The Fixation Strength of Six Hamstring Tendon Graft Fixation Devices in Anterior Cruciate Ligament Reconstruction: Part II: Tibial Site
The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
Background: Tibial fixation is more problematic than femoral fixation in anterior cruciate ligament reconstruction. Hypothesis: There is no difference in initial fixation strength among hamstring tendon graft tibial fixation devices. Study Design: Randomized experimental study. Methods: Each of six devices used to fix 120 quadrupled human semitendinosus-gracilis tendon grafts into porcine tibiae was tested 10 times with a single-cycle load-to-failure test and 10 times with a 1500-cycle loading test. Specimens surviving cyclic loading were subjected to a single-cycle load-to-failure test. Results: Intrafix (1332 N) was the strongest in the single-cycle load-to-failure test, followed by WasherLoc (975 N), tandem spiked washer (769 N), SmartScrew ACL (665 N), BioScrew (612 N), and SoftSilk (471 N). After cyclic-loading tests, Intrafix showed the lowest residual displacement (1.5 mm) and was also strongest (1309 N) in the single-cycle load-to-failure test after the cyclic-loading test, followed by WasherLoc (3.2 mm; 917 N). Conclusion: The Intrafix provided clearly superior strength in the fixation of hamstring tendon grafts to the tibial drill hole. Clinical Relevance: Some caution may be warranted when using the implants that showed increased residual displacement, especially if aggressive rehabilitation is to be used. Preconditioning of the hamstring tendon graft-implant complex before tibial fixation is needed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Effects of postmortem storage by freezing on ligament tensile behavior
Woo, S. L.-Y., Orlando, C. A., Camp, J. F., & Akeson, W. H. (1986) · Journal of Biomechanics · doi:10.1016/0021-9290(86)90016-3 · Cited by 572 · cited 1×
“These preservation procedures have no deleterious effect on the mechanical properties of the tendons or bones.(11,20) Preparation and testing were performed at room temperature, and the specimens were kept moist with saline spray throughout the study.”
Current Trends in Anterior Cruciate Ligament Reconstruction
Fu, F. H., Bennett, C. H., Lattermann, C., & Ma, C. B. (1999) · The American Journal of Sports Medicine · doi:10.1177/03635465990270062501 · Cited by 564
Graft Fixation in Cruciate Ligament Reconstruction
Brand, J., Weiler, A., Caborn, D. N. M., Brown, C. H., & Johnson, D. L. (2000) · The American Journal of Sports Medicine · doi:10.1177/03635465000280052501 · Cited by 436
Fu, F. H., Bennett, C. H., Ma, C. B., Menetrey, J., & Lattermann, C. (2000) · The American Journal of Sports Medicine · doi:10.1177/03635465000280010801 · Cited by 412
Effects of freezing and freeze‐drying on the biomechanical properties of rat bone
Pelker, R. R., Friedlaender, G. E., Markham, T. C., Panjabi, M. M., & Moen, C. J. (1983) · Journal of Orthopaedic Research · doi:10.1002/jor.1100010409 · Cited by 266 · cited 1×
“These preservation procedures have no deleterious effect on the mechanical properties of the tendons or bones.(11,20) Preparation and testing were performed at room temperature, and the specimens were kept moist with saline spray throughout the study.”
Vuori, I., Heinonen, A., Siev�nen, H., Kannus, P., Pasanen, M., & Oja, P. (1994) · Calcified Tissue International · doi:10.1007/bf00310170 · Cited by 207
Self-citationHamstring tendon fixation using interference screws: a biomechanical study in calf tibial bone
Weiler, A., Hoffmann, R., Stähelin, A., Bail, H., Siepe, C., & Südkamp, N. (1998) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1016/s0749-8063(98)70117-3 · Cited by 201 · cited 4×
“screws provide a better strength of fixation than their metal counterparts.(19) In our study, despite an apparent”
InfluentialSchatzmann, L., Brunner, P., & Stäubli, H. U. (1998) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/s001670050224 · Cited by 185 · cited 1×
“This cyclic loading-induced increase in the stiffness of ACL reconstruction is likely attributable to the altered viscoelastic properties (diminished creep) of the tendon graft, as has been demonstrated earlier with human patellar and quadriceps tendons.(12) Because of the improvements in certain implant groups, recom…”
Cyclic Pull-Out Strength of Hamstring Tendon Graft Fixation with Soft Tissue Interference Screws
Stadelmaier, D. M., Lowe, W. R., Ilahi, O. A., et al. (1999) · The American Journal of Sports Medicine · doi:10.1177/03635465990270061501 · Cited by 79 · cited 1×
“However, there is controversy over the effects of screw length on graft fixation strength.(13,16,19) The objective of this second part of our study was to evaluate the strength of fixation of six different devices in the fixation of quadrupled hamstring tendon graft to the tibia by using both single-cycle load-to-fail…”
Nurmi, J. T., Järvinen, T. L. N., Kannus, P., Sievänen, H. T., Toukosalo, J., & Järvinen, M. (2002) · The American Journal of Sports Medicine · doi:10.1177/03635465020300020401 · Cited by 64
Self-citationSimonian, P. T., Sussmann, P. S., Baldini, T. H., Crockett, H. C., & Wickiewicz, T. L. (1998) · Arthroscopy The Journal of Arthroscopic and Related Surgery · doi:10.1016/s0749-8063(98)70072-6 · Cited by 50
Kousa, P., Järvinen, T. L. N., Kannus, P., Ahvenjärvi, P., Kaikkonen, A., & Järvinen, M. (2001) · Arthroscopy The Journal of Arthroscopic and Related Surgery · doi:10.1053/jars.2001.20097 · Cited by 21
Self-citation
Cited by
Pinczewski, L. A., Lyman, J., Salmon, L. J., Russell, V. J., Roe, J., & Linklater, J. (2007) · The American Journal of Sports Medicine · doi:10.1177/0363546506296042 · Cited by 661
Aglietti, P., Giron, F., Buzzi, R., Biddau, F., & Sasso, F. (2004) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-200410000-00004 · Cited by 386
LIM, J., HUI, J., LI, L., THAMBYAH, A., GOH, J., & LEE, E. (2004) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1016/j.arthro.2004.06.035 · Cited by 312
Järvelä, T. (2007) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/s00167-006-0254-z · Cited by 312
Causes for failure of ACL reconstruction and influence of meniscectomies after revision
Trojani, C., Sbihi, A., Djian, P., Potel, J., Hulet, C., Jouve, F., Bussière, C., Ehkirch, F., Burdin, G., Dubrana, F., et al. (2011) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/s00167-010-1201-6 · Cited by 249
Metadata
- Authors
- Kousa, P., Järvinen, T. L. N., Vihavainen, M., Kannus, P., & Järvinen, M.
- Venue
- The American Journal of Sports Medicine
- Publisher
- SAGE Publications
- Published
- 2003-03
- Volume
- 31
- Issue
- 2
- Pages
- 182-188
- ISSN
- 0363-5465 (ISSN-L)
- 1552-3365
- OpenAlex
- W4229511794
- Cited by
- 247
- References
- 12
- FWCI
- 11.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.