CoChat

A review of the principles of turbidity measurement

Open access
Kitchener, Ben GB, Wainwright, John, Parsons, Anthony J · 2017 · Progress in Physical Geography: Earth and Environment
Cited by 175

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Turbidity of water due to the presence of suspended sediment is measured and interpreted in a variety of ways, which can lead to the misinterpretation of data. This paper re-examines the physics of light scattering in water, and exposes the extent to which the reporting of turbidity data is inconsistent. It is proposed that the cause of this inconsistency is the fact that the accepted turbidity standards USEPA Method 180.1, ISO 7027 and GLI Method 2 are mutually inconsistent, as these standards give rise to a large number of measurement units that are not based on the optical properties of light absorption and scattering by suspensions in water, but by the arbitrary definition of the degree of turbidity being due to a concentration of formazin or other similar polymer-based calibration standard. It is then proposed that all turbidity-measuring devices should be calibrated with precise optical attenuators such as neutral density filters. Such calibration would allow for the definition of a beam attenuation coefficient for every turbidity-measuring instrument which would be cross-comparable with any other instrument calibrated in the same way. The units for turbidity measurements should be based on attenuation and reported as dB m−1. It is also proposed that a new standard should be drafted according to this attenuation-based method, and this new standard should also define the nomenclature for reporting data collected at any specific scattering angle in terms of an attenuation in dB m−1. The importance of multi-parameter turbidity measurements for the improvement of the quality of turbidity data and the application of parameter-rich data sets to new methods of sediment characterization are discussed. It is suggested that more research into multi-parameter turbidity measurements is needed, as these new methods will facilitate an increase in parity between turbidity and suspended sediment concentration, a relationship that is subjective.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/0309133317726540

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

  • Large language models for chemistry robotics

    Yoshikawa, N., Skreta, M., Darvish, K., Arellano-Rubach, S., Ji, Z., Bjørn Kristensen, L., Li, A. Z., Zhao, Y., Xu, H., Kuramshin, A., et al. (2023) · Autonomous Robots · doi:10.1007/s10514-023-10136-2 · Cited by 112

    “In our work, we use the turbidity measure (Shiri et al., 2021), which is based on optical properties of light scattering and absorption by suspended sediment (Kitchener et al., 2017).”
    BackgroundMethod

See all 175

Metadata

Authors
Kitchener, B. G., Wainwright, J., & Parsons, A. J.
Venue
Progress in Physical Geography: Earth and Environment
Published
2017-08-23
Volume
41
Issue
5
Pages
620-642
ISSN
  • 0309-1333 (ISSN-L)
  • 1477-0296
OpenAlex
W2750411879
Cited by
175
References
2
FWCI
5.60
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A review of the principles of turbidity measurement. https://app.cochat.ai/papers/10.1177/0309133317726540
The paper
Kitchener, B. G., Wainwright, J., & Parsons, A. J. (2017). A review of the principles of turbidity measurement. Progress in Physical Geography: Earth and Environment. https://doi.org/10.1177/0309133317726540

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.