The DOI matches its Crossref record.
The Efficacy of Silver-Ion Implanted Catheters in Reducing Peritoneal Dialysis-Related Infections
Abstract
♦ Background: Dialysis-related infections are the commonest cause of catheter loss and transfer to hemodialysis. Surface modifications of the catheter that reduce infections are of major importance. ♦ Objective: The efficacy of silver-ion treated catheters in reducing dialysis-related infections was tested. ♦ Methods: The study design was a prospective, randomized controlled trial. Patients were implanted with either a silver-treated study catheter or a control catheter. Prospective collection of data included infectious complications and catheter survival. ♦ Results: The subject groups were comprised of 67 silver-treated catheters and 72 control catheters. Demographic characteristics of the study and control groups were equal. Exit-site infection rates for the study group and control group (0.52 and 0.45 episodes/patient-year of dialysis respectively) were not different by Poisson regression analysis ( p > 0.4). Peritonitis rates were identical for the two groups (0.37 episodes/patient-year) and were not different by Poisson analysis ( p > 0.9). Antibiotic-free intervals between infections for the study and control groups were not significantly different for exit-site infections ( p = 0.58), peritonitis ( p = 0.44), or both infections combined ( p = 0.47). Actuarial analyses showed no differences between the groups in the probability of remaining free of exit-site infection ( p> 0.2) or peritonitis ( p > 0.7). Similarly, catheter survival was not significantly different between the groups ( p > 0.6). ♦ Conclusion: Surface modification of catheters with ion beam implantation of silver produced no clinical effect with respect to reducing dialysis-related infections.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Antimicrobial effects of silver nanoparticles
Kim, J. S., Kuk, E., Yu, K. N., Kim, J.-H., Park, S. J., Lee, H. J., Kim, S. H., Park, Y. K., Park, Y. H., Hwang, C.-Y., et al. (2007) · Nanomedicine: Nanotechnology, Biology and Medicine · doi:10.1016/j.nano.2006.12.001 · Cited by 4,918
Ferdous, Z., & Nemmar, A. (2020) · International Journal of Molecular Sciences · doi:10.3390/ijms21072375 · Cited by 1,019
Silver nanoparticles and polymeric medical devices: a new approach to prevention of infection?
Furno, F., Morley, K. S., Wong, B., Sharp, B. L., Arnold, P. L., Howdle, S. M., Bayston, R., Brown, P. D., Winship, P. D., & Reid, H. J. (2004) · Journal of Antimicrobial Chemotherapy · doi:10.1093/jac/dkh478 · Cited by 764
Silver nanoparticles are broad-spectrum bactericidal and virucidal compounds
Lara, H. H., Garza-Treviño, E. N., Ixtepan-Turrent, L., & Singh, D. K. (2011) · Journal of Nanobiotechnology · doi:10.1186/1477-3155-9-30 · Cited by 741
Antimicrobial effect of surgical masks coated with nanoparticles
Li, Y., Leung, P., Yao, L., Song, Q. W., & Newton, E. (2006) · Journal of Hospital Infection · doi:10.1016/j.jhin.2005.04.015 · Cited by 572
Metadata
- Authors
- Crabtree, J. H., Burchette, R. J., Siddiqi, R. A., Huen, I. T., Hadnott, L. L., & Fishman, A.
- Venue
- Peritoneal Dialysis International: Journal of the International Society for Peritoneal Dialysis
- Publisher
- SAGE Publications
- Published
- 2003-07
- Volume
- 23
- Issue
- 4
- Pages
- 368-374
- ISSN
- 0896-8608 (ISSN-L)
- 1718-4304
- OpenAlex
- W2101630911
- Cited by
- 225
- References
- 0
- FWCI
- 1.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Efficacy of Silver-Ion Implanted Catheters in Reducing Peritoneal Dialysis-Related Infections. https://app.cochat.ai/papers/10.1177/089686080302300410
- The paper
- Crabtree, J. H., Burchette, R. J., Siddiqi, R. A., Huen, I. T., Hadnott, L. L., & Fishman, A. (2003). The Efficacy of Silver-Ion Implanted Catheters in Reducing Peritoneal Dialysis-Related Infections. Peritoneal Dialysis International: Journal of the International Society for Peritoneal Dialysis. https://doi.org/10.1177/089686080302300410
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.