CoChat

Differences in Circadian Photosensitivity between Retinally Degenerate CBA/J Mice (rd/rd) and Normal CBA/N Mice (+/+)

Yoshimura, Takashi, Nishio, Miyuki, Goto, Maki, Ebihara, Shizufumi · 1994 · Journal of Biological Rhythms
Cited by 33

The DOI matches its Crossref record.

Abstract

Using the magnitude of phase shift of circadian locomotor rhythms induced by a single pulse of white fluorescent light, we compared the sensitivity of the circadian system to light in retinally degenerate mice and in normal mice. In the first experiment, phase response curves (PRCs) for 10- lux white light were generated in CBA/J mice with retinal degeneration ( rd/rd) and CBA/N mice with normal retinas (+/+). Although large phase delays early in the subjective night and small phase advances in the late subjective night were observed in CBA/N mice, CBA/J mice showed only small phase delays early in the subjective night. In the second experiment, we found that the magnitude of phase shifts at circadian time (CT) 16 for delays and CT 24 for advances in CBA/J mice became larger with increasing light intensity, and that CBA/J mice could show the same amount of phase shift as CBA/N mice when higher intensities were used. These findings indicate that the differences in the shapes of PRCs are not due to differences in the nature of the oscillating system, but to differences in circadian photosensitivity between these strains. Because the genetic background for the rd loci was not completely identical in the CBA/N and CBA/J mice, it was possible that genes other than the rd gene might have caused different photosensitivity in these mice. Therefore, in the last experiment, we studied the circadian photosensitivity in F 1 hybrids between CBA/N and CBA/J mice and in the backcross progeny with different genotypes (+/ rd and rd/rd) obtained from the crossing between F 1 hybrids between CBA/N and CBA/J mice and in the backcross progeny with different genotypes (+ / rd and rd/rd ) obtained from the crossing between F 1 and CBA/J mice. In these mice with heterogeneous genetic backgrounds as well, mice with retinal degeneration were always less sensitive to light, suggesting that reduced circadian photosensitivity is caused by retinal degeneration. These results are discussed in relation to recent findings in retinally degenerate C57BL mice, which have been found to have normal circadian sensitivity to light.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/074873049400900105

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 33

Metadata

Authors
Yoshimura, T., Nishio, M., Goto, M., & Ebihara, S.
Venue
Journal of Biological Rhythms
Published
1994-03
Volume
9
Issue
1
Pages
51-60
ISSN
  • 0748-7304 (ISSN-L)
  • 1552-4531
OpenAlex
W2070457932
Cited by
33
References
0
FWCI
0.21
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Differences in Circadian Photosensitivity between Retinally Degenerate CBA/J Mice (rd/rd) and Normal CBA/N Mice (+/+). https://app.cochat.ai/papers/10.1177/074873049400900105
The paper
Yoshimura, T., Nishio, M., Goto, M., & Ebihara, S. (1994). Differences in Circadian Photosensitivity between Retinally Degenerate CBA/J Mice (rd/rd) and Normal CBA/N Mice (+/+). Journal of Biological Rhythms. https://doi.org/10.1177/074873049400900105

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.