Another Look at Pedestrian Walking Speed
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Pedestrians have a wide range of needs and abilities. FHWA's Manual on Uniform Traffic Control Devices for Streets and Highways includes a walking speed of 4.0 ft/s (1.2 m/s) for calculating pedestrian clearance intervals for traffic signals. It also includes a comment that where pedestrians who walk slower than normal, or pedestrians who use wheelchairs, routinely use the crosswalk, a walking speed of less than 4.0 ft/s should be considered in determining the pedestrian clearance times. A 2005 TCRP-NCHRP study found a 15th percentile walking speed for young pedestrians of 3.77 ft/s (1.15 m/s) and a 15th percentile walking speed for older pedestrians of 3.03 ft/s (0.92 m/s). The study also determined that there is a statistical difference in walking speeds between older (older than 60 years) and younger (60 years and younger) pedestrians. Using population projections and the 15th percentile walking speeds for each population group more than 15 years old, the proportionally weighted 15th percentile walking speed for 2045 is 3.56 ft/s (1.09 m/s). Comparing the findings from the TCRP-NCHRP study with previous work results in the following recommendations: 3.5-ft/s (1.07-m/s) walking speed for timing of a traffic signal; if older pedestrians are a concern, then a 3.0-ft/s (0.9-m/s) walking speed should be used.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Transportation Research Record
Olesen, A. V., Kjems, E., Reinau, K. H., & Jensen, O. B. (2016) · Cited by 11,521
Field Studies of Pedestrian Walking Speed and Start-Up Time
Knoblauch, R. L., Pietrucha, M. T., & Nitzburg, M. (1996) · Transportation Research Record: Journal of the Transportation Research Board · doi:10.1177/0361198196153800104 · Cited by 571 · cited 4×
“TABLE 1 Findings on Walking Speeds at Signalized Intersections for Pedestrians Who Complied with the Pedestrian Signal Indication (6)”
BackgroundMethodInfluentialHuman factors in traffic safety
Dewar, R. E., & Olson, P. L. (2002) · Medical Entomology and Zoology · Cited by 323
Quality of Service for Interrupted-Flow Pedestrian Facilities in Highway Capacity Manual 2000
Milazzo, J. S., Rouphail, N. M., Hummer, J. E., et al. (1999) · Transportation Research Record Journal of the Transportation Research Board · doi:10.3141/1678-04 · Cited by 41 · cited 1×
“(8) reviewed past research and guidelines for pedestrian crossing speeds.”
BackgroundThe Safety of Elderly Pedestrians at Five Urban Intersections in Miami
Guerrier, J. H., & Jolibois, S. C. (1998) · Proceedings of the Human Factors and Ergonomics Society Annual Meeting · doi:10.1177/154193129804200206 · Cited by 28
Cited by
Designing thermoelectric generators for self-powered wearable electronics
Suarez, F., Nozariasbmarz, A., Vashaee, D., & Öztürk, M. C. (2016) · Energy & Environmental Science · doi:10.1039/c6ee00456c · Cited by 431
Suarez, F., Parekh, D. P., Ladd, C., Vashaee, D., Dickey, M. D., & Öztürk, M. C. (2017) · Applied Energy · doi:10.1016/j.apenergy.2017.05.181 · Cited by 317
Efficacy of virtual reality in pedestrian safety research
Deb, S., Carruth, D. W., Sween, R., Strawderman, L., & Garrison, T. M. (2017) · Applied Ergonomics · doi:10.1016/j.apergo.2017.03.007 · Cited by 281
Goel, M., Findlater, L., & Wobbrock, J. (2012) · Proceedings of the SIGCHI Conference on Human Factors in Computing Systems · doi:10.1145/2207676.2208662 · Cited by 203
“To simulate a routine and unconstrained environment, the pacesetter ensured that the walking speed was consistent at about 1.07 m/s (3.51 feet/s), a pace that comfortably accommodates a wide range of age and abilities [10].”
BackgroundInfluentialBehavioural Issues in Pedestrian Speed Choice and Street Crossing Behaviour: A Review
Ishaque, M. M., & Noland, R. B. (2008) · Transport Reviews · doi:10.1080/01441640701365239 · Cited by 165
“Wilson and Grayson (1980) have examined the relationship of pedestrian speed with age and gender.”
BackgroundMethodResultInfluential
Metadata
- Authors
- Fitzpatrick, K., Brewer, M. A., & Turner, S.
- Venue
- Transportation Research Record: Journal of the Transportation Research Board
- Publisher
- SAGE Publications
- Published
- 2006-01
- Volume
- 1982
- Issue
- 1
- Pages
- 21-29
- ISSN
- 0361-1981 (ISSN-L)
- 2169-4052
- OpenAlex
- W4245056847
- Cited by
- 178
- References
- 5
- FWCI
- 10.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.