Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 219

The DOI matches its Crossref record.

Repeatability of the KT-1000 arthrometer in a normal population

Wroble, Randall R., Van Ginkel, Laura A., Grood, Edward S., Noyes, Frank R., Shaffer, Brian L.·1990·The American Journal of Sports Medicine

Abstract

Despite its popularity, the MEDmetric KT-1000 arthro meter's reliability remains inadequately documented. We conducted this study to determine the magnitude of trial-to-trial (within installation), installation-to-instal lation (within day), and day-to-day (between day) vari ability of anterior/posterior translation measurements in normal knees. We selected six normal subjects, three males and three females, and tested each on 6 consecutive days with three separate installations per day. We recorded the total anterior/posterior translation at ±89 and ±134 N force at 25° of flexion during three consecutive trials in a single installation. Analysis of variance showed that no significant differ ence existed between trials (within installation) or be tween installations (within day) for all parameters. How ever, we did find a significant difference between days for individual right and left knee translation measure ments at 89 and 134 N force. More importantly, no significant difference existed between days for right to left differences at both force levels. The magnitude of the expected measurement varia bility was expressed by computing 90% confidence limits for total anterior/posterior translation at ±89 N force. These were ±1.5 mm for the right knees, ±1.4 mm for the left knees, and ±1.6 mm for the right-left differences. Fischer's protected least significant differ ence post hoc test revealed that for all parameters, the 1 st day measurements were significantly less than those on following days, suggesting that patient and examiner adjust to the testing procedure. We conclude that the standard KT-1000 evaluation should report paired differences rather than individual knee measurements. Additionally, initial evaluation should be supplemented by follow-up examinations for verifying translation values.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/036354659001800411

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 219

Metadata

Authors
Wroble, R. R., Van Ginkel, L. A., Grood, E. S., Noyes, F. R., & Shaffer, B. L.
Venue
The American Journal of Sports Medicine
Published
1990-07
Volume
18
Issue
4
Pages
396-399
ISSN
  • 0363-5465 (ISSN-L)
  • 1552-3365
OpenAlex
W1992657478
Cited by
219
References
0
FWCI
8.85
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Repeatability of the KT-1000 arthrometer in a normal population. https://app.cochat.ai/papers/10.1177/036354659001800411
The paper
Wroble, R. R., Van Ginkel, L. A., Grood, E. S., Noyes, F. R., & Shaffer, B. L. (1990). Repeatability of the KT-1000 arthrometer in a normal population. The American Journal of Sports Medicine. https://doi.org/10.1177/036354659001800411

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.