Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 2,145

The DOI matches its Crossref record.

The Outcome and Repair Integrity of Completely Arthroscopically Repaired Large and Massive Rotator Cuff Tears

Galatz, Leesa M., Ball, Craig M., Teefey, Sharlene A., Middleton, William D., Yamaguchi, Ken·2004·The Journal of Bone & Joint Surgery

Abstract

BACKGROUND: The impact of a recurrent defect on the outcome after rotator cuff repair has been controversial. The purpose of this study was to evaluate the functional and anatomic results after arthroscopic repair of large and massive rotator cuff tears with use of ultrasound as an imaging modality to determine the postoperative integrity of the repair. METHODS: Eighteen patients who had complete arthroscopic repair of a tear measuring >2 cm in the transverse dimension were evaluated at a minimum of twelve months after surgery and again at two years after surgery. The evaluation consisted of a standardized history and physical examination as well as calculation of the preoperative and postoperative shoulder scores according to the system of the American Shoulder and Elbow Surgeons. The strength of both shoulders was quantitated postoperatively with use of a portable dynamometer. Ultrasound studies were performed with use of an established and validated protocol at a minimum of twelve months after surgery. RESULTS: Recurrent tears were seen in seventeen of the eighteen patients. Despite the absence of healing at twelve months after surgery, thirteen patients had an American Shoulder and Elbow Surgeons score of >/=90 points. Sixteen patients had an improvement in the functional outcome score, which increased from an average of 48.3 to 84.6 points. Sixteen patients had a decrease in pain, and twelve had no pain. Although eight patients had preoperative forward elevation to <95 degrees, all eighteen regained motion above shoulder level and had an average of 152 degrees of elevation. At the second evaluation, a minimum of twenty-four months after surgery, the average score, according to the system of the American Shoulder and Elbow Surgeons, had decreased to 79.9 points; only nine patients had a score of >/=90 points, and six patients had a score of </=79 points. The average forward elevation decreased to 142 degrees. CONCLUSIONS: Arthroscopic repair of large and massive rotator cuff tears led to a high percentage of recurrent defects. The minimum twelve-month evaluation showed excellent pain relief and improvement in the ability to perform activities of daily living despite the high rate of recurrent defects; however, at a minimum follow-up of two years, the results deteriorated with only twelve patients who had an American Shoulder and Elbow Surgeons score of >/=80.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2106/00004623-200402000-00002

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 2,145

Metadata

Authors
Galatz, L. M., Ball, C. M., Teefey, S. A., Middleton, W. D., & Yamaguchi, K.
Venue
The Journal of Bone & Joint Surgery
Published
2004-02
Volume
86
Issue
2
Pages
219-224
ISSN
0021-9355 (ISSN-L)
OpenAlex
W1863138831
Cited by
2,145
References
0
FWCI
43.01
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Outcome and Repair Integrity of Completely Arthroscopically Repaired Large and Massive Rotator Cuff Tears. https://app.cochat.ai/papers/10.2106/00004623-200402000-00002
The paper
Galatz, L. M., Ball, C. M., Teefey, S. A., Middleton, W. D., & Yamaguchi, K. (2004). The Outcome and Repair Integrity of Completely Arthroscopically Repaired Large and Massive Rotator Cuff Tears. The Journal of Bone & Joint Surgery. https://doi.org/10.2106/00004623-200402000-00002

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.