Development of a Hybrid Artificial Liver Using Polyurethane Foam / Hepatocyte Spheroid Culture in a Preclinical Pig Experiment
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
We describe a preclinical study of our original hybrid artificial liver support system (HALSS) for a clinical trial. We designed a HALSS comprising a multi-capillary polyurethane foam packed-bed module (MC-PUF module) containing a total 200 g (2 × 10 10 cells) porcine hepatocytes, and an extracorporeal circulation device. Almost all porcine hepatocytes in the MC-PUF module formed many spherical multicellular aggregates (spheroids). This extracorporeal circulation device was improved to promote solute exchange between a living body and a MC-PUF module by including a plasma bypass line in the circulation loop. The efficacy of the HALSS was evaluated using a 25-kg pig with warm ischemic liver failure by portocaval shunt and ligation of hepatic artery (HALSS group, n=3). As a control experiment, the same system without hepatocytes in the module was used with the same kind of liver failure pig (Control group, n=3). The blood ammonia in the control group was 143 N-μg/dl at the start of circulation, and rapidly increased to 351 N-μg/dl at 2 hours and to 704 N-μg/dl at 6 hours. But the blood ammonia in the HALSS group was completely suppressed, and remained less than the hepatic coma level (over 200 N-μg/dl) during the circulation time. The blood glucose in the control group gradually decreased, and became less than 40 mg/dl within 6 hours of circulation. But the blood glucose in the HALSS group was maintained well, and remained the normal glucose level (50 – 105 mg/dl) for more than 20 hours of circulation. Improvement in blood creatinine and lactate, and the stabilization of vital signs and urinary excretion, were observed in the HALSS group. The survival time of the pigs in the HALSS group was 19.3 hours compared with 8.9 hours in the control group. In conclusion, our HALSS was effective to stabilize the general conditions of the body in addition to supporting various liver functions. These results suggest that our HALSS has a strong possibility to be used in treating liver failure patients. We have applied for approval of the clinical trial of our HALSS to our institutional ethics committee.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Artificial Liver Support: State of the Art
Dixit, V., & Gitnick, G. (1996) · Scandinavian Journal of Gastroenterology · doi:10.3109/00365529609094760 · Cited by 42 · cited 1×
“Currently, various artificial liver modules have been developed, such as those using hollow fiber (1 - 5), nonwoven fabric (6, 7), a microcapsule packed-bed (8, 9) and multiple plates (10, 11).”
Background
Cited by
Design of artificial extracellular matrices for tissue engineering
Kim, B.-S., Park, I.-K., Hoshiba, T., Jiang, H.-L., Choi, Y.-J., Akaike, T., & Cho, C.-S. (2011) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2010.10.001 · Cited by 296
Takezawa, T., Ozaki, K., Nitani, A., Takabayashi, C., & Shimo-Oka, T. (2004) · Cell Transplantation · doi:10.3727/000000004783983882 · Cited by 165
Reconstruction of renal glomerular tissue using collagen vitrigel scaffold
Wang, P.-C., & Takezawa, T. (2005) · Journal of Bioscience and Bioengineering · doi:10.1263/jbb.99.529 · Cited by 59
Fukuda, J., Okamura, K., Nakazawa, K., Ijima, H., Yamashita, Y., Shimada, M., Shirabe, K., Tsujita, E., Sugimachi, K., & Funatsu, K. (2003) · Cell Transplantation · doi:10.3727/000000003783985151 · Cited by 54
Self-citation
Metadata
- Authors
- Nakazawa, K., Ijima, H., Fukuda, J., Sakiyama, R., Yamashita, Y., Shimada, M., Shirabe, K., Tsujita, E., Sugimachi, K., & Funatsu, K.
- Venue
- The International Journal of Artificial Organs
- Publisher
- SAGE Publications
- Published
- 2002-01
- Volume
- 25
- Issue
- 1
- Pages
- 51-60
- ISSN
- 0391-3988 (ISSN-L)
- 1724-6040
- OpenAlex
- W2295721027
- Cited by
- 50
- References
- 1
- FWCI
- 6.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Development of a Hybrid Artificial Liver Using Polyurethane Foam / Hepatocyte Spheroid Culture in a Preclinical Pig Experiment. https://app.cochat.ai/papers/10.1177/039139880202500109
- The paper
- Nakazawa, K., Ijima, H., Fukuda, J., Sakiyama, R., Yamashita, Y., Shimada, M., Shirabe, K., Tsujita, E., Sugimachi, K., & Funatsu, K. (2002). Development of a Hybrid Artificial Liver Using Polyurethane Foam / Hepatocyte Spheroid Culture in a Preclinical Pig Experiment. The International Journal of Artificial Organs. https://doi.org/10.1177/039139880202500109
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.