The DOI matches its Crossref record.
In Vivo Articular Cartilage Contact Kinematics of the Knee: An Investigation Using Dual-Orthogonal Fluoroscopy and Magnetic Resonance Image–Based Computer Models
Abstract
Background: Quantifying the in vivo cartilage contact mechanics of the knee may improve our understanding of the mechanisms of joint degeneration and may therefore improve the surgical repair of the joint after injury. Objective: To measure tibiofemoral articular cartilage contact kinematics during in vivo knee flexion. Study Design: Descriptive laboratory study. Methods: Orthogonal fluoroscopic images and magnetic resonance image–based computer models were used to measure the motion of the cartilage contact points during a quasi-static lunge in 5 human subjects. Results: On the tibial plateau, the contact point moved in both the anteroposterior and the mediolateral directions during knee flexion. On the medial tibial plateau, flexion angle did not have a statistically significant effect on the location of the contact points. The total translation of the contact point from full extension to 90° of flexion was less than 1.5 mm in the anteroposterior direction, whereas the translation in the mediolateral direction was more than 5.0 mm. In the anteroposterior direction, the contact points were centered on the medial tibial plateau. On the lateral tibial plateau, there was a statistically significant difference between the location of the contact point at full extension and the locations of the contact points at other flexion angles in the anteroposterior direction. No significant difference was detected between the location of the contact points at other flexion angles. The overall range of contact point motion was about 9.0 mm in the anteroposterior direction and about 4.0 mm in the mediolateral direction. The contact points were primarily on the inner half of the medial and lateral tibial plateaus (the half closest to the tibial spine). The contact points on both femoral condyles were also on the inner half of the condyles (near the condylar notch). Conclusions: The tibiofemoral contact points move in 3 dimensions during weightbearing knee flexion. The medial tibiofemoral contact points remained within the central portion of the tibial plateau in the anteroposterior direction. Both the medial and lateral tibiofemoral contact points were located on the inner portions of the tibial plateau and femoral condyles (close to the tibial spine), indicating that the tibial spine may play an important role in knee stability. Clinical Relevance: The results of this study may provide important insight as to the mechanisms contributing to the development of osteoarthritis after ligament injuries.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Treatment of Anterior Cruciate Ligament Injuries, Part I
Beynnon, B. D., Johnson, R. J., Abate, J. A., Fleming, B. C., & Nichols, C. E. (2005) · The American Journal of Sports Medicine · doi:10.1177/0363546505279913 · Cited by 638
The role of ambulatory mechanics in the initiation and progression of knee osteoarthritis
Andriacchi, T. P., & Mündermann, A. (2006) · Current Opinion in Rheumatology · doi:10.1097/01.bor.0000240365.16842.4e · Cited by 627
Gait analysis methods in rehabilitation
Baker, R. (2006) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-3-4 · Cited by 587
Brainerd, E. L., Baier, D. B., Gatesy, S. M., Hedrick, T. L., Metzger, K. A., Gilbert, S. L., & Crisco, J. J. (2010) · Journal of Experimental Zoology Part A: Ecological Genetics and Physiology · doi:10.1002/jez.589 · Cited by 524
DeFrate, L. E., Papannagari, R., Gill, T. J., Moses, J. M., Pathare, N. P., & Li, G. (2006) · The American Journal of Sports Medicine · doi:10.1177/0363546506287299 · Cited by 272
Self-citation
Metadata
- Authors
- Li, G., DeFrate, L. E., Park, S. E., Gill, T. J., & Rubash, H. E.
- Venue
- The American Journal of Sports Medicine
- Publisher
- SAGE Publications
- Published
- 2005-01
- Volume
- 33
- Issue
- 1
- Pages
- 102-107
- ISSN
- 0363-5465 (ISSN-L)
- 1552-3365
- OpenAlex
- W2041508016
- Cited by
- 171
- References
- 0
- FWCI
- 6.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: In Vivo Articular Cartilage Contact Kinematics of the Knee: An Investigation Using Dual-Orthogonal Fluoroscopy and Magnetic Resonance Image–Based Computer Models. https://app.cochat.ai/papers/10.1177/0363546504265577
- The paper
- Li, G., DeFrate, L. E., Park, S. E., Gill, T. J., & Rubash, H. E. (2005). In Vivo Articular Cartilage Contact Kinematics of the Knee: An Investigation Using Dual-Orthogonal Fluoroscopy and Magnetic Resonance Image–Based Computer Models. The American Journal of Sports Medicine. https://doi.org/10.1177/0363546504265577
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.