Central Quadriceps Tendon for Anterior Cruciate Ligament Reconstruction: Part I: Morphometric and Biomechanical Evaluation
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
We examined the anatomic and biomechanical adequacy of the central quadriceps tendon as an al ternative graft source for anterior cruciate ligament reconstruction. Morphometry was performed on 15 preserved and 6 fresh-frozen specimens. Biomechani cal testing was performed on the six fresh-frozen spec imens. We initially used a triple suture through the tendon construction, and then clamping directly on the tendon. Morphometry yielded the following meas urements: length, 6.1 ± 1.0 cm; width, 2.7 cm (range, 2.1 to 3.7); and thickness, 7 mm (range, 6.4 to 7.8). The thickness was 1.8 times that of the patellar tendon. Biomechanical testing showed that suture failure oc curred at 692 ± 181 N, and tendon failure occurred at 1075 ± 449 N. The load to tendon failure was 1.36 times that of a comparable-width patellar tendon graft, although the difference was not statistically significant. The failure mode was primarily through partial or com plete tendinous avulsion, with only one specimen fail ing at midsubstance. These findings show the central quadriceps graft is of sufficient size and strength to be used for anterior cruciate ligament reconstruction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biomechanical analysis of human ligament grafts used in knee-ligament repairs and reconstructions.
Noyes, F. R., Butler, D. L., Grood, E. S., Zernicke, R. F., & Hefzy, M. S. (1984) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198466030-00005 · Cited by 1,524
The strength of the anterior cruciate ligament in humans and Rhesus monkeys
Noyes, F., & Grood, E. (1976) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197658080-00006 · Cited by 826
Jackson, D. W., Grood, E. S., Goldstein, J. D., Rosen, M. A., Kurzweil, P. R., Cummings, J. F., & Simon, T. M. (1993) · The American Journal of Sports Medicine · doi:10.1177/036354659302100203 · Cited by 501
The anterior aspect of the knee joint.
Reider, B., Marshall, J. L., Koslin, B., Ring, B., & Girgis, F. G. (1981) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198163030-00004 · Cited by 297
Howe, J. G., Johnson, R. J., Kaplan, M. J., Fleming, B., & Jarvinen, M. (1991) · The American Journal of Sports Medicine · doi:10.1177/036354659101900505 · Cited by 230
An alternative cruciate reconstruction graft: The central quadriceps tendon
Fulkerson, J. P., & Langeland, R. (1995) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1016/0749-8063(95)90078-0 · Cited by 207
Nikolaou, P. K., Seaber, A. V., Glisson, R. R., Ribbeck, B. M., & Bassett, F. H. (1986) · The American Journal of Sports Medicine · doi:10.1177/036354658601400502 · Cited by 198
Blevins, F. T., Hecker, A. T., Bigler, G. T., Boland, A. L., & Hayes, W. C. (1994) · The American Journal of Sports Medicine · doi:10.1177/036354659402200306 · Cited by 185
Biologic Incorporation of Allograft Anterior Cruciate Ligament Replacements
Jackson, D. W., Corsetti, J., & Simon, T. M. (1996) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199603000-00015 · Cited by 165
The GORE-TEX anterior cruciate ligament prosthesis
Paulos, L. E., Rosenberg, T. D., Grewe, S. R., Tearse, D. S., & Beck, C. L. (1992) · The American Journal of Sports Medicine · doi:10.1177/036354659202000302 · Cited by 137
Cited by
Mouarbes, D., Menetrey, J., Marot, V., Courtot, L., Berard, E., & Cavaignac, E. (2019) · The American Journal of Sports Medicine · doi:10.1177/0363546518825340 · Cited by 484
Slone, H. S., Romine, S. E., Premkumar, A., & Xerogeanes, J. W. (2015) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1016/j.arthro.2014.11.010 · Cited by 335
Shani, R. H., Umpierez, E., Nasert, M., Hiza, E. A., & Xerogeanes, J. (2016) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1016/j.arthro.2015.06.051 · Cited by 199
Reinhardt, K. R., Hetsroni, I., & Marx, R. G. (2010) · Orthopedic Clinics of North America · doi:10.1016/j.ocl.2009.12.009 · Cited by 176
Recent Advances in the Rehabilitation of Anterior Cruciate Ligament Injuries
Wilk, K. E., Macrina, L. C., Cain, E. L., Dugas, J. R., & Andrews, J. R. (2012) · Journal of Orthopaedic & Sports Physical Therapy · doi:10.2519/jospt.2012.3741 · Cited by 173
Anterior Cruciate Ligament Reconstruction: Quadriceps Versus Patellar Autograft
Han, H. S., Seong, S. C., Lee, S., & Lee, M. C. (2008) · Clinical Orthopaedics & Related Research · doi:10.1007/s11999-007-0015-4 · Cited by 167
Three-Dimensional Dynamic Simulation of Total Knee Replacement Motion During a Step-Up Task
Piazza, S. J., & Delp, S. L. (2001) · Journal of Biomechanical Engineering · doi:10.1115/1.1406950 · Cited by 158
Quadriceps tendon anterior cruciate ligament reconstruction
Diermeier, T., Tisherman, R., Hughes, J., Tulman, M., Baum Coffey, E., Fink, C., Lynch, A., Fu, F. H., & Musahl, V. (2020) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/s00167-020-05902-z · Cited by 83
“In contrast, a full-thickness QT harvested with a bone block without the retinaculum has been demonstrated to have equivalent load to failure as compared to BPTB [25, 63].”
Result
Metadata
- Authors
- Harris, N. L., Smith, D. A. B., Lamoreaux, L., & Purnell, M.
- Venue
- The American Journal of Sports Medicine
- Publisher
- SAGE Publications
- Published
- 1997-01
- Volume
- 25
- Issue
- 1
- Pages
- 23-28
- ISSN
- 0363-5465 (ISSN-L)
- 1552-3365
- OpenAlex
- W2029948214
- Cited by
- 212
- References
- 14
- FWCI
- 3.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.