Influence of the Femoral Tunnel Location and Angle on the Contact Pressure in the Femoral Tunnel in Anterior Cruciate Ligament Reconstruction
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
Background: The causes of bone tunnel enlargement after anterior cruciate ligament reconstruction have not been thoroughly investigated. Hypothesis: A malpositioned femoral tunnel and an acute femoral tunnel angle may increase the mechanical stress in the femoral tunnel. Study Design: Controlled laboratory study. Methods: Three femoral tunnels (normal, anterior, and acute) and the tibial tunnel were made in four fresh-frozen cadaveric knees. Aluminum cylinders containing pressure-sensitive conductive rubber sensors at the joint entrance were inserted into the femoral tunnels. Dynamic changes in the contact pressure of the graft in the femoral tunnel were measured. Results: Peak contact pressures and dynamic changes in contact pressure for the normal and anterior femoral tunnels demonstrated no differences. Maximum contact pressure of the graft was observed at the anterior portion with the knee in full extension and at the posterior portion with deep knee flexion. Consistent contact pressure occurred at the anterior aspect of the acute femoral tunnel throughout the range of motion. Mean contact pressure at the anterior region of the acute femoral tunnel was significantly higher than that of the normal femoral tunnel at 60°, 90°, and 120° of knee flexion. Conclusions: The consistent contact pressure in the anterior aspect of the acute femoral tunnel may erode the anterior portion of the femoral tunnel, resulting in bone tunnel enlargement. Clinical Relevance: The femoral tunnel direction in anterior cruciate ligament reconstruction is an important factor in reducing femoral tunnel enlargement.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Tendon-healing in a bone tunnel. A biomechanical and histological study in the dog.
Rodeo, S. A., Arnoczky, S. P., Torzilli, P. A., Hidaka, C., & Warren, R. F. (1993) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199312000-00009 · Cited by 1,104 · cited 1×
“Our clinical investigation has shown that the main factors associated with tunnel enlargement are tunnel location and angle.(13) Windshield-wiper motion of the graft, in which the graft swings in a manner similar to a pendulum, with the center of the anchoring point of the graft inside the femoral tunnel, may be exagg…”
BackgroundL’Insalata, J. C., Klatt, B., Fu, F. H., & Harner, C. D. (1997) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/s001670050056 · Cited by 432 · cited 1×
“Bone tunnel enlargement after ACL reconstruction has been reported.(1,2,5,9,10,12) Such enlargement may subsequently compromise revision surgery.”
BackgroundClatworthy, M. G., Annear, P., Bulow, J. ‐., & Bartlett, R. J. (1999) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/s001670050138 · Cited by 415 · cited 1×
“Bone tunnel enlargement after ACL reconstruction has been reported.(1,2,5,9,10,12) Such enlargement may subsequently compromise revision surgery.”
BackgroundJackson, D. W., Windler, G. E., & Simon, T. M. (1990) · The American Journal of Sports Medicine · doi:10.1177/036354659001800101 · Cited by 387
Bone tunnel enlargement after anterior cruciate ligament reconstruction: fact or fiction?
Höher, J., Möller, H. D., & Fu, F. H. (1998) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/s001670050105 · Cited by 381 · cited 1×
“Bone tunnel enlargement after ACL reconstruction has been reported.(1,2,5,9,10,12) Such enlargement may subsequently compromise revision surgery.”
BackgroundBone Tunnel Enlargement After Anterior Cruciate Ligament Replacement
Fahey, M., & Indelicato, P. A. (1994) · The American Journal of Sports Medicine · doi:10.1177/036354659402200318 · Cited by 274 · cited 2×
“Bone tunnel enlargement after ACL reconstruction has been reported.(1,2,5,9,10,12) Such enlargement may subsequently compromise revision surgery.”
BackgroundNebelung, W. (1998) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1016/s0749-8063(98)70015-5 · Cited by 234
Jansson, K. A., Harilainen, A., Sandelin, J., Karjalainen, P. T., Aronen, H. J., & Tallroth, K. (1999) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/s001670050166 · Cited by 196
Höher, J., Livesay, G. A., Ma, C. B., Withrow, J. D., Fu, F. H., & Woo, S. L. (1999) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/s001670050151 · Cited by 194 · cited 1×
“Graft stiffness will decrease with increasing graft length.(4) However, differences were not observed between the mean contact pressure of the anterior portion of the normal femoral tunnel and that of the acute femoral tunnel with full knee extension.”
BackgroundPeyrache, M. D., Djian, P., Christel, P., & Witvoet, J. (1996) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/bf01565989 · Cited by 192 · cited 2×
“Bone tunnel enlargement after ACL reconstruction has been reported.(1,2,5,9,10,12) Such enlargement may subsequently compromise revision surgery.”
Background
Cited by
Purnell, M. L., Larson, A. I., & Clancy, W. (2008) · The American Journal of Sports Medicine · doi:10.1177/0363546508319896 · Cited by 261
Rodeo, S. A., Kawamura, S., Kim, H.-J., Dynybil, C., & Ying, L. (2006) · The American Journal of Sports Medicine · doi:10.1177/0363546506290059 · Cited by 238
“Our results are also supported by a recent cadaveric study that used pressure sensors to measure contact pressure between a tendon graft and the bone tunnel.(23) These authors found that contact pressures were highest in the posterior part of the tendonbone interface with the knee in flexion.”
ResultGraft healing in anterior cruciate ligament reconstruction
Ekdahl, M., Wang, J. H. ‐., Ronga, M., & Fu, F. H. (2008) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/s00167-008-0584-0 · Cited by 233
Dargel, J., Schmidt‐Wiethoff, R., Fischer, S., Mader, K., Koebke, J., & Schneider, T. (2009) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/s00167-008-0639-2 · Cited by 188
“rior aspect of the graft with full extension of the knee and may cause bone tunnel enlargement [29].”
BackgroundBasdekis, G., Abisafi, C., & Christel, P. (2008) · Arthroscopy The Journal of Arthroscopic and Related Surgery · doi:10.1016/j.arthro.2007.10.012 · Cited by 126
Gavriilidis, I., Motsis, E., Pakos, E. E., Georgoulis, A. D., Mitsionis, G. I., & Xenakis, T. A. (2008) · The Knee · doi:10.1016/j.knee.2008.05.004 · Cited by 113
“The problem with AM portal is the limited visibility and also the excessive angulation of the tunnel in the sagittal plane [35] which may erode the anterior portion of the knee resulting in bone tunnel enlargement [36].”
BackgroundFemoral attachment of the anterior cruciate ligament
Giron, F., Cuomo, P., Aglietti, P., Bull, A. M. J., & Amis, A. A. (2005) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1007/s00167-005-0685-y · Cited by 109
“However, based on a recent laboratory study [36], a disadvantage of this technique seems to be the excessive angulation of the tunnel in the sagittal plane.”
BackgroundIriuchishima, T., Tajima, G., Ingham, S. J. M., Shen, W., Smolinski, P. J., & Fu, F. H. (2010) · The American Journal of Sports Medicine · doi:10.1177/0363546510363461 · Cited by 92
Tudisco, C., & Bisicchia, S. (2012) · Orthopedics · doi:10.3928/01477447-20120725-14 · Cited by 54
Robert, H. E., Bouguennec, N., Vogeli, D., Berton, E., & Bowen, M. K. (2013) · The American Journal of Sports Medicine · doi:10.1177/0363546513498989 · Cited by 50
“This situation may erode the anterior portion of the femoral tunnel, resulting in tunnel enlargement.(37) Basdekis et al(3) concluded that tunnels should be drilled at 110 of flexion to obtain an obliquity of the tunnel of 32 (b angle) and an average intraosseous tunnel length of 40 mm.”
BackgroundΒasdekis, G., Abisafi, C., & Christel, P. (2009) · Arthroscopy The Journal of Arthroscopic and Related Surgery · doi:10.1016/j.arthro.2009.05.018 · Cited by 50
Morphological Changes in Femoral Tunnels after Anatomic Anterior Cruciate Ligament Reconstruction
Tachibana, Y., Mae, T., Shino, K., Kanamoto, T., Sugamoto, K., Yoshikawa, H., & Nakata, K. (2015) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1007/s00167-014-3252-6 · Cited by 49
“[37] measured the contact pressure of the graft in the femoral tunnel using pressure-sensitive conductive sensors after ACL reconstruction and concluded that a high contact pressure was observed in the anterior portion at 0° and 30° of knee flexion.”
BackgroundMethodInfluentialAu, A. G., Raso, V. J., Liggins, A. B., Otto, D. D., & Amirfazli, A. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.05.007 · Cited by 40
Yanagisawa, S., Kimura, M., 萩原, 敬., Ogoshi, A., Nakagawa, T., Shiozawa, H., Ohsawa, T., & Chikuda, H. (2017) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1007/s00167-017-4679-3 · Cited by 32
“Mechanical causes considered to affect tunnel enlargement include non-anatomic tunnel placement [22, 37, 38], micromotion at the tunnel aperture when soft tissue grafts are used with suspensory fixation [7, 51], increased stress at the tunnel-graft interface [39], and aggressive rehabilitation [48].”
BackgroundAmano, H., Tanaka, Y., Kita, K., Uchida, R., Tachibana, Y., Yonetani, Y., Mae, T., Shiozaki, Y., & Horibe, S. (2018) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1007/s00167-018-5098-9 · Cited by 28
Hoshino, Y. Y., Kuroda, R., Nishizawa, Y., Nakano, N., Nagai, K., Araki, D., Oka, S., Kawaguchi, S., Nagamune, K., & Kurosaka, M. (2017) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1007/s00167-017-4543-5 · Cited by 28
Masuda, T., Kondo, E., Onodera, J., Kitamura, N., Inoue, M., Nakamura, E., Yagi, T., Iwasaki, N., & Yasuda, K. (2018) · Orthopaedic Journal of Sports Medicine · doi:10.1177/2325967118811293 · Cited by 28
Azzam, M. G., Lenarz, C. J., Farrow, L. D., Israel, H. A., Kieffer, D. A., & Kaar, S. G. (2011) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1007/s00167-010-1389-5 · Cited by 30
“anatomic placement of the ACL graft in its native footprint has a favorable impact on knee kinematics [2, 29, 35, 44, 46].”
BackgroundNiki, Y., Nagai, K., Harato, K., Suda, Y., Nakamura, M., & Matsumoto, M. (2015) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1007/s00167-015-3761-y · Cited by 26
“One can easily imagine that an acute GBA would concentrate stress at the edge of the tunnel aperture, resulting in tunnel enlargement and graft rupture according to the past in vitro studies [6, 19].”
BackgroundSegawa, H., Koga, Y., Omori, G., Sakamoto, M., & Hara, T. J. (2005) · Arthroscopy The Journal of Arthroscopic and Related Surgery · doi:10.1016/j.arthro.2004.12.007 · Cited by 25
Self-citationDhaher, Y. Y., Salehghaffari, S., & Adouni, M. (2016) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2016.07.019 · Cited by 22
The cross‐sectional shape of the fourfold semitendinosus tendon is oval, not round
Oshima, T., Nakase, J., Numata, H., Takata, Y., & Tsuchiya, H. (2016) · Journal of Experimental Orthopaedics · doi:10.1186/s40634-016-0063-3 · Cited by 21
“In the round femoral tunnel, Segawa et al. (Segawa et al. 2003) evaluated dynamic changes of the graft in the femoral round tunnel using a pressure sensor and demonstrated maximum contact pressure of the graft at the anterior portion of the femoral tunnel when the knee was in full extension.”
MethodCheng, R., Wang, H., Jiang, Z., Dimitriou, D., Cheng, C.-K., & Tsai, T.-Y. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.797389 · Cited by 20
Evaluation of the semitendinosus tendon graft shift in the bone tunnel: an experimental study
Fujii, M., Sasaki, Y., Araki, D., Furumatsu, T., Miyazawa, S., Ozaki, T., Linde-Rosen, M., Smolinski, P. J., & Fu, F. H. (2014) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1007/s00167-014-3461-z · Cited by 22
“[18] performed an experimental study that evaluated the dynamic change in contact pressure of the graft in the femoral tunnel.”
BackgroundMethodInfluentialAdouni, M., Faisal, T. R., & Dhaher, Y. Y. (2021) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2021.2006647 · Cited by 18
“This high compressive stress represents a limitation that explains the higher calculated graft force within the surgical design during this investigation and earlier published studies (Segawa et al. 2003; Salehghaffari and Dhaher 2015; Dhaher et al. 2016).”
ResultKim, S., Kim, S., Choi, C., Kim, D.-H., & Jung, M. (2018) · BioMed Research International · doi:10.1155/2018/2643247 · Cited by 18
“According to a previous study [32], consistent contact pressure occurred at the anterior aspect of the tunnel and anterior portion of the graft had maximum contact pressure with the knee in full extension.”
Wang, R., Xu, B., Wu, L., & Hong-gang, X. (2017) · Journal of International Medical Research · doi:10.1177/0300060517722243 · Cited by 15
“This has been attributed to the “killer turn” formed when preparing the tibial tunnel,(10) in which the tendon graft forms an acute angle and scratches the sub-tibial cortical bone.(11) The friction can lead to tendon graft injury and affect the creeping substitution by bone marrow mesenchymal cells and fibroblasts.”
BackgroundLee, D. K., Kim, J., Lee, S., Lee, B. H., Kim, H., Kim, J., & Wang, J. H. (2021) · Arthroscopy The Journal of Arthroscopic and Related Surgery · doi:10.1016/j.arthro.2021.03.008 · Cited by 15
Experimental and Numerical Analysis of Screw Fixation in Anterior Cruciate Ligament Reconstruction
Chizari, M., Wang, B., Snow, M., Barrett, M., & Korsunsky, A. M. (2008) · AIP conference proceedings · doi:10.1063/1.2991351 · Cited by 15
“These stress changes can lead to post-operative tunnel enlargement possibly due to bone stress deprivation around the tunnels [2], resulting in graft failure and subsequent revision ACL surgery [3].”
BackgroundOhori, T., Mae, T., Shino, K., Tachibana, Y., Sugamoto, K., Yoshikawa, H., & Nakata, K. (2017) · Journal of Experimental Orthopaedics · doi:10.1186/s40634-017-0104-6 · Cited by 14
“Thus, excessive tension of the graft (Jagodzinski et al., 2005; Segawa et al., 2003), nonanatomical tunnel placement (Segawa et al., 2001; Xu et al., 2011), and aggressive rehabilitation (Hantes et al., 2004; Vadalà et al., 2007) are associated with the phenomenon.”
BackgroundKim, S., Chun, Y., Kim, S., Moon, H.-K., & Jang, J. (2013) · Yonsei Medical Journal · doi:10.3349/ymj.2013.54.4.1006 · Cited by 11
Yanagisawa, S., Kimura, M., 萩原, 敬., Ogoshi, A., Nakagawa, T., Shiozawa, H., & Ohsawa, T. (2017) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1007/s00167-017-4611-x · Cited by 12
“Mechanical causes may include nonanatomic tunnel placement [13, 17, 18], micromotion at the tunnel aperture when soft tissue grafts are used with suspensory fixation [5, 29], increased stress at the tunnel–graft interface [19], or aggressive rehabilitation Table 1 Patient demographics and preoperative and post-operati…”
BackgroundColombet, P. D., Silvestre, A., & Bouguennec, N. (2018) · Journal of Experimental Orthopaedics · doi:10.1186/s40634-018-0125-9 · Cited by 11
“Given its direction, the graft does not fill up the whole tunnel aperture but occupies the anterior part of it (Segawa et al., 2003).”
BackgroundMutsuzaki, H., Kinugasa, T., Ikeda, K., & Sakane, M. (2019) · Orthopaedics & Traumatology Surgery & Research · doi:10.1016/j.otsr.2019.01.005 · Cited by 11
Moon, H., Song, S. Y., Oh, J. U., & Seo, Y. (2022) · BMC Musculoskeletal Disorders · doi:10.1186/s12891-022-05713-y · Cited by 10
“They monitored maximum contact pressure at the anterior part of the tunnel with the knee in full extension and at the posterior portion with deep knee flexion [19], which is partly in agreement with our results.”
BackgroundResultInfluentialGermann, M., Snedeker, J. G., Stalder, M., Nuss, K. M. R., Meyer, D. C., & Farshad, M. (2018) · The Knee · doi:10.1016/j.knee.2018.07.010 · Cited by 9
Adouni, M., Faisal, T. R., & Dhaher, Y. Y. (2021) · The Journal of Knee Surgery · doi:10.1055/s-0041-1733879 · Cited by 8
Cheng, R., Wang, H., Dimitriou, D., Jiang, Z., Cheng, C., & Tsai, T. (2022) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.3590 · Cited by 8
“Several studies showed the femoral tunnel placement could affect femoral tunnel enlargement.10,30 Segawa et al.30 reported that a more proximal femoral tunnel might increase the mechanical stress on the femoral tunnel entrance, thus resulting in greater bone tunnel enlargement.”
BackgroundInfluentialChoi, C., Kim, S., Chun, Y., Kim, S., Lee, S.-K., Eom, N. K., & Jung, M. (2017) · The Knee · doi:10.1016/j.knee.2017.09.005 · Cited by 8
Influence of the bone block position on the tunnel enlargement in ACL reconstruction
Hoigne, D. J., & Ballmer, P. M. (2010) · Orthopedic Reviews · doi:10.4081/or.2010.e12 · Cited by 6
Chung, K., Choi, C., Kim, S., Kim, S., Choi, H. C., & Jung, M. (2023) · Scientific Reports · doi:10.1038/s41598-023-41002-x · Cited by 5
“4): Graft bending angle (θ) to previous studies 27,28 , stress at the tunnel aperture-graft interface is maximized with the knee in near-full extension.”
MethodExperimental and numerical analysis of screw fixation in anterior cruciate ligament reconstruction.
Chizari, M., Wang, B., & Snow, M. (2007) · Cited by 5
Onodera, J., Yasuda, K., Masuda, T., Tanabe, Y., Kitamura, N., Yagi, T., & Kondo, E. (2017) · Orthopaedic Journal of Sports Medicine · doi:10.1177/2325967117711120 · Cited by 5
“tendon is shifted anteriorly in the bone tunnel immediately after surgery with this fixation method, contacting with the anterior wall of the tunnel outlet.(7,23,26,33) Therefore, it has been a common belief in the clinical field that the grafted tendon may shift anteriorly in the femoral tunnel permanently after the…”
MethodKimura, M., Nakase, J., Asai, K., Yoshimizu, R., Kanayama, T., & Tsuchiya, H. (2022) · Asia-Pacific Journal of Sports Medicine Arthroscopy Rehabilitation and Technology · doi:10.1016/j.asmart.2022.03.003 · Cited by 7
Anatomic double‐bundle ACL reconstruction with femoral cortical bone bridge support using hamstrings
Özer, H., Selek, H. Y., & Turanlı, S. (2009) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1007/s00167-009-0840-y · Cited by 3
“Mechanical failure may exist with a femoral tunnel placed acutely [9].”
BackgroundMastrokalos, D. S., Roustemis, A. G., & Koulalis, D. (2025) · SICOT-J · doi:10.1051/sicotj/2025002 · Cited by 2
EVALUATING THE ACCURACY OF KNEE KINEMATICS MEASURED IN SIX DEGREES OF FREEDOM USING SURFACE MARKERS
Fisk, J. A. (2004) · D-Scholarship@Pitt (University of Pittsburgh) · Cited by 3
Sasaki, R., Niki, Y., Kaneda, K., Yamada, Y., Harato, K., Kobayashi, S., Nagura, T., Nakamura, M., & Jinzaki, M. (2025) · The Knee · doi:10.1016/j.knee.2025.11.003 · Cited by 1
Establishment of Anterior Cruciate Ligament Reconstruction Model in Rabbit
Wen, C.-Y., & Chan, K.-M. (2008) · WORLD SCIENTIFIC eBooks · doi:10.1142/9789812794093_0031 · Cited by 1
Bone Tunnel Changes After ACL Reconstruction
Araki, D., Matsushita, T., & Kuroda, R. (2016) · Springer eBooks · doi:10.1007/978-4-431-55858-3_21 · Cited by 1
Liu, Y., Deng, X., Havasy, J., Green, S., Piacentini, A. N., Chen, D., & Rodeo, S. A. (2023) · Journal of Orthopaedic Research® · doi:10.1002/jor.25520 · Cited by 2
Bombacı, H., CETINKAYA, F., Akıncı, O., & KILICOGLU, G. (2021) · Acta chirurgiae orthopaedicae et traumatologiae Cechoslovaca · doi:10.55095/achot2021/064 · Cited by 1
Effect of femoral tunnel angle on tunnel enlargement in anterior cruciate ligament reconstructions
Shen, G., Xu, Y.-J., Zhou, H.-B., Niu, W., Guo, X., Yin, M. Z., & Ding, Z.-Q. (2008) · Springer eBooks · doi:10.1007/978-3-540-79039-6_28
Cheli, A. F., Soldati, F., Buda, M., & Osti, L. (2016) · LO SCALPELLO-OTODI Educational · doi:10.1007/s11639-016-0168-6
“allargamento del tunnel e/o fallimento precoce del graft [43, 44].”
BackgroundBiomechnical senstivity of the knee joint after ACL-reconstruction surgery
Dhaher, Y. Y., Salehghaffari, S., & Adouni, M. (2016) · Cairo International Biomedical Engineering Conference · doi:10.1109/cibec.2016.7836115
Kinematics of the Anterior Cruciate Ligament (ACL) and ACL Graft
Zhu, J. (2018) · D-Scholarship@Pitt (University of Pittsburgh) · Cited by 1
Weiss, D. L., Tomlinson, E. L., Law, C. K., Obana, K. K., Piasecki, D. P., Saltzman, B. M., & Trofa, D. P. (2026) · JAAOS Global Research and Reviews · doi:10.5435/jaaosglobal-d-25-00470
Metadata
- Authors
- Segawa, H., Koga, Y., Omori, G., Sakamoto, M., & Hara, T.
- Affiliations
- Niigata Cancer Center Hospital (JP)
- Department of Orthopaedic Surgery, Niigata Kobari Hospital, Niigata City, Japan
- Niigata University (JP)
- Venue
- The American Journal of Sports Medicine
- Publisher
- SAGE Publications
- Published
- 2003-03
- Volume
- 31
- Issue
- 3
- Pages
- 444-448
- ISSN
- 0363-5465 (ISSN-L)
- 1552-3365
- OpenAlex
- W2100080228
- Cited by
- 57
- References
- 14
- Citations by year
- 2026: 1 · 2025: 2 · 2023: 2 · 2022: 3 · 2021: 5 · 2019: 1 · 2018: 6 · 2017: 7 · 2016: 5 · 2015: 1 · 2014: 2 · 2013: 2 · 2012: 1
- FWCI
- 1.69
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- The American Journal of Sports Medicine (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Smith and Nephew
- Topics
- Health Sciences › Medicine › Surgery › Knee injuries and reconstruction techniques
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Foot and Ankle Surgery
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Tendon Structure and Treatment
- Keywords
- anterior cruciate ligament reconstruction, contact pressure, bone tunnel enlargement, knee flexion
- MeSH terms
- Biomechanical Phenomena, Cadaver, Femur, Humans, Knee Joint, Pressure, Stress, Mechanical, Tibia, Anterior Cruciate Ligament, Statistics, Nonparametric
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.