore clear, the impact on the biocompatibility of the materials has been less investigated. In this review, the capabilities of advanced powder manufacturing routes in producing components that are suitable for biomedical implant applications are assessed with emphasis placed on surface finishes and porous structures. Given that biocompatibility and host bone response are critical determinants of clinical performance, published studies of in vitro and in vivo research have been considered carefully. The review concludes with a future outlook on advanced Ti production for biomedical implants using powder metallurgy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Schlundt, C., Fischer, H., Bucher, C. H., Rendenbach, C., Duda, G. N., & Schmidt-Bleek, K. (2021) · Acta Biomaterialia · doi:10.1016/j.actbio.2021.04.052 · Cited by 415
General review of titanium toxicity
Kim, K. T., Eo, M. Y., Nguyen, T. T. H., & Kim, S. M. (2019) · International Journal of Implant Dentistry · doi:10.1186/s40729-019-0162-x · Cited by 404
Mahmood, M. A., Chioibasu, D., Ur Rehman, A., Mihai, S., & Popescu, A. C. (2022) · Metals · doi:10.3390/met12010077 · Cited by 119
Wang, H., Yuan, C., Lin, K., Zhu, R., & Zhang, S. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.761911 · Cited by 16
Metadata
- Authors
- Sidambe, A.
- Venue
- Materials
- Publisher
- MDPI AG
- Published
- 2014-12-19
- Volume
- 7
- Issue
- 12
- Pages
- 8168-8188
- ISSN
- 1996-1944 (ISSN-L)
- OpenAlex
- W2129012148
- Cited by
- 741
- References
- 0
- FWCI
- 8.34
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Biocompatibility of Advanced Manufactured Titanium Implants—A Review. https://app.cochat.ai/papers/10.3390/ma7128168
- The paper
- Sidambe, A. (2014). Biocompatibility of Advanced Manufactured Titanium Implants—A Review. Materials. https://doi.org/10.3390/ma7128168
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.