Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 162

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Comparison of the Cellular Composition and Cytokine-Release Kinetics of Various Platelet-Rich Plasma Preparations

Oh, Joo Han, Kim, Woo, Park, Kyoung Un, Roh, Young Hak · 2015 · The American Journal of Sports Medicine

Abstract

Background: Variations in formulations used to prepare platelet-rich plasmas (PRPs) result in differences in the cellular composition and biomolecular characteristics. Purpose: To evaluate the cellular composition and the cytokine-release kinetics of PRP according to differences in the preparation protocols. Study Design: Controlled laboratory study. Methods: Five preparation procedures were performed for 14 healthy subjects, including 2 manual procedures (single-spin [SS] at 900 g for 5 minutes; double-spin [DS] at 900 g for 5 minutes and then 1500 g for 15 minutes) and 3 methods with commercial kits (Arthrex ACP, Biomet GPS, and Prodizen Prosys). After evaluation of cellular composition, each preparation was divided into 4 aliquots and incubated for 1 hour, 24 hours, 72 hours, and 7 days for the assessment of cytokine release over time. The cytokine-release kinetics were evaluated by assessing platelet-derived growth factor (PDGF), transforming growth factor (TGF), vascular endothelial growth factor (VEGF), fibroblast growth factor (FGF), interleukin-1 (IL-1), and matrix metalloproteinase–9 (MMP-9) concentrations of each aliquot with bead-based sandwich immunoassay. Results: The DS PRP had a higher concentration of platelets and leukocytes than did the SS PRP. Every PRP preparation exhibited an increase in PDGF, TGF, VEGF, and FGF release when compared with whole blood samples. The FGF and TGF release occurred quickly and decreased over time, while the PDGF and VEGF release was constant and sustained over 7 days. The PDGF and VEGF concentrations were higher in the DS PRP than in the SS PRP, whereas the TGF and FGF concentrations were higher in the SS PRP than in the DS PRP. Biomet GPS had the highest VEGF and MMP-9 concentrations but the lowest TGF concentration. Arthrex ACP had the highest FGF concentration but the lowest PDGF concentration. Prodizen Prosys had the highest IL-1 concentration and higher PDGF concentration than Arthrex ACP. Conclusion: The DS method generally led to a higher concentration of platelet relative to the SS method. However, the cytokine content was not necessarily proportional to the cellular composition of the PRPs, as the greater content could be different between the SS or DS method depending on the type of cytokine. Clinical Relevance: Physicians should select proper PRP preparations after considering their biomolecular characteristics and patient indications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/0363546515608481

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 162

Metadata

Authors
Oh, J. H., Kim, W., Park, K. U., & Roh, Y. H.
Venue
The American Journal of Sports Medicine
Published
2015-10-15
Volume
43
Issue
12
Pages
3062-3070
ISSN
  • 0363-5465 (ISSN-L)
  • 1552-3365
OpenAlex
W2179095191
Cited by
162
References
4
FWCI
15.99
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of the Cellular Composition and Cytokine-Release Kinetics of Various Platelet-Rich Plasma Preparations. https://app.cochat.ai/papers/10.1177/0363546515608481
The paper
Oh, J. H., Kim, W., Park, K. U., & Roh, Y. H. (2015). Comparison of the Cellular Composition and Cytokine-Release Kinetics of Various Platelet-Rich Plasma Preparations. The American Journal of Sports Medicine. https://doi.org/10.1177/0363546515608481

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.