Functional and Structural Outcomes of Single-Row Versus Double-Row Versus Combined Double-Row and Suture-Bridge Repair for Rotator Cuff Tears
The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
Background: Although previous biomechanical research has demonstrated the superiority of the suture-bridge rotator cuff repair over double-row repair from a mechanical point of view, no articles have described the structural and functional outcomes of this type of procedure. Hypothesis: The structural and functional outcomes after arthroscopic rotator cuff repair may be different between the single-row, double-row, and combined double-row and suture-bridge (compression double-row) techniques. Study Design: Cohort study; Level of evidence, 3. Methods: There were 206 shoulders in 201 patients with full-thickness rotator cuff tears that underwent arthroscopic rotator cuff repair. Eleven patients were lost to follow-up. Sixty-five shoulders were repaired using the single-row, 23 shoulders using the double-row, and 107 shoulders using the compression double-row techniques. Clinical outcomes were evaluated at an average of 38.5 months (range, 24-74 months) after rotator cuff repair. Postoperative cuff integrity was determined using Sugaya’s classification of magnetic resonance imaging (MRI). Results: The retear rates after arthroscopic rotator cuff repair were 10.8%, 26.1%, and 4.7%, respectively, for the single-row, double-row, and compression double-row techniques. In the subcategory of large and massive rotator cuff tears, the retear rate in the compression double-row group (3 of 40 shoulders, 7.5%) was significantly less than those in the single-row group (5 of 8 shoulders, 62.5%, P < .001) and the double-row group (5 of 12 shoulders, 41.7%, P < .01). Postoperative clinical outcomes in patients with a retear were significantly lower than those in patients without a retear for all 3 techniques. Conclusion: The additional suture bridges decreased the retear rate for large and massive tears. The combination of the double-row and suture-bridge techniques, which had the lowest rate of postoperative retear, is an effective option for arthroscopic repair of the rotator cuff tendons because the postoperative functional outcome in patients with a retear is inferior to that without retear.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Galatz, L. M., Ball, C. M., Teefey, S. A., Middleton, W. D., & Yamaguchi, K. (2004) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-200402000-00002 · Cited by 2,145 · cited 3×
“The recent literature has shown that the retear rate after open and arthroscopic rotator cuff repair remains remarkably high.(5,9,10,12,15) Although the high rate of repair failures has been attributed to many factors, including the severity of the tear,(13,40) the tendon and bone quality,(28) and muscle atrophy and f…”
A standardized method for the assessment of shoulder function
Richards, R. R., An, K.-N., Bigliani, L. U., Friedman, R. J., Gartsman, G. M., Gristina, A. G., Iannotti, J. P., Mow, V. C., Sidles, J. A., & Zuckerman, J. D. (1994) · Journal of Shoulder and Elbow Surgery · doi:10.1016/s1058-2746(09)80019-0 · Cited by 1,726
Fuchs, B., Weishaupt, D., Zanetti, M., Hodler, J., & Gerber, C. (1999) · Journal of Shoulder and Elbow Surgery · doi:10.1016/s1058-2746(99)90097-6 · Cited by 1,413 · cited 2×
“The reliability of the grading system was reported to be .82 to .93 of k values on MRI.8 Surgical Procedure All procedures were performed with the patient under general anesthesia in the lateral decubitus position.”
Repairs of the rotator cuff. Correlation of functional results with integrity of the cuff.
Harryman, D. T., Mack, L. A., Wang, K. Y., Jackins, S. E., Richardson, M. L., & Matsen, F. A. (1991) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199173070-00004 · Cited by 1,259
Arthroscopic Repair of Full-Thickness Tears of the Supraspinatus: Does the Tendon Really Heal?
Boileau, P. (2005) · The Journal of Bone and Joint Surgery (American) · doi:10.2106/jbjs.d.02035 · Cited by 1,248 · cited 2×
“The recent literature has shown that the retear rate after open and arthroscopic rotator cuff repair remains remarkably high.(5,9,10,12,15) Although the high rate of repair failures has been attributed to many factors, including the severity of the tear,(13,40) the tendon and bone quality,(28) and muscle atrophy and f…”
Repair of the rotator cuff. End-result study of factors influencing reconstruction.
Ellman, H., Hanker, G., & Bayer, M. (1986) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198668080-00002 · Cited by 1,013
Repair Integrity and Functional Outcome After Arthroscopic Double-Row Rotator Cuff Repair
Sugaya, H., Maeda, K., Matsuki, K., et al. (2007) · Journal of Bone and Joint Surgery · doi:10.2106/jbjs.f.00512 · Cited by 859 · cited 4×
“7%), which is consistent with what has been previously reported.(13,40) Therefore, the single-row and conventional double-row techniques may not be sufficiently strong to prevent retear after the repair of large and massive tears.”
InfluentialRepair Integrity and Functional Outcome After Arthroscopic Double-Row Rotator Cuff Repair
Sugaya, H., Maeda, K., Matsuki, K., et al. (2007) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-200705000-00006 · Cited by 620
Cuff integrity after arthroscopic versus open rotator cuff repair: A prospective study
Bishop, J., Klepps, S., Lo, I. K., Bird, J., Gladstone, J. N., & Flatow, E. L. (2006) · Journal of Shoulder and Elbow Surgery · doi:10.1016/j.jse.2005.09.017 · Cited by 578 · cited 1×
“Furthermore, there appears to be no apparent decrease in the retear rate for the double-row technique compared with the single-row technique.(1,4,6,9,13,19,23,27,39) In particular, high percentages of retear after a double-row *Address correspondence to Teruhisa Mihata, MD, PhD, Department of Orthopedic Surgery, Osaka…”
Functional and Anatomical Results After Rotator Cuff Repair
Gazielly, D. F., Gleyze, P., & Montagnon, C. (1994) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199407000-00009 · Cited by 549 · cited 2×
“The recent literature has shown that the retear rate after open and arthroscopic rotator cuff repair remains remarkably high.(5,9,10,12,15) Although the high rate of repair failures has been attributed to many factors, including the severity of the tear,(13,40) the tendon and bone quality,(28) and muscle atrophy and f…”
Cited by
McElvany, M. D., McGoldrick, E., Gee, A. O., Neradilek, M. B., & Matsen, F. A. (2015) · The American Journal of Sports Medicine · doi:10.1177/0363546514529644 · Cited by 485
Hein, J., Reilly, J. M., Chae, J., Maerz, T., & Anderson, K. (2015) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1016/j.arthro.2015.06.004 · Cited by 284
Factors Affecting Rotator Cuff Healing
Mall, N. A., Tanaka, M. J., Choi, L. S., & Paletta, G. A. (2014) · Journal of Bone and Joint Surgery · doi:10.2106/jbjs.m.00583 · Cited by 228
“In a study of large and massive rotator cuff tears, Mihata et al. noted discontinuity of the rotator cuff tendon in 11% of single-row repairs, 26% of double-row repairs, and only 5% when a compression double-row technique was used37.”
BackgroundInfluentialMori, D., Funakoshi, N., & Yamashita, F. (2013) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1016/j.arthro.2013.08.032 · Cited by 190
Kukkonen, J., Joukainen, A., Lehtinen, J., Mattila, K. T., Tuominen, E. K. J., Kauko, T., & Äärimaa, V. (2014) · The Bone & Joint Journal · doi:10.1302/0301-620x.96b1.32168 · Cited by 172
“08* Working 17 (31) 10 (18) 23 (42) Sick leave 5 (9) 1 (2) 1 (2) Retired 32 (58) 42 (74) 30 (55) Data missing 1 (2) 4 (7) 1 (2) Mean (SD) duration of symptoms (mths) 26 (9.”
Metadata
- Authors
- Mihata, T., Watanabe, C., Fukunishi, K., Ohue, M., Tsujimura, T., Fujiwara, K., & Kinoshita, M.
- Venue
- The American Journal of Sports Medicine
- Publisher
- SAGE Publications
- Published
- 2011-07-22
- Volume
- 39
- Issue
- 10
- Pages
- 2091-2098
- ISSN
- 0363-5465 (ISSN-L)
- 1552-3365
- OpenAlex
- W1991967079
- Cited by
- 205
- References
- 22
- FWCI
- 14.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.