Repeatability of the KT-1000 arthrometer in a normal population
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Despite its popularity, the MEDmetric KT-1000 arthro meter's reliability remains inadequately documented. We conducted this study to determine the magnitude of trial-to-trial (within installation), installation-to-instal lation (within day), and day-to-day (between day) vari ability of anterior/posterior translation measurements in normal knees. We selected six normal subjects, three males and three females, and tested each on 6 consecutive days with three separate installations per day. We recorded the total anterior/posterior translation at ±89 and ±134 N force at 25° of flexion during three consecutive trials in a single installation. Analysis of variance showed that no significant differ ence existed between trials (within installation) or be tween installations (within day) for all parameters. How ever, we did find a significant difference between days for individual right and left knee translation measure ments at 89 and 134 N force. More importantly, no significant difference existed between days for right to left differences at both force levels. The magnitude of the expected measurement varia bility was expressed by computing 90% confidence limits for total anterior/posterior translation at ±89 N force. These were ±1.5 mm for the right knees, ±1.4 mm for the left knees, and ±1.6 mm for the right-left differences. Fischer's protected least significant differ ence post hoc test revealed that for all parameters, the 1 st day measurements were significantly less than those on following days, suggesting that patient and examiner adjust to the testing procedure. We conclude that the standard KT-1000 evaluation should report paired differences rather than individual knee measurements. Additionally, initial evaluation should be supplemented by follow-up examinations for verifying translation values.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Instrumented measurement of anterior laxity of the knee.
Daniel, D. M., Malcom, L. L., Losse, G., Stone, M. L., Sachs, R., & Burks, R. (1985) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198567050-00006 · Cited by 749
Daniel, D. M., Stone, M. L., Sachs, R., & Malcom, L. (1985) · The American Journal of Sports Medicine · doi:10.1177/036354658501300607 · Cited by 679
In vivo knee stability. A quantitative assessment using an instrumented clinical testing apparatus.
Markolf, K. L., Graff-Radford, A., & Amstutz, H. C. (1978) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197860050-00014 · Cited by 398
Is the KT1000 knee ligament arthrometer reliable?
Forster, I., Warren-Smith, C., & Tew, M. (1989) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.71b5.2584257 · Cited by 138
Cited by
Evaluation of knee ligament injuries with the IKDC form
Hefti, F., Müller, W., Jakob, R. P., & Stäubli, H. ‐. (1993) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/bf01560215 · Cited by 1,569
Fate of the ACL-injured Patient: A Prospective Outcome Study
Daniel, D. M., Stone, M. L., Dobson, B. E., Fithian, D. C., Rossman, D. J., & Kaufman, K. R. (1994) · The American Journal of Sports Medicine · doi:10.1177/036354659402200511 · Cited by 1,240
Noyes, F. R., Barber, S. D., & Mangine, R. E. (1991) · The American Journal of Sports Medicine · doi:10.1177/036354659101900518 · Cited by 995
Self-citationAune, A. K., Holm, I., Risberg, M. A., Jensen, H. K., & Steen, H. (2001) · The American Journal of Sports Medicine · doi:10.1177/03635465010290060901 · Cited by 420
Laxity in healthy and osteoarthritic knees
Sharma, L., Lou, C., Felson, D. T., Dunlop, D. D., Kirwan-Mellis, G., Hayes, K. W., Weinrach, D., & Buchanan, T. S. (1999) · Arthritis & Rheumatism · doi:10.1002/1529-0131(199905)42:5<861::aid-anr4>3.0.co;2-n · Cited by 287
Mikkelsen, C., Werner, S., & Eriksson, E. (2000) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/s001670000143 · Cited by 283
Anterior Cruciate Ligament Allograft Reconstruction in the Skeletally Immature Athlete
Andrews, M., Noyes, F. R., & Barber-Westin, S. D. (1994) · The American Journal of Sports Medicine · doi:10.1177/036354659402200109 · Cited by 273
Self-citationNeuromuscular Performance in Normal and Anterior Cruciate Ligament-Deficient Lower Extremities
Wojtys, E. M., & Huston, L. J. (1994) · The American Journal of Sports Medicine · doi:10.1177/036354659402200116 · Cited by 272
Revision Anterior Cruciate Surgery with Use of Bone-Patellar Tendon-Bone Autogenous Grafts
Noyes, F. R., & Barber-Westin, S. D. (2001) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200108000-00001 · Cited by 257
Self-citationEitzen, I., Moksnes, H., Snyder-Mackler, L., & Risberg, M. A. (2010) · Journal of Orthopaedic & Sports Physical Therapy · doi:10.2519/jospt.2010.3345 · Cited by 246
Ristanis, S., Giakas, G., Papageorgiou, C. D., Moraiti, T., Stergiou, N., & Georgoulis, A. D. (2003) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/s00167-003-0428-x · Cited by 227
“[28] we hypothesized that tibial rotation during this high stress activity is greater in the ACL reconstructed knee than the contralateral intact knee.”
InfluentialHolm, I., Øiestad, B. E., Risberg, M. A., & Aune, A. K. (2010) · The American Journal of Sports Medicine · doi:10.1177/0363546509350301 · Cited by 222
“Knee joint laxity was recorded using a KT-1000 knee arthrometer (MEDmetric Corp, San Diego, California) at the manual maximum force.(20) The difference in displacement in millimeters between the operated and nonoperated knee was recorded.”
MethodPeripheral joint laxity increases in pregnancy but does not correlate with serum relaxin levels
Schauberger, C. W., Rooney, B. L., Goldsmith, L., Shenton, D., Silva, P. D., & Schaper, A. (1996) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(96)70447-7 · Cited by 207
NOYES, F. R., & BARBER-WESTIN, S. D. (1996) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199604000-00006 · Cited by 175
Self-citationThe Effects of the Menstrual Cycle on Anterior Knee Laxity: A Systematic Review
Zazulak, B. T., Paterno, M., Myer, G. D., Romani, W. A., & Hewett, T. E. (2006) · Sports Medicine · doi:10.2165/00007256-200636100-00004 · Cited by 170
The Effect of Knee Bracing After Anterior Cruciate Ligament Reconstruction
Risberg, M. A., Holm, I., Steen, H., Eriksson, J., & Ekeland, A. (1999) · The American Journal of Sports Medicine · doi:10.1177/03635465990270012101 · Cited by 164
“Knee joint laxity (anterior displacement of the tibia relative to the femur) was recorded with the KT-1000 arthrometer (MEDmetric, San Diego, California) at 89 N, 134 N, and the manual maximum force.(51) The tests were performed with the patient in a supine position with a standard bar beneath the thighs, representing…”
MethodUse of allografts after failed treatment of rupture of the anterior cruciate ligament.
Noyes, F. R., Barber-Westin, S. D., & Roberts, C. S. (1994) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199407000-00010 · Cited by 159
Self-citationA new approach to measure functional stability of the knee based on changes in knee axis orientation
Grip, H., & Häger, C. (2013) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2012.12.015 · Cited by 46
“KT-1000 is the best available method to estimate knee laxity in the clinic, but leg position during measurement and examiner experience may affect the results (Ballantyne et al., 1995; Berry et al., 1999; Forster et al., 1989; Wroble et al., 1990).”
Method
Metadata
- Authors
- Wroble, R. R., Van Ginkel, L. A., Grood, E. S., Noyes, F. R., & Shaffer, B. L.
- Venue
- The American Journal of Sports Medicine
- Publisher
- SAGE Publications
- Published
- 1990-07
- Volume
- 18
- Issue
- 4
- Pages
- 396-399
- ISSN
- 0363-5465 (ISSN-L)
- 1552-3365
- OpenAlex
- W1992657478
- Cited by
- 219
- References
- 4
- FWCI
- 8.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.