Abstract

Purpose: Severity of illness (SOI) scores are traditionally based on archival data collected from a wide range of clinical settings. Mortality prediction using SOI scores tends to underperform when applied to contemporary cases or those that differ from the case-mix of the original derivation cohorts. We investigated the use of local clinical data captured from hospital electronic medical records (EMRs) to improve the predictive performance of traditional severity of illness scoring. Methods: We conducted a retrospective analysis using data from the Multiparameter Intelligent Monitoring in Intensive Care II (MIMIC-II) database, which contains clinical data from the Beth Israel Deaconess Medical Center in Boston, Massachusetts. A total of 17 490 intensive care unit (ICU) admissions with complete data were included, from 4 different service types: medical ICU, surgical ICU, coronary care unit, and cardiac surgery recovery unit. We developed customized SOI scores trained on data from each service type, using the clinical variables employed in the Simplified Acute Physiology Score (SAPS). In-hospital, 30-day, and 2-year mortality predictions were compared with those obtained from using the original SAPS using the area under the receiver–operating characteristics curve (AUROC) as well as the area under the precision-recall curve (AUPRC). Test performance in different cohorts stratified by severity of organ injury was also evaluated. Results: Most customized scores (30 of 39) significantly outperformed SAPS with respect to both AUROC and AUPRC. Enhancements over SAPS were greatest for patients undergoing cardiovascular surgery and for prediction of 2-year mortality. Conclusions: Custom models based on ICU-specific data provided better mortality prediction than traditional SAPS scoring using the same predictor variables. Our local data approach demonstrates the value of electronic data capture in the ICU, of secondary uses of EMR data, and of local customization of SOI scoring.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/0885066615585951

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 27

Metadata

Authors
Lee, J., & Maslove, D. M.
Venue
Journal of Intensive Care Medicine
Published
2015-05-12
Volume
32
Issue
1
Pages
38-47
ISSN
  • 0885-0666 (ISSN-L)
  • 1525-1489
OpenAlex
W2392954647
Cited by
27
References
2
FWCI
3.44
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Customization of a Severity of Illness Score Using Local Electronic Medical Record Data. https://app.cochat.ai/papers/10.1177/0885066615585951
The paper
Lee, J., & Maslove, D. M. (2017). Customization of a Severity of Illness Score Using Local Electronic Medical Record Data. Journal of Intensive Care Medicine. https://doi.org/10.1177/0885066615585951

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.