Early Experiences with a Porcine Hepatocyte-based Bioartificial Liver in Acute Hepatic Failure Patients
Open accessThe DOI matches its Crossref record.
Abstract
Orthotopic liver transplantation (OLT) is the only effective therapeutic modality in severe acute hepatic failure (AHF). The scarcity of organs for transplantation leads to an urgent necessity for temporary liver support treatments in AHF patients. A hepatocyte-based bioartificial liver (BAL) is under investigation with the main purpose to serve as bridging treatment until a liver becomes available for OLT, or to promote spontaneous liver regeneration. We developed a novel radial-flow bioreactor (RFB) for three-dimensional, high-density hepatocyte culture and an integrated pumping apparatus in which, after plasmapheresis, the patient's plasma is recirculated through the hepatocyte-filled RFB. Two hundred thirty grams of freshly isolated porcine hepatocytes were loaded into the RFB for clinical liver support treatment. The BAL system was used 8 times in supporting 7 AHF patients in grade III-IV coma, all waiting for an urgent OLT. Three patients with no history of previous liver diseases were affected by fulminant hepatic failure (FHF) due to hepatitis B virus, 3 by primary non-function (PNF) of the transplanted liver, and one by AHF due to previous abdominal trauma and liver surgery. Six out of 7 patients underwent OLT following BAL treatment(s), which lasted 6–24 hours. All patients tolerated the procedures well, as shown by an improvement in the level of encephalopathy, a decrease in serum ammonia, transaminases and an amelioration of the prothrombin time, with full neurological recovery after OLT. Our initial clinical experience confirms the safety of this BAL configuration and suggests its clinical efficacy as a temporary liver support system in AHF patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Clinical Application of Bioartificial Liver Support Systems
van de Kerkhove, M. P., Hoekstra, R., Chamuleau, R. A. F. M., & van Gulik, T. M. (2004) · Annals of Surgery · doi:10.1097/01.sla.0000132986.75257.19 · Cited by 210
Liver tissue engineering and cell sources: issues and challenges
Palakkan, A. A., Hay, D. C., PR, A. K., TV, K., & Ross, J. A. (2013) · Liver International · doi:10.1111/liv.12134 · Cited by 130
Nguyen, T. H., Mai, G., Villiger, P., Oberholzer, J., Salmon, P., Morel, P., Bühler, L., & Trono, D. (2005) · Journal of Hepatology · doi:10.1016/j.jhep.2005.05.036 · Cited by 53
Diekmann, S., Bader, A., & Schmitmeier, S. (2006) · Cytotechnology · doi:10.1007/s10616-006-6336-4 · Cited by 32
Metadata
- Authors
- Morsiani, E., Pazzi, P., Puviani, A. C., Brogli, M., Valieri, L., Gorini, P., Scoletta, P., Marangoni, E., Ragazzi, R., Azzena, G., Frazzoli, E., Di Luca, D., Cassai, E., Lombardi, G., Cavallari, A., Faenza, S., Pasetto, A., Girardis, M., Jovine, E., & Pinna, A. D.
- Venue
- The International Journal of Artificial Organs
- Publisher
- SAGE Publications
- Published
- 2002-03
- Volume
- 25
- Issue
- 3
- Pages
- 192-202
- ISSN
- 0391-3988 (ISSN-L)
- 1724-6040
- OpenAlex
- W2194468818
- Cited by
- 93
- References
- 0
- FWCI
- 8.77
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Early Experiences with a Porcine Hepatocyte-based Bioartificial Liver in Acute Hepatic Failure Patients. https://app.cochat.ai/papers/10.1177/039139880202500305
- The paper
- Morsiani, E., Pazzi, P., Puviani, A. C., Brogli, M., Valieri, L., Gorini, P., Scoletta, P., Marangoni, E., Ragazzi, R., Azzena, G., Frazzoli, E., Di Luca, D., Cassai, E., Lombardi, G., Cavallari, A., Faenza, S., Pasetto, A., Girardis, M., Jovine, E., & Pinna, A. D. (2002). Early Experiences with a Porcine Hepatocyte-based Bioartificial Liver in Acute Hepatic Failure Patients. The International Journal of Artificial Organs. https://doi.org/10.1177/039139880202500305
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.