The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
CT and MRI Measurements of Tibial Tubercle–Trochlear Groove Distances Are Not Equivalent in Patients With Patellar Instability
Abstract
Background: Tibial tubercle–trochlear groove distance (TT-TG) is a commonly used measurement for surgical decision making in patients with patellofemoral malalignment and instability. This measurement has historically been performed utilizing axial computed tomography (CT). More recently, magnetic resonance imaging (MRI) has been proposed as an equivalent method, but this has not yet been fully validated. Purpose: To determine the reliability of TT-TG distance measurements on both MRI and CT and to determine whether the measurements are interchangeable with one another. Study Design: Cohort study (diagnosis); Level of evidence, 2. Methods: All patients with patellar instability who underwent both CT and MRI of the knee from 2003 to 2011 were included (n = 59 knees in 54 patients). Two fellowship-trained musculoskeletal radiologists measured the TT-TG distances for each patient by CT and MRI in a randomized, blinded fashion. Interobserver reliability was calculated between radiologists for both imaging modalities, and intermethod reliability was calculated between the 2 imaging modalities. The results are reported using intraclass correlation coefficients (ICCs) and Bland-Altman analysis. Results: The 59 knees had a mean TT-TG distance of 16.9 mm (range, 8.3-25.8 mm) by CT and 14.7 mm (range, 1.5-25.1 mm) by MRI. Interobserver reliability between the radiologists was considered excellent for both CT and MRI (ICC = 0.777 and 0.843, respectively). When comparing CT to MRI, the ICC was considered only fair for each of the raters (0.532 and 0.539). Eleven patients (19%) had a TT-TG distance of ≥20 mm on CT preoperatively and underwent distal realignment by tibial tubercle osteotomy. In this surgical subgroup, the mean TT-TG distance was 22.5 mm (range, 19.8-25.8 mm) by CT and only 18.7 mm (range, 14.4-22.8 mm) by MRI for a mean difference of 3.80 mm ( P < .001). Conclusion: The TT-TG distance can be measured with excellent interrater reliability on both MRI and CT; however, the values derived from these 2 tests may not be interchangeable. This observation should be taken into consideration when MRI is used for surgical planning because MRI may underestimate the TT-TG distance when compared with CT.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Measurement of Observer Agreement for Categorical Data
Landis, J. R., & Koch, G. G. (1977) · Biometrics · doi:10.2307/2529310 · Cited by 81,148
Intraclass correlations: Uses in assessing rater reliability.
Shrout, P. E., & Fleiss, J. L. (1979) · Psychological Bulletin · doi:10.1037/0033-2909.86.2.420 · Cited by 24,532
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1177/096228029900800204 · Cited by 9,619
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1191/096228099673819272 · Cited by 9,619
Factors of patellar instability: An anatomic radiographic study
Dejour, H., Walch, G., Nove‐Josserand, L., & Guier, C. (1994) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/bf01552649 · Cited by 2,041
Epidemiology and Natural History of Acute Patellar Dislocation
Fithian, D. C., Paxton, E. W., Stone, M. L., Silva, P., Davis, D. K., Elias, D. A., & White, L. M. (2004) · The American Journal of Sports Medicine · doi:10.1177/0363546503260788 · Cited by 1,202
The tibial tuberosity–trochlear groove distance; a comparative study between CT and MRI scanning
Schoettle, P. B., Zanetti, M., Seifert, B., Pfirrmann, C. W. A., Fucentese, S. F., & Romero, J. (2006) · The Knee · doi:10.1016/j.knee.2005.06.003 · Cited by 554
Moro‐oka, T., Hamai, S., Miura, H., SHIMOTO, T., HIGAKI, H., Fregly, B. J., Iwamoto, Y., & Banks, S. A. (2007) · Journal of Orthopaedic Research® · doi:10.1002/jor.20355 · Cited by 141
Koëter, S., Horstmann, W., Wagenaar, F. B. M., Huysse, W. C. J., Wymenga, A. B., & Anderson, P. G. (2006) · The Knee · doi:10.1016/j.knee.2006.11.003 · Cited by 64
Wilcox, J. J., Snow, B. J., Aoki, S. K., Hung, M., & Burks, R. T. (2012) · Clinical Orthopaedics and Related Research · doi:10.1007/s11999-012-2269-8 · Cited by 63
Metadata
- Authors
- Camp, C. L., Stuart, M. J., Krych, A. J., Levy, B. A., Bond, J. R., Collins, M. S., & Dahm, D. L.
- Venue
- The American Journal of Sports Medicine
- Publisher
- SAGE Publications
- Published
- 2013-07-15
- Volume
- 41
- Issue
- 8
- Pages
- 1835-1840
- ISSN
- 0363-5465 (ISSN-L)
- 1552-3365
- OpenAlex
- W2105991223
- Cited by
- 256
- References
- 11
- FWCI
- 8.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: CT and MRI Measurements of Tibial Tubercle–Trochlear Groove Distances Are Not Equivalent in Patients With Patellar Instability. https://app.cochat.ai/papers/10.1177/0363546513484895
- The paper
- Camp, C. L., Stuart, M. J., Krych, A. J., Levy, B. A., Bond, J. R., Collins, M. S., & Dahm, D. L. (2013). CT and MRI Measurements of Tibial Tubercle–Trochlear Groove Distances Are Not Equivalent in Patients With Patellar Instability. The American Journal of Sports Medicine. https://doi.org/10.1177/0363546513484895
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.