CoChat

Size Variability of the Human Anterior Cruciate Ligament Insertion Sites

Kopf, Sebastian, Pombo, Mathew W., Szczodry, Michal, Irrgang, James J., Fu, Freddie H. · 2011 · The American Journal of Sports Medicine
Cited by 169

The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.

Abstract

Background: Current trends in anterior cruciate ligament reconstruction (ACLR) have been toward anatomical reconstruction that restores the normal size and location of the anterior cruciate ligament insertions and its 2 bundles, the posterolateral (PL) and anteromedial (AM) bundles. This has resulted in a more individualized approach to ACLR. Several studies have shown that the size of the anterior cruciate ligament insertion sites is variable; however, these studies are limited by use of relatively small sample sizes and cadaveric specimens. Purpose: This study was undertaken to evaluate the in vivo size variability of the anterior cruciate ligament insertion sites and its AM and PL bundles during arthroscopy in a large series of patients and to correlate these findings with individuals’ physical characteristics (height, weight, and body mass index). Study Design: Cross-sectional study; Level of evidence, 3. Methods: In 137 patients undergoing ACLR during the first 6 months after injury, the femoral and tibial anterior cruciate ligament insertion sites and the 2 bundles were identified, marked with electrocautery, and measured with an arthroscopic ruler. Additionally, physical characteristics of the patients, including self-reported height, weight, and body mass index, were recorded. Results: The tibial anterior cruciate ligament insertion site had a mean length of 17.0 ± 2.0 mm. The tibial AM bundle length was 9.1 ± 1.2 mm and the width was 9.2 ± 1.1 mm. The tibial PL bundle insertion site length averaged 7.4± 1.0 mm and the width averaged 7.0 ± 1.0 mm. The femoral insertion sites had a mean length of 16.5 ± 2.0 mm. The length of the femoral AM bundle insertion site averaged 9.2 ± 1.2 mm and the width averaged 8.9 ± 0.9 mm. The femoral PL bundle insertion site length averaged 7.1 ± 1.1 mm and the width averaged 6.9 ± 1.0 mm. There were significant positive correlations between patient height and weight ( P < .05) with femoral and tibial anterior cruciate ligament insertion site length, tibial PL bundle insertion site length, femoral AM bundle insertion site length, and tibial AM bundle and PL bundle insertion site areas. However, the coefficients of determination values were low (1.0% to 19.4%). Conclusion: There is a large variation in size of the anterior cruciate ligament insertion sites and the AM and PL bundles. Additionally, there are significant but weak correlations between the size of the insertions and height, weight, and body mass index of the individual patient.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/0363546510377399

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 169

Metadata

Authors
Kopf, S., Pombo, M. W., Szczodry, M., Irrgang, J. J., & Fu, F. H.
Venue
The American Journal of Sports Medicine
Published
2010-09-16
Volume
39
Issue
1
Pages
108-113
ISSN
  • 0363-5465 (ISSN-L)
  • 1552-3365
OpenAlex
W2110817790
Cited by
169
References
24
FWCI
9.94
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.