The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Biocompatibility of the Bioelastic Materials, Poly(GVGVP) and Its γ-Irradiation Cross-Linked Matrix: Summary of Generic Biological Test Results
Abstract
The complete series of the recommended generic biological tests for materials and devices in contact with tissues and tissue fluids and blood have been carried out by an independent testing laboratory on the elastic protein-based (bioelastic) polymer, Poly(L-Val 1-L-Pro 2-Gly 3-L-Val 4-Gly 5) with a degree of polymerization greater than 120, and its 20 Mrad γ-irradiation cross linked elastic matrix, X 20-poly(VPGVG). The specific tests and the summarized results given in parentheses are: (1) the Ames mutagenicity test (non- mutagenic), (2) cytotoxicity-agarose overlay (non-toxic), (3) acute systemic tox icity (non-toxic), (4) intracutaneous toxicity (non-toxic), (5) muscle implantation (favorable), (6) acute intraperitoneal toxicity (non-toxic), (7) systemic antigenic ity (non-antigenic), (8) dermal sensitization—the Magnusson and Kligman maximization method (non-sensitizing), (9) pyrogenicity (non-pyrogenic), (10) Lee White clotting study (normal clotting time), and (11) in vitro hemolysis test (non-hemolytic). Thus, this new elastomeric polypeptide biomaterial which is based on the most striking repeating sequence in the mammalian elastic fiber exhibits an extraordinary biocompatibility. This parent bioelastic material and a wide range of component peptide variations are under development for an equally wide range of potential medical applications such as prevention of adhesions, drug delivery, and synthetic arteries.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ames, B. N., McCann, J., & Yamasaki, E. (1975) · Mutation Research/Environmental Mutagenesis and Related Subjects · doi:10.1016/0165-1161(75)90046-1 · Cited by 7,381
Elastin Structure, Biosynthesis, and Relation to Disease States
Sandberg, L. B., Soskel, N. T., & Leslie, J. G. (1981) · New England Journal of Medicine · doi:10.1056/nejm198103053041004 · Cited by 485
Urry, D. W. (1988) · Journal of Protein Chemistry · doi:10.1007/bf01025411 · Cited by 412
Self-citationProgress in Biomedical Polymers
(1990) · Springer eBooks · doi:10.1007/978-1-4899-0768-4 · Cited by 250
Biocompatibility of tissue analogs
Williams, D. F. (1985) · CRC Press eBooks · Cited by 184
Sequence Variation of Bovine Elastin mRNA Due to Alternative Splicing
Yeh, H., Ornstein‐Goldstein, N., Indik, Z. K., Sheppard, P. O., Anderson, N., Rosenbloom, J. C., Cicila, G. T., Yoon, K., & Rosenbloom, J. (1987) · Collagen and Related Research · doi:10.1016/s0174-173x(87)80030-4 · Cited by 146
Protein Folding: Deciphering the Second Half of the Genetic Code
Gierasch, L. M., & King, J. E. (1990) · Medical Entomology and Zoology · Cited by 101
A molecular dynamics investigation of the elastomeric restoring force in elastin
Wasserman, Z. R., & Salemme, F. R. (1990) · Biopolymers · doi:10.1002/bip.360291211 · Cited by 79
Cited by
Designing materials for biology and medicine
Langer, R., & Tirrell, D. A. (2004) · Nature · doi:10.1038/nature02388 · Cited by 3,198
Andrew MacKay, J., Chen, M., McDaniel, J. R., Liu, W., Simnick, A. J., & Chilkoti, A. (2009) · Nature Materials · doi:10.1038/nmat2569 · Cited by 580
Hydrogels as smart biomaterials
Kopeček, J., & Yang, J. (2007) · Polymer International · doi:10.1002/pi.2253 · Cited by 425
Engineering a highly elastic human protein–based sealant for surgical applications
Annabi, N., Zhang, Y.-N., Assmann, A., Sani, E. S., Cheng, G., Lassaletta, A. D., Vegh, A., Dehghani, B., Ruiz-Esparza, G. U., Wang, X., et al. (2017) · Science Translational Medicine · doi:10.1126/scitranslmed.aai7466 · Cited by 367
Chondrocytic differentiation of human adipose-derived adult stem cells in elastin-like polypeptide
Betre, H., Ong, S. R., Guilak, F., Chilkoti, A., Fermor, B., & Setton, L. A. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.05.071 · Cited by 314
Metadata
- Authors
- Urry, D. W., Parker, T. M., Reid, M. C., & Gowda, D. C.
- Venue
- Journal of Bioactive and Compatible Polymers
- Publisher
- SAGE Publications
- Published
- 1991-07
- Volume
- 6
- Issue
- 3
- Pages
- 263-282
- ISSN
- 0883-9115 (ISSN-L)
- 1530-8030
- OpenAlex
- W1966703456
- Cited by
- 269
- References
- 8
- FWCI
- 3.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Biocompatibility of the Bioelastic Materials, Poly(GVGVP) and Its γ-Irradiation Cross-Linked Matrix: Summary of Generic Biological Test Results. https://app.cochat.ai/papers/10.1177/088391159100600306
- The paper
- Urry, D. W., Parker, T. M., Reid, M. C., & Gowda, D. C. (1991). Biocompatibility of the Bioelastic Materials, Poly(GVGVP) and Its γ-Irradiation Cross-Linked Matrix: Summary of Generic Biological Test Results. Journal of Bioactive and Compatible Polymers. https://doi.org/10.1177/088391159100600306
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.