The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Long-term Results of Arthroscopic Meniscal Repair: An Analysis of Isolated Tears
Abstract
From 1984 through 1986 we performed 54 arthroscopic meniscal repairs on patients with anterior cruciate ligament-stable knees. We evaluated the repair results of 52 of these patients at an average followup of 7.5 years. In 40 patients the meniscal repairs had not failed and these patients were examined clinically and radio- graphically ; in 25 cases, magnetic resonance imaging was also performed. Significantly more failures ( P ≤ 0.05) occurred when the rim width of the tear was greater than 3 mm and when the tear was repaired with resorbable sutures. Conversely, the following factors were found to favorably influence meniscal healing (P > 0.05): time from injury to surgery less than 8 weeks, patient age less than 30 years, tear length less than 2.5 cm, and tear in the lateral meniscus. The overall failure rate after 7.5 years was 27% (14 of 52); 64% (9 of 14) of the failures occurred in the first 6 months after repair. The clinical and radiographic evaluation of the success fully repaired knees showed that 90% (36 of 40) had normal knee function; the remaining 10% (4 patients) had nearly normal knee function. Magnetic resonance imaging, however, showed a persisting grade 3 or 4 lesion in 96% (24 of 25) of the successfully repaired menisci and is therefore not reliable in assessing me niscal healing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Microvasculature of the human meniscus
Arnoczky, S. P., & Warren, R. F. (1982) · The American Journal of Sports Medicine · doi:10.1177/036354658201000205 · Cited by 1,239
Clark, C. R., & Ogden, J. A. (1983) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198365040-00018 · Cited by 481
Scott, G. A., Jolly, B. L., & Henning, C. E. (1986) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198668060-00006 · Cited by 414
Cooper, D. E., Arnoczky, S. P., & Warren, R. F. (1990) · Clinics in Sports Medicine · doi:10.1016/s0278-5919(20)30710-9 · Cited by 285
The vascular and nerve supply of the human meniscus
Day, B., Mackenzie, W. G., Shim, S. S., & Leung, G. (1985) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1016/s0749-8063(85)80080-3 · Cited by 230
Repair of peripheral meniscal tears: Open versus arthroscopic technique
Hanks, G. A., Gause, T. M., Sebastianelli, W. J., O'Donnell, C. S., & Kalenak, A. (1991) · Arthroscopy The Journal of Arthroscopic and Related Surgery · doi:10.1016/0749-8063(91)90082-9 · Cited by 75
Cited by
Makris, E. A., Hadidi, P., & Athanasiou, K. A. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.06.037 · Cited by 1,116
Ishida, K., Kuroda, R., Miwa, M., Tabata, Y., Hokugo, A., Kawamoto, T., Sasaki, K., Doita, M., & Kurosaka, M. (2007) · Tissue Engineering · doi:10.1089/ten.2006.0193 · Cited by 345
The central ACL defect as a model for failure of intra‐articular healing
Spindler, K. P., Murray, M. M., Devin, C., Nanney, L. B., & Davidson, J. M. (2006) · Journal of Orthopaedic Research · doi:10.1002/jor.20074 · Cited by 56
Metadata
- Authors
- Eggli, S., Wegmüller, H., Kosina, J., Huckell, C., & Jakob, R. P.
- Venue
- The American Journal of Sports Medicine
- Publisher
- SAGE Publications
- Published
- 1995-11
- Volume
- 23
- Issue
- 6
- Pages
- 715-720
- ISSN
- 0363-5465 (ISSN-L)
- 1552-3365
- OpenAlex
- W2082088348
- Cited by
- 277
- References
- 6
- FWCI
- 3.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Long-term Results of Arthroscopic Meniscal Repair: An Analysis of Isolated Tears. https://app.cochat.ai/papers/10.1177/036354659502300614
- The paper
- Eggli, S., Wegmüller, H., Kosina, J., Huckell, C., & Jakob, R. P. (1995). Long-term Results of Arthroscopic Meniscal Repair: An Analysis of Isolated Tears. The American Journal of Sports Medicine. https://doi.org/10.1177/036354659502300614
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.