Cited by 73Anesthesia and Sedative AgentsBiomedical and Chemical ResearchGlobal Health and Surgery

The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.

Financial and Environmental Costs of Manual versus Automated Control of End-Tidal Gas Concentrations

Tay, S., Weinberg, L., Peyton, P., Story, D., Briedis, J.·2013·Anaesthesia and Intensive Care

Abstract

Emerging technologies that reduce the economic and environmental costs of anaesthesia have had limited assessment. We hypothesised that automated control of end-tidal gases, a new feature in anaesthesia machines, will consistently reduce volatile agent consumption cost and greenhouse gas emissions. As part of the planned replacement of anaesthesia machines in a tertiary hospital, we performed a prospective before and after study comparing the cost and greenhouse gas emissions of isoflurane, sevoflurane and desflurane when using manual versus automated control of end-tidal gases. We analysed 3675 general anaesthesia cases with inhalational agents: 1865 using manual control and 1810 using automated control. Volatile agent cost was $18.87/hour using manual control and $13.82/hour using automated control: mean decrease $5.05/hour (95% confidence interval: $0.88–9.22/hour, P=0.0243). The 100-year global warming potential decreased from 23.2 kg/hour of carbon dioxide equivalents to 13.0 kg/hour: mean decrease 10.2 kg/hour (95% confidence interval: 2.7–17.7 kg/hour, P=0.0179). Automated control reduced costs by 27%. Greenhouse gas emissions decreased by 44%, a greater than expected decrease facilitated by a proportional reduction in desflurane use. Automated control of end-tidal gases increases participation in low-flow anaesthesia with economic and environmental benefits.

Overview

Integrity signals

Registry

Crossref · 10.1177/0310057x1304100116

Cites

27 of 27 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Switching from conventional fresh gas mode to an electronically controlled mode is associated with lower consumption of inhalational anesthetics, costs, and GHG emissions.

    “Switching from conventional fresh gas mode to an electronically controlled mode such as “auto control” (Zeus IE®, Drägerwerk AG & Co. KGaA, Lübeck, Germany), “end-tidal control” (Aisys CS2®, General Electric Company, Boston, MA, USA), or “automated gas control” (FLOW-i®, Maquet, Solna, Sweden) is associated with lower consumption of inhalational anesthetics, costs, and GHG emissions.49”

Citations

Cites

Flagged first, then by citations

Research works printed but not linked: 1

  1. De Cooman S., 2009, Acta Anaesthesiol Belg, 60, 35

Cited by

Sorted by citations

Metadata

Authors
Tay, S., Weinberg, L., Peyton, P., Story, D., & Briedis, J.
Affiliations
  • Northern Health (AU)
  • The University of Melbourne (AU)
Corresponding author
Tay, S.
Venue
Anaesthesia and Intensive Care
Published
2013-01
Volume
41
Issue
1
Pages
95-101
ISSN
  • 0310-057X (ISSN-L)
  • 1448-0271
OpenAlex
W158752778
Cited by
73
References
27
Citations by year
2026: 7 · 2025: 15 · 2024: 11 · 2023: 9 · 2022: 5 · 2021: 3 · 2019: 7 · 2017: 3 · 2016: 3 · 2015: 1 · 2014: 7 · 2013: 2
FWCI
5.54
Type
journal article
Language
en
Open access
closed
Locations
  • Anaesthesia and Intensive Care (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Anesthesiology and Pain Medicine › Anesthesia and Sedative Agents
  • Health Sciences › Medicine › Physiology (medical) › Biomedical and Chemical Research
  • Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Global Health and Surgery
Keywords
anesthesia machines, volatile anesthetics, isoflurane, sevoflurane, desflurane, anesthesia costs, greenhouse gas emissions, global warming potential, low-flow anesthesia, environmental impact of anesthesia
MeSH terms
Sevoflurane, Desflurane, Adolescent, Adult, Aged, Aged, 80 and over, Anesthesia, General, Automation, Carbon Dioxide, Child, Child, Preschool, Female, Hospitals, University, Humans, Infant, Isoflurane, Male, Methyl Ethers, Middle Aged, Prospective Studies, Drug Costs, Greenhouse Effect, Anesthetics, Inhalation, Young Adult, Global Warming

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review