Electric discharge machining – A potential choice for surface modification of metallic implants for orthopedic applications: A review
The DOI matches its Crossref record; 47 of the 47 references it cites were found in a registry or an index.
Abstract
Among the various metallic implant materials, titanium (Ti) alloy is the best choice for the long-term hard body tissue replacements such as hip and knee joints. It has excellent mechanical, superior biological and strong anticorrosion properties. Besides the appropriate implant material, its surface topology also plays a very important role in the success of any surgery. The surface topology is supposed to be the key factor for the promotion of osseointegration. This research article focuses its attention mainly on surface modification of Ti-based alloys by electric discharge machining process. Electric discharge machining is one of the most popular nonconventional manufacturing methods. Besides machining and surface modification of implants, it finds applications in almost all areas of manufacturing industries. This article reviews the various research work done on surface modification of Ti alloy by electric discharge machining and attempts to bring out the current scenario along with future directions. The area under focus for this research review is orthopedics applications. Furthermore, a new promising advancement in the area of enhancement of electric discharge machining performance for surface modification, particularly with regard to biocompatibility and surface quality of biomaterials, has also been introduced.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ti based biomaterials, the ultimate choice for orthopaedic implants – A review
Geetha, M., Singh, A. K., Asokamani, R., & Gogia, A. K. (2009) · Progress in Materials Science · doi:10.1016/j.pmatsci.2008.06.004 · Cited by 5,416 · cited 6×
“It is important that an implant material mimics as closely as possible the mechanical properties of the natural bone, especially elastic modulus equivalent to that of bone (5–30GPa).(2) Other properties such as hardness, tensile strength and elongation should also be kept in mind while selecting the material for impla…”
BackgroundInfluentialTitanium alloys in total joint replacement—a materials science perspective
Long, M., & Rack, H. J. (1998) · Biomaterials · doi:10.1016/s0142-9612(97)00146-4 · Cited by 3,510 · cited 2×
“Mechanical properties of metallic implant materials.(4)”
BackgroundSurface modification of titanium, titanium alloys, and related materials for biomedical applications
LIU, X., CHU, P., & DING, C. (2004) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2004.11.001 · Cited by 3,487 · cited 3×
“Surface modification techniques for titanium alloy as biomedical implant.(8)”
BackgroundMethodInfluentialOn the mechanisms of biocompatibility
Williams, D. F. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.04.023 · Cited by 2,772 · cited 1×
“The ability of an implant material to withstand an appropriate host response in a specific situation measures the biocompatibility of a material.(6)”
BackgroundState of the art electrical discharge machining (EDM)
Ho, K. H., & Newman, S. T. (2003) · International Journal of Machine Tools and Manufacture · doi:10.1016/s0890-6955(03)00162-7 · Cited by 1,729 · cited 1×
“So, vibration and chatters are almost 0, and thus, any conductive and complex shapes within very close tolerances can be machined or manufactured or modified easily.(85) Because of all these advantages, it finds applications in mold, die, automotive, aerospace and medical industries.”
BackgroundDevelopment of new metallic alloys for biomedical applications
Niinomi, M., Nakai, M., & Hieda, J. (2012) · Acta Biomaterialia · doi:10.1016/j.actbio.2012.06.037 · Cited by 1,623 · cited 1×
“So, the researcher developed biocompatible V and Al-free b-phase Ti alloy such as Ti-Nb,(12) Ti-Zr,(12) Ti-Nb-Zr,(13) Ti-Nb-Ta-Mo,(13) Ti-Nb-Ta-Sn(13) and Ti-NbTa-Zr (TNTZ) alloys to overcome the toxicity of titanium–vanadium-based alloy.(14) Very recently developed b-type Ti alloys have lower elastic modulus of 55GPa…”
MethodEnhanced Bone Apposition to a Chemically Modified SLA Titanium Surface
Buser, D., Broggini, N., Wieland, M., Schenk, R. K., Denzer, A. J., Cochran, D. L., Hoffmann, B., Lussi, A., & Steinemann, S. G. (2004) · Journal of Dental Research · doi:10.1177/154405910408300704 · Cited by 1,202
Martin, J. Y., Schwartz, Z., Hummert, T. W., Schraub, D. M., Simpson, J., Lankford, J., Dean, D. D., Cochran, D. L., & Boyan, B. D. (1995) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820290314 · Cited by 1,111
New Developments of Ti-Based Alloys for Biomedical Applications
Li, Y., Yang, C., Zhao, H., Qu, S., Li, X., & Li, Y. (2014) · Materials · doi:10.3390/ma7031709 · Cited by 1,048 · cited 2×
“To meet the joint replacement challenges, the development of various implant material has been witnessed, and the need of biomaterials is increasing rapidly.(1) The biomaterials are categorized as metallic, ceramics and polymers.”
BackgroundSpecific proteins mediate enhanced osteoblast adhesion on nanophase ceramics
Webster, T. J., Ergun, C., Doremus, R. H., Siegel, R. W., & Bizios, R. (2000) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(20000905)51:3<475::aid-jbm23>3.0.co;2-9 · Cited by 989
Metadata
- Authors
- Prakash, C., Kansal, H. K., Pabla, B., Puri, S., & Aggarwal, A.
- Venue
- Proceedings of the Institution of Mechanical Engineers, Part B: Journal of Engineering Manufacture
- Publisher
- SAGE Publications
- Published
- 2015-04-10
- Volume
- 230
- Issue
- 2
- Pages
- 331-353
- ISSN
- 0954-4054 (ISSN-L)
- 2041-2975
- OpenAlex
- W1969179886
- Cited by
- 184
- References
- 47
- FWCI
- 6.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electric discharge machining – A potential choice for surface modification of metallic implants for orthopedic applications: A review. https://app.cochat.ai/papers/10.1177/0954405415579113
- The paper
- Prakash, C., Kansal, H. K., Pabla, B., Puri, S., & Aggarwal, A. (2016). Electric discharge machining – A potential choice for surface modification of metallic implants for orthopedic applications: A review. Proceedings of the Institution of Mechanical Engineers, Part B: Journal of Engineering Manufacture. https://doi.org/10.1177/0954405415579113
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.