The DOI matches its Crossref record.
Weakness in End-Range Plantar Flexion after Achilles Tendon Repair
Abstract
Background: Separation of tendon ends after Achilles tendon repair may affect the tendon repair process and lead to postoperative end-range plantarflexion weakness. Hypothesis: Patients will have disproportionate end-range plantarflexion weakness after Achilles tendon repair. Study Design: Descriptive laboratory study. Methods: Four-strand core suture repairs of Achilles tendon were performed on 1 female and 19 male patients. Postoperatively, patients were nonweightbearing with the ankle immobilized for 4 weeks. Plantarflexion torque, dorsiflexion range of motion, passive joint stiffness, toe walking, and standing single-legged heel rise (on an incline, decline, and level surface) were assessed after surgery (mean, 1.8 years postoperative; range, 6 months-9 years). Maximum isometric plantarflexion torque was measured at 20° and 10° of dorsiflexion, neutral, and 10° and 20° of plantar flexion. Percentage strength deficit (relative to noninvolved leg) was computed at each angle. Passive dorsiflexion range of motion was measured goniometrically. Passive joint stiffness was computed from increase in passive torque between 10° and 20° of dorsiflexion, before isometric contractions. Results: Significant plantarflexion weakness was evident on the involved side at 20° and 10° of plantar flexion (34% and 20% deficits, respectively; P < .001), with no torque deficits evident at other angles (6% at neutral, 3% at 10° of dorsiflexion, 0% at 20° of dorsiflexion). Dorsiflexion range of motion was not different between involved and noninvolved sides (P = .7). Passive joint stiffness was 34% lower on the involved side (P < .01). All patients could perform an incline heel rise; 14 patients could not perform a decline heel rise (P < .01). Conclusion: Disproportionate weakness in end-range plantar flexion, decreased passive stiffness in dorsiflexion, and inability to perform a decline heel rise are evident after Achilles tendon repair. Possible causes include anatomical lengthening, increased tendon compliance, and insufficient rehabilitation after Achilles tendon repair. Clinical Relevance: Impairments will have functional implications for activities (eg, descending stairs and landing from a jump). Weakness in end-range plantar flexion may be an unrecognized problem after Achilles tendon repair.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ardern, C. L., Glasgow, P., Schneiders, A., Witvrouw, E., Clarsen, B., Cools, A., Gojanovic, B., Griffin, S., Khan, K. M., Moksnes, H., et al. (2016) · British Journal of Sports Medicine · doi:10.1136/bjsports-2016-096278 · Cited by 985
Nilsson-Helander, K., Grävare Silbernagel, K., Thomeé, R., Faxén, E., Olsson, N., Eriksson, B. I., & Karlsson, J. (2010) · The American Journal of Sports Medicine · doi:10.1177/0363546510376052 · Cited by 420
Arampatzis, A., Karamanidis, K., & Albracht, K. (2007) · Journal of Experimental Biology · doi:10.1242/jeb.003814 · Cited by 354
Schepull, T., Kvist, J., Norrman, H., Trinks, M., Berlin, G., & Aspenberg, P. (2011) · The American Journal of Sports Medicine · doi:10.1177/0363546510383515 · Cited by 264
Metadata
- Authors
- Mullaney, M. J., McHugh, M. P., Tyler, T. F., Nicholas, S. J., & Lee, S. J.
- Venue
- The American Journal of Sports Medicine
- Publisher
- SAGE Publications
- Published
- 2006-07
- Volume
- 34
- Issue
- 7
- Pages
- 1120-1125
- ISSN
- 0363-5465 (ISSN-L)
- 1552-3365
- OpenAlex
- W1991900725
- Cited by
- 162
- References
- 0
- FWCI
- 2.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Weakness in End-Range Plantar Flexion after Achilles Tendon Repair. https://app.cochat.ai/papers/10.1177/0363546505284186
- The paper
- Mullaney, M. J., McHugh, M. P., Tyler, T. F., Nicholas, S. J., & Lee, S. J. (2006). Weakness in End-Range Plantar Flexion after Achilles Tendon Repair. The American Journal of Sports Medicine. https://doi.org/10.1177/0363546505284186
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.