Radiographic Measures of Knee Alignment in Patients with varus Gonarthrosis: Effect of Weightbearing Status and Associations with Dynamic Joint Load
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
Background: Radiographic measures of lower limb malalignment are used to indicate abnormal loading of the knee and to plan corrective procedures. Hypotheses: Weightbearing status during hip-to-ankle radiographs will significantly affect malalignment measures; malalignment in single-limb standing will be most highly correlated to the external knee adduction moment during gait, a proposed dynamic measure of functional knee joint load. Study Design: Controlled laboratory study. Methods: Mechanical axis angle was measured in 40 patients with varus gonarthrosis from hip-to-ankle radiographs taken with patients in single-limb standing, double-limb standing, and supine positions. Kinematic and kinetic data were collected during walking and used to calculate the peak adduction moment about the knee. Results: Repeated-measures analysis of variance and Scheffé post hoc tests indicated that mechanical axis angle measured on single-limb standing radiographs (-8.7°± 4.0°) was significantly greater than on double-limb standing radiographs (-7.1°± 3.8°), which was significantly greater than on supine radiographs (-5.5°± 2.8°). The peak knee adduction moment (2.8 ± 0.8 percentage body weight × height) was only moderately correlated with mechanical axis angle on single-limb standing (r = -0.46), double-limb standing (r = -0.45), and supine (r = -0.43) radiographs. Conclusion: Patient position significantly affects frontal plane knee alignment. However, the peak knee adduction moment is only moderately correlated to mechanical axis angle, regardless of weightbearing status. Clinical Relevance: These findings are inconsistent with the hypothesis that mechanical axis angle measured in single-limb standing is more representative of dynamic joint load and further highlight the differences between static and dynamic measures. Results also underscore the importance of reporting patient position during radiographs and keeping positions consistent when evaluating patients over time.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Radiological Assessment of Osteo-Arthrosis
Kellgren, J. H., & Lawrence, J. S. (1957) · Annals of the Rheumatic Diseases · doi:10.1136/ard.16.4.494 · Cited by 12,422 · cited 1×
“The present findings are consistent with the theory that the extent of weightbearing on an OA knee affects lower extremity static alignment.(12) Specifically, the mean MA increases with increases in weightbearing status.”
ResultHealth Measurement Scales: A Practical Guide to Their Development and Use
Streiner, D. L., Norman, G. R., & Cairney, J. (1989) · Cited by 9,595
Altman, R., Asch, E., Bloch, D., Bole, G., Borenstein, D., Brandt, K., Christy, W., Cooke, T. D., Greenwald, R., Hochberg, M., et al. (1986) · Arthritis & Rheumatism · doi:10.1002/art.1780290816 · Cited by 6,777
Measurement of lower extremity kinematics during level walking
Kadaba, M. P., Ramakrishnan, H. K., & Wootten, M. E. (1990) · Journal of Orthopaedic Research · doi:10.1002/jor.1100080310 · Cited by 3,216 · cited 1×
“0-mm-diameter wand markers) were attached to the skin with double-sided tape using the Helen Hayes configuration.(11) The patients were asked to walk at a selfselected speed (mean, 1.”
MethodMiyazaki, T., Wada, M., Kawahara, H., Sato, M., Baba, H., & Shimada, S. (2002) · Annals of the Rheumatic Diseases · doi:10.1136/ard.61.7.617 · Cited by 1,441 · cited 5×
“9 N/m rather than normalizing to percentage body weight multiplied by height, as in the present study and those conducted by Wada et al(20) and Miyazaki et al.(13) The peak knee adduction moment in the present study was slightly lower than that reported by those authors and could be attributed to other factors that af…”
BackgroundResultInfluentialPrinciples of Deformity Correction
Paley, D. (2002) · Springer eBooks · doi:10.1007/978-3-642-59373-4 · Cited by 828 · cited 4×
“Although the present results suggest that MA is significantly affected by patient positioning, they do not support the hypothesis that single-limb standing best represents dynamic loading conditions during gait.(17) The correlation coefficients (r = –0.”
InfluentialHurwitz, D. E., Ryals, A. B., Case, J. P., Block, J. A., & Andriacchi, T. P. (2002) · Journal of Orthopaedic Research® · doi:10.1016/s0736-0266(01)00081-x · Cited by 639 · cited 3×
“It is generally agreed that the MA of the lower extremity influences the magnitude of the knee adduction moment during gait(2,10,20); however, the strength of the association remains unclear, and a wide range of correlations have been reported.(2,10,13,20,21) Although it has been theorized that MA measured with patien…”
BackgroundResultAndriacchi, T. P. (1994) · Orthopedic Clinics of North America · doi:10.1016/s0030-5898(20)31924-6 · Cited by 528 · cited 1×
“Alternatively, the peak external adduction moment about the knee during walking gait has been proposed as a measure of the dynamic knee joint load.(3) The adduction moment can be considered an inward turning motion of the lower limb (in the frontal plane) that compresses the medial compartment of the knee.”
BackgroundHealth measurement scales. A practical guide to their development and use
King, M. (1992) · Journal of Psychosomatic Research · doi:10.1016/0022-3999(92)90105-b · Cited by 500
Hunt, M. A., Birmingham, T. B., Giffin, J. R., & Jenkyn, T. R. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.07.002 · Cited by 287 · cited 2×
“Similarly, understanding the temporal relationship between the lever arm and the peak adduction moment may also help explain discrepancies reported in the literature when examining the correlation between static alignment measured in full knee extension and peak knee adduction moment.(9) We believe TABLE 2 Summary Sta…”
BackgroundResultSelf-citation
Cited by
Loading of the Knee Joint during Activities of Daily Living Measured In Vivo in Five Subjects
Kutzner, I., Heinlein, B., Graichen, F., Bender, A., Rohlmann, A., Halder, A., Beier, A., & Bergmann, G. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2010.03.046 · Cited by 798
Foroughi, N., Smith, R., & Vanwanseele, B. (2009) · The Knee · doi:10.1016/j.knee.2008.12.007 · Cited by 270
Hunt, M. A., Birmingham, T. B., Bryant, D., Jones, I., Giffin, J. R., Jenkyn, T. R., & Vandervoort, A. A. (2008) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2007.10.017 · Cited by 233
Self-citationSled, E. A., Khoja, L., Deluzio, K. J., Olney, S. J., & Culham, E. G. (2010) · Physical Therapy · doi:10.2522/ptj.20090294 · Cited by 175
Metadata
- Authors
- Specogna, A. V., Birmingham, T. B., Hunt, M. A., Jones, I. C., Jenkyn, T. R., Fowler, P. J., & Giffin, J. R.
- Venue
- The American Journal of Sports Medicine
- Publisher
- SAGE Publications
- Published
- 2007-01
- Volume
- 35
- Issue
- 1
- Pages
- 65-70
- ISSN
- 0363-5465 (ISSN-L)
- 1552-3365
- OpenAlex
- W2002035751
- Cited by
- 167
- References
- 14
- FWCI
- 5.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.