CoChat

Early Experiences with a Porcine Hepatocyte-based Bioartificial Liver in Acute Hepatic Failure Patients

Open access
Morsiani, E., Pazzi, P., Puviani, A.C., Brogli, M., Valieri, L., Gorini, P., Scoletta, P., Marangoni, E., Ragazzi, R., Azzena, G., Frazzoli, E., Di Luca, D., Cassai, E., Lombardi, G., Cavallari, A., Faenza, S., Pasetto, A., Girardis, M., Jovine, E., Pinna, A.D. · 2002 · The International Journal of Artificial Organs
Cited by 93

The DOI matches its Crossref record.

Abstract

Orthotopic liver transplantation (OLT) is the only effective therapeutic modality in severe acute hepatic failure (AHF). The scarcity of organs for transplantation leads to an urgent necessity for temporary liver support treatments in AHF patients. A hepatocyte-based bioartificial liver (BAL) is under investigation with the main purpose to serve as bridging treatment until a liver becomes available for OLT, or to promote spontaneous liver regeneration. We developed a novel radial-flow bioreactor (RFB) for three-dimensional, high-density hepatocyte culture and an integrated pumping apparatus in which, after plasmapheresis, the patient's plasma is recirculated through the hepatocyte-filled RFB. Two hundred thirty grams of freshly isolated porcine hepatocytes were loaded into the RFB for clinical liver support treatment. The BAL system was used 8 times in supporting 7 AHF patients in grade III-IV coma, all waiting for an urgent OLT. Three patients with no history of previous liver diseases were affected by fulminant hepatic failure (FHF) due to hepatitis B virus, 3 by primary non-function (PNF) of the transplanted liver, and one by AHF due to previous abdominal trauma and liver surgery. Six out of 7 patients underwent OLT following BAL treatment(s), which lasted 6–24 hours. All patients tolerated the procedures well, as shown by an improvement in the level of encephalopathy, a decrease in serum ammonia, transaminases and an amelioration of the prothrombin time, with full neurological recovery after OLT. Our initial clinical experience confirms the safety of this BAL configuration and suggests its clinical efficacy as a temporary liver support system in AHF patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/039139880202500305

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 93

Metadata

Authors
Morsiani, E., Pazzi, P., Puviani, A. C., Brogli, M., Valieri, L., Gorini, P., Scoletta, P., Marangoni, E., Ragazzi, R., Azzena, G., Frazzoli, E., Di Luca, D., Cassai, E., Lombardi, G., Cavallari, A., Faenza, S., Pasetto, A., Girardis, M., Jovine, E., & Pinna, A. D.
Venue
The International Journal of Artificial Organs
Published
2002-03
Volume
25
Issue
3
Pages
192-202
ISSN
  • 0391-3988 (ISSN-L)
  • 1724-6040
OpenAlex
W2194468818
Cited by
93
References
0
FWCI
8.77
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Early Experiences with a Porcine Hepatocyte-based Bioartificial Liver in Acute Hepatic Failure Patients. https://app.cochat.ai/papers/10.1177/039139880202500305
The paper
Morsiani, E., Pazzi, P., Puviani, A. C., Brogli, M., Valieri, L., Gorini, P., Scoletta, P., Marangoni, E., Ragazzi, R., Azzena, G., Frazzoli, E., Di Luca, D., Cassai, E., Lombardi, G., Cavallari, A., Faenza, S., Pasetto, A., Girardis, M., Jovine, E., & Pinna, A. D. (2002). Early Experiences with a Porcine Hepatocyte-based Bioartificial Liver in Acute Hepatic Failure Patients. The International Journal of Artificial Organs. https://doi.org/10.1177/039139880202500305

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.