The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Which Method of Rotator Cuff Repair Leads to the Highest Rate of Structural Healing?: A Systematic Review
Abstract
Background: The purpose of rotator cuff repair is to diminish pain and restore function, and this most predictably occurs when the tendon is demonstrated to heal. Recent improvements in repair methods have led to improved biomechanical performance, but this has not yet been demonstrated to result in higher healing rates. The purpose of our study was to determine whether different repair methods resulted in different rates of recurrent tearing after surgery. Hypotheses: We hypothesized that (1) the rotator cuff repair method will not affect retear rate, and (2) the surgical approach will not affect the retear rate for a given repair method. Study Design: Systematic review of the literature. Methods: The literature was systematically searched to find articles reporting imaging study assessment of structural healing rates after rotator cuff repair, with data stratified according to tear size. Retear rates were compared for transosseous (TO), single-row suture anchor (SA), double-row suture anchor (DA), and suture bridge (SB) repair methods, as well as for open (O), miniopen (MO), and arthroscopic (A) approaches. Results: Retear rates were available for 1252 repairs collected from 23 studies. Retear rates were significantly lower for double-row repairs when compared with TO or SA for all tears greater than 1 cm and ranged from 7% for tears less than 1 cm to 41% for tears greater than 5 cm, in comparison with retear rates for single-row techniques (TO and SA) of 17% to 69% for tears less than 1 cm and greater than 5 cm, respectively. There was no significant difference in retear rates between TO and SA repair methods or between arthroscopic and nonarthroscopic approaches for any tear size. Conclusion: Double-row repair methods lead to significantly lower retear rates when compared with single-row methods for tears greater than 1 cm. Surgical approach has no significant effect on retear rate.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Arthroscopic Repair of Full-Thickness Tears of the Supraspinatus: Does the Tendon Really Heal?
Boileau, P. (2005) · The Journal of Bone and Joint Surgery (American) · doi:10.2106/jbjs.d.02035 · Cited by 1,248
Repair Integrity and Functional Outcome After Arthroscopic Double-Row Rotator Cuff Repair
Sugaya, H., Maeda, K., Matsuki, K., et al. (2007) · Journal of Bone and Joint Surgery · doi:10.2106/jbjs.f.00512 · Cited by 859
Repair Integrity and Functional Outcome After Arthroscopic Double-Row Rotator Cuff Repair
Sugaya, H., Maeda, K., Matsuki, K., et al. (2007) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-200705000-00006 · Cited by 620
Cuff integrity after arthroscopic versus open rotator cuff repair: A prospective study
Bishop, J., Klepps, S., Lo, I. K., Bird, J., Gladstone, J. N., & Flatow, E. L. (2006) · Journal of Shoulder and Elbow Surgery · doi:10.1016/j.jse.2005.09.017 · Cited by 578
Functional and Anatomical Results After Rotator Cuff Repair
Gazielly, D. F., Gleyze, P., & Montagnon, C. (1994) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199407000-00009 · Cited by 549
The Clinical and Structural Long-Term Results of Open Repair of Massive Tears of the Rotator Cuff
Zumstein, M. A., Jost, B., Hempel, J., Hodler, J., & Gerber, C. (2008) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/jbjs.g.00677 · Cited by 487
Prediction of Rotator Cuff Repair Results by Magnetic Resonance Imaging
Thomazeau, H., Boukobza, E., Morcet, N., Chaperon, J., & Langlais, F. (1997) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199711000-00027 · Cited by 482
Park, M. C., ElAttrache, N. S., Tibone, J. E., Ahmad, C. S., Jun, B.-J., & Lee, T. Q. (2007) · Journal of Shoulder and Elbow Surgery · doi:10.1016/j.jse.2006.09.010 · Cited by 410
Lafosse, L., Brozska, R., Toussaint, B., et al. (2007) · Journal of Bone and Joint Surgery · doi:10.2106/jbjs.f.00305 · Cited by 394
LEVEL OF EVIDENCE IN ORTHOPAEDIC JOURNALS
OBREMSKEY, W. T., PAPPAS, N., ATTALLAH-WASIF, E., TORNETTA, P., & BHANDARI, M. (2005) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200512000-00006 · Cited by 359
Cited by
Diercks, R., Bron, C., Dorrestijn, O., Meskers, C., Naber, R., de Ruiter, T., Willems, J., Winters, J., & van der Woude, H. J. (2014) · Acta Orthopaedica · doi:10.3109/17453674.2014.920991 · Cited by 397
Hein, J., Reilly, J. M., Chae, J., Maerz, T., & Anderson, K. (2015) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1016/j.arthro.2015.06.004 · Cited by 284
Millett, P. J., Warth, R. J., Dornan, G. J., Lee, J. T., & Spiegl, U. J. (2014) · Journal of Shoulder and Elbow Surgery · doi:10.1016/j.jse.2013.10.006 · Cited by 281
Yin, Z., Chen, X., Zhu, T., Hu, J.-J., Song, H.-X., Shen, W.-L., Jiang, L.-Y., Heng, B. C., Ji, J.-F., & Ouyang, H.-W. (2013) · Acta Biomaterialia · doi:10.1016/j.actbio.2013.07.022 · Cited by 148
Ramot, Y., Nyska, A., Markovitz, E., Dekel, A., Klaiman, G., Zada, M. H., Domb, A. J., & Maronpot, R. R. (2015) · Toxicologic Pathology · doi:10.1177/0192623315600275 · Cited by 55
Metadata
- Authors
- Duquin, T. R., Buyea, C., & Bisson, L. J.
- Venue
- The American Journal of Sports Medicine
- Publisher
- SAGE Publications
- Published
- 2010-04
- Volume
- 38
- Issue
- 4
- Pages
- 835-841
- ISSN
- 0363-5465 (ISSN-L)
- 1552-3365
- OpenAlex
- W2011402505
- Cited by
- 361
- References
- 15
- FWCI
- 27.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.