Size Variability of the Human Anterior Cruciate Ligament Insertion Sites
The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
Background: Current trends in anterior cruciate ligament reconstruction (ACLR) have been toward anatomical reconstruction that restores the normal size and location of the anterior cruciate ligament insertions and its 2 bundles, the posterolateral (PL) and anteromedial (AM) bundles. This has resulted in a more individualized approach to ACLR. Several studies have shown that the size of the anterior cruciate ligament insertion sites is variable; however, these studies are limited by use of relatively small sample sizes and cadaveric specimens. Purpose: This study was undertaken to evaluate the in vivo size variability of the anterior cruciate ligament insertion sites and its AM and PL bundles during arthroscopy in a large series of patients and to correlate these findings with individuals’ physical characteristics (height, weight, and body mass index). Study Design: Cross-sectional study; Level of evidence, 3. Methods: In 137 patients undergoing ACLR during the first 6 months after injury, the femoral and tibial anterior cruciate ligament insertion sites and the 2 bundles were identified, marked with electrocautery, and measured with an arthroscopic ruler. Additionally, physical characteristics of the patients, including self-reported height, weight, and body mass index, were recorded. Results: The tibial anterior cruciate ligament insertion site had a mean length of 17.0 ± 2.0 mm. The tibial AM bundle length was 9.1 ± 1.2 mm and the width was 9.2 ± 1.1 mm. The tibial PL bundle insertion site length averaged 7.4± 1.0 mm and the width averaged 7.0 ± 1.0 mm. The femoral insertion sites had a mean length of 16.5 ± 2.0 mm. The length of the femoral AM bundle insertion site averaged 9.2 ± 1.2 mm and the width averaged 8.9 ± 0.9 mm. The femoral PL bundle insertion site length averaged 7.1 ± 1.1 mm and the width averaged 6.9 ± 1.0 mm. There were significant positive correlations between patient height and weight ( P < .05) with femoral and tibial anterior cruciate ligament insertion site length, tibial PL bundle insertion site length, femoral AM bundle insertion site length, and tibial AM bundle and PL bundle insertion site areas. However, the coefficients of determination values were low (1.0% to 19.4%). Conclusion: There is a large variation in size of the anterior cruciate ligament insertion sites and the AM and PL bundles. Additionally, there are significant but weak correlations between the size of the insertions and height, weight, and body mass index of the individual patient.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Cruciate Ligaments of the Knee Joint: Anatomical. Functional and Experimental Analysis
Girgis, F. G., Marshall, J. L., & MONA JEM, A. R. S. A. (1975) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-197501000-00033 · Cited by 1,485 · cited 1×
“Several studies have shown that the size of the ACL insertion sites is variable.(6,7,10,21,22) However, these studies are limited by their relatively small sample sizes, use of cadaveric specimens, or the presence of osteoarthritic changes in patients undergoing total knee arthroplasty.”
BackgroundFunctional anatomy of the anterior cruciate ligament and a rationale for reconstruction.
Odensten, M., & Gillquist, J. (1985) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198567020-00012 · Cited by 614
Osseous Landmarks of the Femoral Attachment of the Anterior Cruciate Ligament: An Anatomic Study
Ferretti, M., Ekdahl, M., Shen, W., & Fu, F. H. (2007) · Arthroscopy · doi:10.1016/j.arthro.2007.09.008 · Cited by 540 · cited 2×
“Under arthroscopic visualization, both bundles of the ACL were carefully identified using the injury pattern of the ACL,(27) soft tissue remnants, and bony landmarks including the lateral intercondylar and lateral bifurcate ridge on the medial wall of the lateral femoral condyle.(8) By tracing the ACL remnants, meticu…”
BackgroundMethodSelf-citationColombet, P., Robinson, J., Christel, P., Franceschi, J.-P., Djian, P., Bellier, G., & Sbihi, A. (2006) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1016/j.arthro.2006.04.102 · Cited by 426
Anderson, A. F., Dome, D. C., Gautam, S., Awh, M. H., & Rennirt, G. W. (2001) · The American Journal of Sports Medicine · doi:10.1177/03635465010290011501 · Cited by 382
Zantop, T., Wellmann, M., Fu, F. H., & Petersen, W. (2008) · The American Journal of Sports Medicine · doi:10.1177/0363546507308361 · Cited by 344
Self-citationStäubli, H. ‐., & Rauschning, W. (1994) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/bf01467915 · Cited by 280
A systematic review of the femoral origin and tibial insertion morphology of the ACL
Kopf, S., Musahl, V., Tashman, S., Szczodry, M., Shen, W., & Fu, F. H. (2009) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/s00167-008-0709-5 · Cited by 268 · cited 1×
“However, these studies are limited by their relatively small sample sizes, use of cadaveric specimens, or the presence of osteoarthritic changes in patients undergoing total knee arthroplasty.(12) Currently, there are no in vivo studies that determined the size of the ACL insertion site and its 2 bundles that have use…”
BackgroundSelf-citationAnatomical Limitations of Transtibial Drilling in Anterior Cruciate Ligament Reconstruction
Heming, J. F., Rand, J., & Steiner, M. E. (2007) · The American Journal of Sports Medicine · doi:10.1177/0363546507304137 · Cited by 266
Purnell, M. L., Larson, A. I., & Clancy, W. (2008) · The American Journal of Sports Medicine · doi:10.1177/0363546508319896 · Cited by 261 · cited 1×
“Soft tissue remnants of the ACL stumps, rupture pattern, and anatomical landmarks such as the lateral bifurcate and intercondylar ridges of the femur (present in 98% of cases) have been shown to be critical components for defining the native ACL anatomy.(8,9,20,26-28) Recent publications have recommended single-bundle…”
Background
Cited by
Anatomic anterior cruciate ligament reconstruction: a changing paradigm
Fu, F. H., van Eck, C. F., Tashman, S., Irrgang, J. J., & Moreland, M. S. (2015) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/s00167-014-3209-9 · Cited by 188
“However, a recent study demonstrated that there is substantial variation in the size and shape of the ACL insertion site [25].”
Self-citationSurgery for anterior cruciate ligament deficiency: a historical perspective
Schindler, O. S. (2012) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/s00167-011-1756-x · Cited by 181
“significant variability [87, 160, 288].”
Sasaki, N., Ishibashi, Y., Tsuda, E., Yamamoto, Y., Maeda, S., Mizukami, H., Toh, S., Yagihashi, S., & Tonosaki, Y. (2012) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1016/j.arthro.2011.12.021 · Cited by 164
Metadata
- Authors
- Kopf, S., Pombo, M. W., Szczodry, M., Irrgang, J. J., & Fu, F. H.
- Venue
- The American Journal of Sports Medicine
- Publisher
- SAGE Publications
- Published
- 2010-09-16
- Volume
- 39
- Issue
- 1
- Pages
- 108-113
- ISSN
- 0363-5465 (ISSN-L)
- 1552-3365
- OpenAlex
- W2110817790
- Cited by
- 169
- References
- 24
- FWCI
- 9.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Size Variability of the Human Anterior Cruciate Ligament Insertion Sites. https://app.cochat.ai/papers/10.1177/0363546510377399
- The paper
- Kopf, S., Pombo, M. W., Szczodry, M., Irrgang, J. J., & Fu, F. H. (2011). Size Variability of the Human Anterior Cruciate Ligament Insertion Sites. The American Journal of Sports Medicine. https://doi.org/10.1177/0363546510377399
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.