Graft Diameter as a Predictor for Revision Anterior Cruciate Ligament Reconstruction and KOOS and EQ-5D Values: A Cohort Study From the Swedish National Knee Ligament Register Based on 2240 Patients
The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
Background: Anterior cruciate ligament (ACL) reconstruction (ACLR) using a hamstring tendon (HT) autograft is an effective and widespread method. Recent studies have identified a relationship between the graft diameter and revision ACLR. Purpose: To evaluate the influence of the graft diameter on revision ACLR and patient-reported outcomes in patients undergoing primary ACLR using HT autografts. Study Design: Cohort study; Level of evidence, 2. Methods: A prospective cohort study was conducted using the Swedish National Knee Ligament Register (SNKLR) involving all patients undergoing primary ACLR using HT autografts. Patients with graft failure who needed revision surgery (cases) were compared with patients not undergoing revision surgery (controls). The control group was matched for sex, age, and graft fixation method in a 3:1 ratio. Conditional logistic regression was performed to produce odds ratios and 95% CIs. Univariate linear regression analyses were performed for patient-related outcomes. The Knee injury and Osteoarthritis Outcome Score (KOOS) and EuroQol 5 dimensions questionnaire (EQ-5D) values were obtained. Results: A total of 2240 patients were included in which there were 560 cases and 1680 controls. No significant differences between the cases and controls were found for sex (52.9% male), mean age (21.7 years), and femoral and tibial fixation. The mean graft diameter for the cases was 8.0 ± 0.74 mm and for the controls was 8.1 ± 0.76 mm. In the present cohort, the likelihood of revision surgery for every 0.5-mm increase in the HT autograft diameter between 7.0 and 10.0 mm was 0.86 (95% CI, 0.75-0.99; P = .03). Univariate linear regression analysis found no significant regression coefficient for the change in KOOS or EQ-5D values. Conclusion: In a large cohort of patients after primary ACLR with HT autografts, an increase in the graft diameter between 7.0 and 10.0 mm resulted in a 0.86 times lower likelihood of revision surgery with every 0.5-mm increase. This study provides further evidence of the importance of the HT autograft size in intraoperative decision making.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Grindem, H., Snyder-Mackler, L., Moksnes, H., Engebretsen, L., & Risberg, M. A. (2016) · British Journal of Sports Medicine · doi:10.1136/bjsports-2016-096031 · Cited by 1,313
Magnussen, R. A., Lawrence, J. T. R., West, R. L., Toth, A. P., Taylor, D. C., & Garrett, W. E. (2012) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1016/j.arthro.2011.11.024 · Cited by 679
HAMNER, D. L., BROWN, C. H., STEINER, M. E., HECKER, A. T., & HAYES, W. C. (1999) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199904000-00013 · Cited by 633
Conte, E. J., Hyatt, A. E., Gatt, C. J., & Dhawan, A. (2014) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1016/j.arthro.2014.03.028 · Cited by 436
Mariscalco, M. W., Flanigan, D. C., Mitchell, J., Pedroza, A. D., Jones, M. H., Andrish, J. T., Parker, R. D., Kaeding, C. C., & Magnussen, R. A. (2013) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1016/j.arthro.2013.08.025 · Cited by 424
Ahldén, M., Samuelsson, K., Sernert, N., Forssblad, M., Karlsson, J., & Kartus, J. (2012) · The American Journal of Sports Medicine · doi:10.1177/0363546512457348 · Cited by 390
Self-citationPersson, A., Fjeldsgaard, K., Gjertsen, J.-E., Kjellsen, A. B., Engebretsen, L., Hole, R. M., & Fevang, J. M. (2014) · The American Journal of Sports Medicine · doi:10.1177/0363546513511419 · Cited by 348
Gifstad, T., Foss, O. A., Engebretsen, L., Lind, M., Forssblad, M., Albrektsen, G., & Drogset, J. O. (2014) · The American Journal of Sports Medicine · doi:10.1177/0363546514548164 · Cited by 319
Park, S. Y., Oh, H., Park, S., Lee, J. H., Lee, S. H., & Yoon, K. H. (2013) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/s00167-012-2085-4 · Cited by 233
Spragg, L., Chen, J., Mirzayan, R., Love, R. M., & Maletis, G. B. (2016) · The American Journal of Sports Medicine · doi:10.1177/0363546516634011 · Cited by 214
Rahr-Wagner, L., Thillemann, T. M., Pedersen, A. B., & Lind, M. (2014) · The American Journal of Sports Medicine · doi:10.1177/0363546513509220 · Cited by 207
Andernord, D., Desai, N., Björnsson, H., Ylander, M., Karlsson, J., & Samuelsson, K. (2015) · The American Journal of Sports Medicine · doi:10.1177/0363546514552788 · Cited by 201
Self-citationKamien, P. M., Hydrick, J. M., Replogle, W. H., Go, L. T., & Barrett, G. R. (2013) · The American Journal of Sports Medicine · doi:10.1177/0363546513493896 · Cited by 185
Reinhardt, K. R., Hetsroni, I., & Marx, R. G. (2010) · Orthopedic Clinics of North America · doi:10.1016/j.ocl.2009.12.009 · Cited by 176
van Eck, C. F., Schreiber, V. M., Mejia, H. A., Samuelsson, K., van Dijk, C. N., Karlsson, J., & Fu, F. H. (2010) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1016/j.arthro.2010.03.005 · Cited by 172
Self-citationAnatomic Single- and Double-Bundle Anterior Cruciate Ligament Reconstruction, Part 1: Basic Science
Yasuda, K., van Eck, C. F., Hoshino, Y., Fu, F. H., & Tashman, S. (2011) · The American Journal of Sports Medicine · doi:10.1177/0363546511402659 · Cited by 172
Maletis, G. B., Inacio, M. C. S., Desmond, J. L., & Funahashi, T. T. (2013) · The Bone & Joint Journal · doi:10.1302/0301-620x.95b5.30872 · Cited by 160
Andernord, D., Björnsson, H., Petzold, M., Eriksson, B. I., Forssblad, M. L., Karlsson, J., & Samuelsson, K. (2014) · The American Journal of Sports Medicine · doi:10.1177/0363546514531396 · Cited by 132
Self-citationFältström, A., Hägglund, M., Magnusson, H., Forssblad, M. L., & Kvist, J. (2014) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1007/s00167-014-3406-6 · Cited by 110
Poolman, R. W., Farrokhyar, F., & Bhandari, M. (2007) · Acta Orthopaedica · doi:10.1080/17453670710013915 · Cited by 92
Björnsson, H., Desai, N., Musahl, V., Alentorn‐Geli, E., Bhandari, M., Fu, F. H., & Samuelsson, K. (2013) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1007/s00167-013-2666-x · Cited by 69
Self-citationHerbort, M., Domnick, C., Raschke, M. C. E. J., Lenschow, S., Förster, T., Petersen, W. J., & Zantop, T. (2015) · The American Journal of Sports Medicine · doi:10.1177/0363546515611646 · Cited by 54
Şükür, E., Akman, Y. E., Şenel, A., Ünkar, E. A., Topçu, H. N., & Ozturkmen, A. Y. (2016) · The Open Orthopaedics Journal · doi:10.2174/1874325001610010481 · Cited by 15
Cited by
Cheng, R., Wang, H., Jiang, Z., Dimitriou, D., Cheng, C.-K., & Tsai, T.-Y. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.797389 · Cited by 20
“A 4-strand hamstring tendon graft was simulated as cylindrical with a diameter of 7mm (Goyal et al., 2016; Snaebjörnsson et al., 2017; Alomar et al., 2021) and Young’s modulus of 144.8MPa (Wilson et al., 1999).”
Method
Metadata
- Authors
- Snaebjörnsson, T., Hamrin Senorski, E., Ayeni, O. R., Alentorn-Geli, E., Krupic, F., Norberg, F., Karlsson, J., & Samuelsson, K.
- Venue
- The American Journal of Sports Medicine
- Publisher
- SAGE Publications
- Published
- 2017-05-01
- Volume
- 45
- Issue
- 9
- Pages
- 2092-2097
- ISSN
- 0363-5465 (ISSN-L)
- 1552-3365
- OpenAlex
- W2611558877
- Cited by
- 183
- References
- 23
- FWCI
- 13.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.