The DOI matches its Crossref record.
Heat Sterilization of Fluids for Peritoneal Dialysis Gives Rise to Aldehydes
Abstract
Objective: To chemically identify and quantify glucose degradation products in heat sterilized fluids for peritoneal dialysis. Design: Three different brands of commercial PD-fluids and one laboratory made fluid, sterilized either by heat or filtration, were investigated for the presence of aldehydes. Measurements: Aldehydes were identified and quantified using high performance liquid chromatography and gas chromatography. Results: The tested brands of heat sterilized PD-fluids were found to contain several different aldehydes while the sterile filtered PD-fluid contained none. The highest concentrations in commercial PD-fluids of these aldehydes were: acetaldehyde (420 μm), glyoxal (14 μm), methylglyoxal (12 μm) and formaldehyde (11 μm). Valeraldehyde was also identified but not quantified. The presence of 5–HMF (15 μm) and 2-furaldehyde (2 μm), which has been identified by others, was confirmed. Conclusions: The heat sterilization of commercial PD fluids gives rise to several aldehydes which may contribute to adverse effects of PD-fluids on patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Baking, Ageing, Diabetes: A Short History of the Maillard Reaction
Hellwig, M., & Henle, T. (2014) · Angewandte Chemie International Edition · doi:10.1002/anie.201308808 · Cited by 467
Dicarbonyl Intermediates in the Maillard Reaction
THORNALLEY, P. J. (2005) · Annals of the New York Academy of Sciences · doi:10.1196/annals.1333.014 · Cited by 459
Uremic Toxicity: Present State of the Art
Vanholder, R., Argilés, A., Baurmeister, U., Brunet, P., Clark, W., Cohen, G., Dedeyn, P. P., Deppisch, R., Descamps-Latscha, B., Henle, T., et al. (2001) · The International Journal of Artificial Organs · doi:10.1177/039139880102401004 · Cited by 281
Rabbani, N., & Thornalley, P. J. (2014) · Nature Protocols · doi:10.1038/nprot.2014.129 · Cited by 265
Metadata
- Authors
- Thorell, C. B. N., Muscalu, N., Andrén, A. H. G., Kjellstrand, P. T. T., & Wieslander, A. P.
- Venue
- Peritoneal Dialysis International: Journal of the International Society for Peritoneal Dialysis
- Publisher
- SAGE Publications
- Published
- 1993-07
- Volume
- 13
- Issue
- 3
- Pages
- 208-213
- ISSN
- 0896-8608 (ISSN-L)
- 1718-4304
- OpenAlex
- W2337479359
- Cited by
- 190
- References
- 0
- FWCI
- 6.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Heat Sterilization of Fluids for Peritoneal Dialysis Gives Rise to Aldehydes. https://app.cochat.ai/papers/10.1177/089686089301300309
- The paper
- Thorell, C. B. N., Muscalu, N., Andrén, A. H. G., Kjellstrand, P. T. T., & Wieslander, A. P. (1993). Heat Sterilization of Fluids for Peritoneal Dialysis Gives Rise to Aldehydes. Peritoneal Dialysis International: Journal of the International Society for Peritoneal Dialysis. https://doi.org/10.1177/089686089301300309
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.