The Pulse Oximeter: Applications and Limitations—An Analysis of 2000 Incident Reports
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The first 2000 incidents reported to the Australian Incident Monitoring Study were analysed with respect to the role of the pulse oximeter. Of these 184 (9%) were first detected by a pulse oximeter and there were a further 177 (9%) in which desaturation was recorded. Of the 1256 incidents which occurred in association with general anaesthesia 48% were “human detected” and 52% “monitor detected”. The pulse oximeter was ranked first and detected 27% of these monitor detected incidents; this figure would have been over 40% if an oximeter had always been used and its more informative modulated pulse tone relied upon instead of that of the “bleep” of the ECG. The pulse oximeter is the “front-line” monitor for endobronchial intubation, the fourth most common incident in association with general anaesthesia (it detected 87% of the 76 cases in which it was in use). It also played an invaluable role as a “back-up” monitor in 40 life-threatening situations in which “front-line” monitors (e.g. oxygen analyser, low pressure alarm, capnograph) were either not in use, were being used incorrectly or failed. Other situations detected, in order of frequency of detection, were: circuit disconnection, circuit leak, desaturation (severe shunt), oesophageal intubation, aspiration and/or regurgitation, pulmonary oedema, endotracheal tube obstruction, severe hypotension, failure of oxygen delivery, hypoxic gas mixture, hypoventilation, anaphylaxis, air embolism, bronchospasm, malignant hyperthermia, and tension pneumothorax. There were 15 reports of “failure”; four because the model in use had no modulated tone or alarm, four in which performance was in fact adequate, three were probe problems, two involved “over-reading”, one “under-reading” and in one new device the alarm failed. In the theoretical analysis of the 1256 general anaesthesia incidents it was concluded that pulse oximetry, used on its own, would have detected 82% of these incidents, had they been allowed to evolve (nearly 60% before any potential for organ damage). It is highly recommended that a suitable pulse oximeter be used on all patients from the time of arrival in the induction room until return of protective reflexes and demonstration of adequate saturation when breathing room air.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Potential errors in pulse oximetry: I. Pulse oximeter evaluation*
RALSTON, A. C., WEBB, R. K., & RUNCIMAN, W. B. (1991) · Anaesthesia · doi:10.1111/j.1365-2044.1991.tb09410.x · Cited by 166
Self-citation
Cited by
Neumar, R. W., Otto, C. W., Link, M. S., Kronick, S. L., Shuster, M., Callaway, C. W., Kudenchuk, P. J., Ornato, J. P., McNally, B., Silvers, S. M., et al. (2010) · Circulation · doi:10.1161/circulationaha.110.970988 · Cited by 1,634
Adverse Sedation Events in Pediatrics: A Critical Incident Analysis of Contributing Factors
Coté, C. J., Notterman, D. A., Karl, H. W., Weinberg, J. A., & McCloskey, C. (2000) · Pediatrics · doi:10.1542/peds.105.4.805 · Cited by 593
Jubran, A. (2015) · Critical Care · doi:10.1186/s13054-015-0984-8 · Cited by 491
Jubran, A. (2004) · Intensive Care Medicine · doi:10.1007/s00134-004-2399-x · Cited by 401
The Australian Incident Monitoring Study: An Analysis of 2000 Incident Reports
Webb, R. K., Currie, M., Morgan, C. A., Williamson, J. A., Mackay, P., Russell, W. J., & Runciman, W. B. (1993) · Anaesthesia and Intensive Care · doi:10.1177/0310057x9302100507 · Cited by 352
Self-citation
Metadata
- Authors
- Runciman, W. B., Webb, R. K., Barker, L., & Currie, M.
- Venue
- Anaesthesia and Intensive Care
- Publisher
- SAGE Publications
- Published
- 1993-10
- Volume
- 21
- Issue
- 5
- Pages
- 543-550
- ISSN
- 0310-057X (ISSN-L)
- 1448-0271
- OpenAlex
- W2407488597
- Cited by
- 122
- References
- 1
- FWCI
- 8.57
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Pulse Oximeter: Applications and Limitations—An Analysis of 2000 Incident Reports. https://app.cochat.ai/papers/10.1177/0310057x9302100509
- The paper
- Runciman, W. B., Webb, R. K., Barker, L., & Currie, M. (1993). The Pulse Oximeter: Applications and Limitations—An Analysis of 2000 Incident Reports. Anaesthesia and Intensive Care. https://doi.org/10.1177/0310057x9302100509
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.